AQUA COASTAL AC-TC-9 T-Cell Replacement Cell Instruction Manual

October 30, 2023
AQUA COASTAL

AQUA COASTAL AC-TC-9 T-Cell Replacement Cell

AQUA-COASTAL-AC-TC-9_T-Cell-Replacement-Cell-PRODUCT

Product Information

The T-Cell Replacement Cell is a device used in pool maintenance. It is designed to work with Hayward pool systems and is manufactured by Aqua Coastal. Please note that it is not produced, manufactured, or sold by Hayward, nor is Aqua Coastal affiliated with Hayward Industries, Inc.

Installation Instructions

  1. Clean your cell before installation.
  2. Ensure that new menu settings are in place for installation.
  3. Install the replacement cell vertically.

Cleaning Instructions

To clean your cell, follow these steps:

  1. Turn off the pool pump and remove the cell from the plumbing.
  2. Use a high-pressure hose to rinse off any debris from the cell.
  3. Soak the cell in a cleaning solution for at least 30 minutes.
  4. Rinse the cell with water and re-install it.

New menu settings may be required for installation. Please refer to your Hayward pool system manual for instructions on adjusting menu settings.

INSTALLATION

The length of time your pump and filter are running each day will determine the amount of chlorine your cell will generate. Remember to adjust the output level of chlorine on your generator to compensate for an increase or decrease in daily run time on your pump and filter. This will help prevent over/under chlorination of your pool water
Example: If you double the run time on your pump and filter system then reduce your chlorination setting by half to offset it. If you triple your pump and filter run time, then reduce your chlorination settings by a factor of three to offset it. If you need to reduce your pump and filter run time, then increase your chlorination settings appropriately.

CHECK CHLORINE LEVELS

It is crucial to check your chlorine levels at least once a week during the height of swimming season. Your chlorine level should be within 1 3 ppm. After you make any chlorination settings, make sure to closely monitor the chlorine levels in the water for 2 weeks to ensure you are within this range.

LOW FLOW RATE

If you are using a variable speed pump or two speed pump, make sure to check your salt cell is receiving sufficient flow. The cell plates are located in the hump of the cell so as a precautionary measure, the replacement cell can be installed vertically or inverted to ensure it is always filled with water .AQUA-COASTAL-AC-TC-9 T-Cell-Replacement-Cell-FIG-1

CLEANING YOUR CELL

Maximize the life of your cell through regular maintenance. A clean cell will extend its life as well as producing adequate chlorine output. Failure in doing so can result in issues such as overheating and physical damage to the cell. You know it is time to clean your cell when scale on cell blades is thick enough that it touches each other between blades. Cells can be cleaned using commercial and pool grade cell cleaning solutions. Remove the cell from the housing and follow instructions on cell cleaning solution. Alternatively, a mix of 1 part hydrochloric acid and 4 parts water in a container can be used to clean the cell. The cell should take no longer than a few minutes to clean.

NOTE: New menu settings may be required for installation
The Aqua Coastal replacement cell is designed to match the performance of the Hayward TurboCell® Salt Chlorination Replacement Cell. If you are replacing an existing cell, no re configuration is necessary. If you are installing this cell on a new salt generator, you might need to re configure the generator. Failing to re configure your unit may result in system shutdown, inaccurate salt readings, and/or inadequate operation.

CONFIGUARTION REQUIRED FOR MODELS:

  • AQR (Hayward Aquarite®, any model 2009 or later) with firmware version 1.5 or later.
  • AQR PRO (Hayward Aquarite Pro®)
  • PL P 4 (Hayward ProLogicP4®)
  • PL PS X (Hayward ProLogicPS®)

CONFIGURATION NOT REQUIRED FOR MODELS:

  • AQ RITE (Hayward Aquarite®, any model 2008 or earlier with firmware earlier than 1.5)
  • AQ RITE XL (Hayward Aquarite XL®)

AQR MODELS Configuration

  1. Slide main switch to the “Auto” position
  2. Push diagnostics button until “t xx” spears on display (the default is “t 15”). If this is the model you require, then skip next part and go directly to step 4.
  3. Cell type can be changed by sliding the main switch from “Auto to “Super Chlorinate” and back to “Auto” until you see the “t xx” model required.
  4. Push diagnostics button to exit

AQR PRO MODELS Configuration

  1. Go into your settings by pushing the “Settings” button
  2. Push “>” until “Chlor.Config” is displayed, then push the “+”
  3. Push “>” repeatedly until “Cell Type” is displayed
  4. Push “+” or “–“ until the “T Cell XX” required model is displayed
  5. Now exit settings by pushing the “Info” button

PL P 4 or PL PS X MODELS Configuration

  1. Go into configuration menu
  2. Push “>” until “Chlor.Config” is displayed. Push “+”
  3. Push “>” repeatedly until “Cell Type” is displayed
  4. Push “+” or “–“ until T Cell XX” required model is displayed
  5. Now exist settings by pushing “Menu” button

Aqua Coastal salt cell is not produced, manufactured, or sold by Hayward. Aqua Coastal is not affiliated with Hayward Industries, Inc. The use of above model and system compatibility designations are included for informational purposes only.
T-CELL REPLACEMENT CELL INSTALLATION & OPERATING INSTRUCTIONS CELLULE DE REMPLACEMENT POUR T-CELL INSTRUCTIONS D’INSTALLATION ET DE FONCTIONNEMENT

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals