Ximax 1532BTU Henry Designer Radiator Installation Guide
- October 30, 2023
- XIMAX
Table of Contents
Ximax 1532BTU Henry Designer Radiator
Please read these instructions thoroughly before starting installation
Ancillary Components
1
| Blank Plug
---|---
1|
Air Vent Plug
1
| Left Bracket (a)
1|
Right Bracket (b)
4
| Coach Screw (c)
4|
Washers (d)
4
| Wall Plug (e)
4|
Bracket Buffer (f)
PLEASE CHECK THAT ALL COMPONENTS ARE PRESENT AND THAT THE PRODUCT HAS NOT SUFFERED ANY DAMAGED DURING TRANSI
Installation Instructions
This radiator is manufactured from Aluminium and it is only suitable for installation within a central heating system with a corrosion inhibitor added to the water.
Installation should be carried our by a suitably qualified professional or other fully competent person and in accordance with the relevant British and European Standards ( BS7593:1992, ENl 2828:203, ENl 2831 :2003, EN14336:2004) & all applicable Building Regulations.
When drilling or fixing into walls, floors or ceilings it is essent ial that you check for pipes and wires before commencing. Please ensure that you wear all necessary personal protective equipment.
Due to our commitment to continuous product development we reserve the right to alter specifications without notice.
Regular cleaning with a soft cloth will keep the surface of your product looking new. Soapy water can be used to remove stubborn marks. Do not use abrasive or chemical cleaners as these will damage the surface finish overtime.
- Wind a thick layer (at least 6 turns) of PTFE tape, clockwise around the radiator valve tails (not supplied) and screw the radiator valve tails into the bottom two threads and tighten firmly.
- Check that the wall is strong enough to hold the weight of the radiator filled with water. On plasterboard walls we strongly recommend fixing to the timbers.
- The bottom of the Brackets should be at least 257mm above the finished floor level so that the bottom of the radiator is at least 150mm above the finished floor level. The wide side of the Brackets should be against the wall and the fixing holes should be inwards so that the fixings cannot be seen from the side after installation. Mark the Bracket positions on the wall and then use one of the Brackets to mark the top slot positions.
- Drill the top holes in the middle of the slot markings, for the fixings you intend to use. The Wall Plugs supplied are only suitable for solid walls and you will need alternative fixings for other wall types. Screw the Brackets to the wall through the top slot and level the Brackets horizontally and vertically. Mark the bottom hole position through the Bracket and then swivel the Bracket out of the way to drill the bottom holes. Using the slot at the top allows for initial adjustment and using the hole at the bottom prevents vertical movement. Screw the bottom fixings through the bottom hole in the Bracket and tighten all 4 fixings.
- Place the plastic Bracket Buffers into the slots on the Brackets.
- Lift the radiator into position on the Brackets.
- Connect the radiator valves (not supplied) and fill the system to check for leaks. Repair any leaks as necessary.
- Flush the entire central heating system with a DWTA approved central heating cleanser, carefully following the manufacturer’s instructions.
- After thoroughly flushing the entire central heating system, refill adding a DWTA approved central heating protector, carefully following the manufacturer’s instructions.
- Run the central heating system up to full temperature and release any trapped air using the Air Vent Plug.
- Blank Plug & Air Vent Plug come installed on the radiator
VIaximum working pressure of this radiator is 10 bar. This radiator is to
be used on Domestic Central Heating Systems only:
Not s uitable for use on direct hot wate r syst ems ). Please consult your
e ngineer or supplier