SpaDealers 191RC112230E Digital Temperature Control Cool Heat 230V User Manual
- October 30, 2023
- SpaDealers
Table of Contents
- SpaDealers 191RC112230E Digital Temperature Control Cool Heat 230V
- Product Information
- Features
- Installation Instructions
- Product Usage Instructions
- Product information
- Features
- Parameters
- Installation instructions
- Assemble sensor sleeve for thermostat
- Connecting Digital Thermostat to electric heater
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SpaDealers 191RC112230E Digital Temperature Control Cool Heat 230V
Product Information
Digital Temperature Control Cool Heat 230V
The Digital Temperature Control Cool Heat 230V is a product that uses the latest technology with an LED display. It is an affordable product that is easy to operate, has solid performance, is small size and intelligent control, cooling and heating functions that suit different types of needs.
Features
- LED display
- Easy to operate
- Solid performance
- Small size
- Intelligent control
- Cooling and heating functions
Parameters
Code | Function | Setting Range | Standard Unit |
---|---|---|---|
HC | Temperature mode, options D | -40 ~ 99°C | Cooling 1~15 / Heating 2 |
D | Temperature differential | -5 ~ 5°C | |
LS | Lowest temperature setting | 0 ~ 15°C | |
HS | Highest temperature setting | 0 ~ 15°C | |
CA | Temperature calibration | ||
PT | Compressor Delay | 0 ~ 15 minutes |
Installation Instructions
Please contact your supplier for information about the use of the Digital Temperature Control Cool Heat 230V.
Product Usage Instructions
Turn On and Off
If the device is turned off, press the POWER button to turn on.
To turn it off, press and hold the POWER button for 5 seconds.
User Guide
Buttons: SET, UP, DOWN, POWER
Setting the Temperature
In normal mode, press the SET button, which then displays the current temperature, use the UP or DOWN button to adjust the temperature. Tip: Press and hold down the button UP or DOWN for rapid adjustment. When done, press SET quickly (do not hold down). The controller then returns to normal mode. Or leave it for 15 seconds, then it returns to normal mode and saves the adjustments.
Setting the Parameters
The following parameters can be set:
- Temperature differential (D)
- Lower and upper-temperature limit (LS and HS)
- Temperature calibration (CA)
- Compressor delay (PT) (Only for use with cooling / heating units)
- Conditions for startup at cooling mode (C)
- Measurement temperature = set temperature (SET) + temperature difference (d)
- Conditions for start-up in heating mode (H)
- Measurement temperature = Set Temperature Temperature Difference (d)
- Conditions for stop for cooling function
- Measurement temperature = set temperature (SET)
- Conditions for stop for heating function (H)
- Measurement temperature = set temperature (SET)
- Alarm and Error Modes
- If an alarm occurs, icons appear on the display and a beep sounds. If there is no fault on the sensor the error code alternates between displaying the temperature and the error code. If the sensor is malfunctioning, only the error code is displayed.
- The alarm on Sensor Error
- When the device is turned on, if the sensor circuit is open, the LED display will blink “__”. If there is a sensor short circuit, “HH” will appear in the display. When the sensor reports the error status, the device will work according to the following cycle: Stop 15 minutes, 15 minutes in progress.
Error Codes
Error Code | Cause | Troubleshooting |
---|---|---|
HH | Short circuit in sensor or the maximum temperature has been | |
exceeded | Check the temperature where the sensor is located and if the |
fault is due to short circuit, replace the sensor.
LL| The sensor circuit is open| Check the temperature where the sensor is
located
Product information
The product uses the latest technology with a LED display. An afforable product that is easy to operate, solid performance, small and intelligent control, cooling and heating functions that suits different types of needs.
Features
- LED display
- Button sound
- Silicone-clad buttons
- Temperature is displayed in ℃
- Cooling / heating control
Parameters
- Temperature measurement and control range: -40 ~ 99 ° C
- Relay capacity 30 A / 250 V
- Power Options: 23 0 VAC
- Input: 1 NTC sensor
- Sensor wire: 2 m (default)
- Accuracy: ± 1 ° C
- Consumption: ≤3W
- Sensor: NTC sensor (1 pc )
- Recess size: 71 × 29 (mm), product size: 77 × 34.5 × 62 (mm)
- Ambient temperature : -10 ~ 60 ° C; moisture: 20 ~ 85%
Installation instructions
- Before use, read these instructions carefully, understand the differences between the various functions nas positions. The load power must not exceed the capacity of the terminal . A nternet have to be made carefully and properly to the terminals.
- V is careful to install the unit in a protected place. It shall not be placed under the dripping water and must be kept away from electronically non Kingdom Apparate r to avoid electromagnetic interference .
- If the device is interfering, turn off the power and restart it.
- Do not open or disassemble the device under any circumstances. If any errors occur or there are questions about the use please contact your supplier.
Code | Function | Setting range | Standard | Unit |
---|---|---|---|---|
HC | Temperature mode, options | C: cooling H: heating | H | / |
D | Temperature differential | 1~15 | 2 | °C |
LS | Lowest temperature setting | -40~ | 10 | °C |
HS | Highest temperature setting | ~99 | 40 | °C |
CA | Temperature calibration | -5~5 | 0 | °C |
PT | Compressor Delay | 0~15 | 0 | Min. |
Turn on and off:
If the device is turned off, press the POWER button to turn on. To turn off, press and hold the POWER button for 5 seconds .
User guide:
Setting the temperature:
- In normal mode, press the SET button, which then displays the current temperature one, use the UP or DOWN button to adjust the temperature. Tip : Press and hold down the button UP or DOWN for rapid adjustment. When done, press SET quickly (do not hold down). The controller then returns to normal mode. Or leave it for 15 seconds, then it returns to normal mode and saves the adjustments.
Setting the parameters:
- In normal mode, press SET for 3 seconds, the indicator lights (two red dots) turn on and the controller enters maintenance mode. When the code HC appears on screen, use the UP or DOWN button to set the desired mode. H should be selected when the controller is to be used for heating and C for cooling. After adjustment, press SET to advance to the next parameter, use the same procedure to set the rest of parameters . Tip! hold down UP or DOWN for rapid adjustment. When done, press SET quickly (do not hold down). The controller then returns to normal mode. Or leave it for 15 seconds, then it returns to normal mode and saves the adjustments.
Setting the temperature differential (D):
- This selection determines the temperature at which the thermostat should turn on again after stopping. Example: If the set stop temperature set via SET is 37 ° C and D is selected to 02 then the starting temperature is the difference between these two values or 37 – 2 = 35 ° C.
Lower and upper temperature limit (LS and HS)
- LS and HS are used to set the values for the upper and lower limits of the temperature range. Example: if LS is +10, HS is +40, then the temperature can only be set between +10 and +40 ° C. If you want to set a value outside these intervals, it must be changed in LS and HS first.
Temperature calibration (CA)
- If it appears that the ambient temperature and the measured value do not match, the temperature control can be calibrated. Example: if the measured temperature shows 37 ° C but the actual is 35 ° C then CA (calibration) is set to 2 and if the actual is 37 ° C and measured 35 ° C then CA is set to -2.
- Compressor delay (PE) (Only for use with cooling / heating units)
- The controller has a delay function (PE) to protect the compressor from repeated and frequent starts and stops. PE can be set between 0-15 minutes and if PE is selected to 2, the compressor starts up only 2 minutes after the start signal from the controller. Conditions for startup at cooling mode are tremperature selected via SET + selected d (difference).
- Conditions for start-up in cooling mode (C): Measurement temperature ≥ set temperature (SET) + temperature difference (d)
- Conditions for stop for cooling function: Measurement temperature ≤ set temperature (SET)
- Conditions for stop for heating function (H): Measurement temperature = set temperature (SET)
- Conditions for start for heating function: Measurement Temperature = Set Temperature Temperature Difference (d) Alarm and error modes If an alarm occurs, icons appear on the display and a beep sounds. If there is no fault on the sensor the error code alternates between displaying the temperature and the error code. If the sensor is malfunctioning, only the error code is displayed.
- Alarm on sensor error When the device is turned on, if the sensor circuit is open, the LED display will blink “ ”, if there is sensor short circuit, “HH” will appear in the display. When the sensor reports the error status, the device will work according to the following cycle: Stop 15 minutes, 15 minutes in progress.
Alarm at maximum temperature or minimum temperature
- When the sensor measures a temperature above 99 ° C, the display shows “HH”;
- When the sensor measures a temperature below -40 ° C, LL is displayed.
Code | Cause | Troubleshooting |
---|---|---|
HH | Short circuit in sensor or the maximum temperature has been | |
exceeded | Check the temperature where the sensor is located and if the fault |
is due to short circuit, replace the sensor.
LL| The sensor circuit is open or the lowest temperature has been
dropped| Check the temperature where the sensor is located and if the fault is
due to short circuit, replace the sensor.
—| The sensor is not plugged in| Connect the sensor wires to the
terminals.
Installation procedure for TopSpa XS:
- Connect the sensor from the digital thermostat to the sensor sleeve before the filtration-/heating unit is put in place.
- If the heater has its own thermostat, adjust it to the maximum temperature.
Assemble sensor sleeve for thermostat
Connecting Digital Thermostat to electric heater
Note! Set the temperature control on the heater to max!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>