ergowerken 650805 Dual Motor Height Adjustable Table User Manual
- October 30, 2023
- ergowerken
Table of Contents
DUAL MOTOR HEIGHT ADJUSTABLE TABLE
ASSEMBLY INSTRUCTION AND USER MANUAL
650805 Dual Motor Height Adjustable Table
When tighten the screws for E , remember don’t tighten 8 screws( M6*10 ) completely , because need adjust the length according to the top size in follow step
User Manual:
Technical Specification
Input : 230VAC-110VAC
Output Power : 24VDC
Load Capacity : 1000N
Max.Speed : 35mm/s
Stroke : 650mm
Min.install dimension : 560mm
Operation Temperature : 0-40°C
Duty cycle : Max.10% or 2 min. on/18 min.off
Operating Instruction
- The individual parts must be connected before the control box is connected to the main power supply.
- The control box is connected to the main power supply, 230VAC – 120VAC. And the nixie tube shows “RST” . Press and hold the “—” button until the desk runs to its lowest point, release button, Nixie tube shows 610 Reset is finished.
- .After reset finished, keep pressing the button to move upwards and it will stop move when you release.
- Keep pressing button to move downwards and it will stop moving when you release.
- When the lifting columns stop working.,press the S button and it shows ‘5’, Then press any one button 1 or 2 or 3 to store the current table position in memory. Memory buttons 1, 2, and 3 are used to store three separate positions. It is still stored when power off. Press either 1 or 2, or 3 memory button to move the desk to the memorized position. Any stored position would be changed by simply storing a new table position over the old memorized position. You can press “*—” or “..” to stop moving in the process of moving to the position of memory.
- When the table moves upwards or downwards, if it touches hamper, it will stop and retreat a safety position.
- If two lifting columns are not synchronous, pls solve it by Reset :Press and hold the arrow button until the desk runs to its lowest point it shows RST then press the “—” arrow button again , the lifting column will go up about 5mm. Release the button , Reset finished
Note Ml has error, the display shows “ER1”
M2 has error, the display shows “ER2”
Control box keeps working on 2 mins,the display will show “HOT- ,then it will
need to cut off 18 mins to cool down. Duty protection: Continuous operation
for 3 to 4 cycles, the control box is protected, the hand control digital
display ‘HOT”, 20 minutes Alarm will be automatically disarmed Over-current
protection: When the load capacity is higher than 900N(one side), the system
will have over-current protection and shows ER3 or ER4, After 30 minutes alarm
will be disarmed Cautions
- Product use according the technical parameters.
- Please keep away from corrosive gas and dusty environment, and also pay attention to water
- Please contact our company once you have any question.
Insurance coverage
- During the warranty period (from the date of purchase within one year), and in the normal use of the product arising the failure;
- ,This product do not disassemble by yourself, otherwise will be regarded as a waiver of warranty service
Read User Manual Online (PDF format)