Intended use

This product is for lighting purposes only and:

  • may only be installed indoors / only be operated in dry rooms, i.e. not in damp rooms or rooms where there is a risk of dirt and in the area of high humidity
  • must not be exposed to strong mechanical loads or heavy soiling
  • may not be operated after damp or dirty storage until after a condition check
  • may not be changed or modified, otherwise the operating permit and conformity will expire with immediate effect! It is not allowed to remove the type plate.

If the aforementioned points are not observed, a short circuit or electric shock may occur! There is danger to life!

General safety instructions

The complete installation may only be carried out by an authorized electrician who is familiar with the applicable guidelines. Hereinafter referred to as „qualified electrician“.
For safe handling of the product, the user must have read and understood the installation/operating instructions completely before using the device for the first time.
The product may only be used if it is alright. If the device or parts of it are defective, it must be repaired by a qualified electrician.
  Only use lamps/light source approved by the manufacturer. The max. lamp wattage in watts is not allowed be exceeded.
  This product is not a toy and is not allowed be stored or used within the reach of children.
Safe operation of the product is only guaranteed if these instructions are followed. Therefore, keep these assembly/operating instructions.
SSC-LUXon GmbH accepts no liability if the instructions given here are not followed or the lamp is subjected to improper use.

Assembly & configuration

Caution: The connecting cable must be disconnected from the power supply before starting work (switch off the main switch/fuse)! Only use
parts which are supplied with the product or which are clearly marked as equipment! Otherwise the product may not be sufficiently safe!
When drilling, pay attention to cables and gas and water lines.

Assembly location

The product is suitable for mounting on ceilings and walls. The product may only be mounted on a stable, tilt-resistant and level surface. Do not cover the product under any circumstances, especially not with insulating material! Fire hazard!
Components of the luminaire and especially the lamps/light source become hot during operation. Especially in the case of halogen lamps/ light source. Keep a sufficient distance (0.5 m) from easily flammable objects (e.g. curtains, drapes, etc.) and flammable materials (ignition temperature<250°C).

Operation, bulb replacement, faults & disorders

Caution: Disconnect the connecting cable from the power supply before replacing lamps/light sources! Do not cover! Covering with (e.g. towel) is a fire hazard! Luminaires with protective cover may only be operated with complete protective cover!
Never look directly into the light source!

Avoidance of disturbances and fire hazards:
It is not allowed to cover the product under any circumstances. Air circulation must be ensured. Nothing may be attached or hung on the product, especially no decoration.

Cleaning & care instructions

The product may only be wiped dry or carefully with a slightly damp and lint- free cloth. The product is not allowed to be removed for this purpose. Do not use abrasive or sharp objects or aggressive cleaning agents. Do not use solvents.

Technical data & assembly instruction model TOBI-S & TOBI-L

TOBI-S

TOBI-L

Can only be used indoors

  1. Disconnect the connecting cable from the power  supply!
  2. Remove the base plate (towards the ceiling/wall) from the enclosure by turning the base plate anti-clockwise.
  3. Mark the drill holes with the help of the base plate. Drill the holes in the ceiling and insert the dowels. Pay particular attention to the position of the thread on the TOBI-L model so that the lights all face in the same  direction later.
  4. Guide the connection cable through the large opening in the base plate and fix the base plate with the screws in the intended position.
  5. Connect L & N of the connecting cable to the connecting terminal / luster terminal.
  6. Turn the front ring (light direction) off by turning the ring counterclockwise.
  7. Screw the luminaire body onto the base plate mounted on the ceiling.
  8. Screw the GU10 light source into the socket. Insert the light source into the luminaire. Then screw the front ring back onto the lamp.
  9. Switch on the voltage again. The product is now ready for operation.
Type: Ceiling/wall light
Models: TOBI-S 990070782, 990070784

TOBI-L 990070781, 990070783
Protection type:| IP20
Voltage:| 230 VAC
Material:| Aluminium
Socket:| GU10
Max. power:| 15 W
Operating temperature:| -5°C – +40°C
Protection class| II
Measurements:| TOBI-S: Ø 60 mm / height 85 mm
TOBI-L: Ø 56 mm / height 160 mm
Swivelling:| 90° (only model TOBI-L)
Colour:| White or black

Notes / Explanations & Legend

The following applies to all models

| Disconnect the device from the mains power before starting any work
---|---
| Protection class II
| Installation only by qualified electrician
| Distance to illuminated objects min. 0.5m
| Vers. 06/2020

Notes on use indoors & outdoors

Protection type IP20 & IP23: Use only indoors and dry, i.e. do not use in damp or dirty rooms and in areas of high humidity.
 Protection type IP44 & IP65: Can be used\  indoors and outdoors.

Online shop:
www.led-lichtraum.de

Satisfied with your product?
Then we look forward to your  product review in our online store, on Amazon or eBay.

Disposal instructions

Make sure to dispose packaging in accordance  with the applicable guidelines of your local authority. Devices marked with the crossed-out waste garbage do not belong in the household waste!
You are obliged to hand in these devices at one of the free collection points in your municipality. You can obtain more information from your local authority, the relevant town hall or a local or regional waste disposal company.

Keep packaging material and small parts away from children and animals. Danger of suffocation!

TOBI-S 990070782, 990070784

TOBI-S 990070782, 990070784

TOBI-L 990070781, 990070783

TOBI-L 990070781, 990070783

Customer Support

SSC-LUXon GmbH – Am Krozinger Weg 4, 79189 Bad Krozingen, Germany
E-Mail: [email protected];
Phone: +49 7633 – 988 3000

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SSC-LUXon User Manuals

Related Manuals