SCHWAIGER NWST811 Network Connector Cat8.1-STP Metal Instruction Manual
- June 10, 2024
- Schwaiger
Table of Contents
SCHWAIGER NWST811 Network Connector Cat8.1-STP Metal Instruction Manual
MOUNTING INSTRUCTIONS
For RJ45 plugs, metal, without tools
Suitable for network cables from Ø 6 mm up to max. 8 mm if the cable outer sheath should reach below the strain relief, otherwise up to 9.5 mm.
Pin assignment | TIA/EIA T568A | TIA/EIA T568B | |
---|---|---|---|
12 | white/green green | white/orange orange | |
34 | white/orange blue | white/green blue | |
56 | white/blue orange | white/blue green | |
78 | white/brown brown | white/brown brown |
Please use the Schwinger network cable NWKU80xx 051.
-
Remove the screw socket 1 (= strain relief) before mounting.
-
Feed the cable through the screw socket in the specified direction and remove the outer sheath 2 of the cable over a length of approx. 20-25 mm. Fold back the braid (and if necessary, the drain wire)
-
For S/FTP cables, remove the foil shield 3 which surrounds each wire pair. If there is a yarn strength member 4 in the middle of the cable, remove it.
-
Disentangle the wire pairs. Make sure it remains clear which wires belong together as a pair, so the wires can be connected correctly later (the connector block 5 is marked with the colors for TIA/EIA T568A and B). Insert the wires in the corresponding recesses 6 of the connector block. Cut the protruding ends of the wires 7 with a suitable tool.
-
Press the prepared connector block 5 into the actual plug housing 8 until it stops. This can only be done in one position; you cannot slide the block incorrectly into the plug housing.
-
Close the plug housing (if necessary, with the help of suitable pliers) and screw the screw socket / strain relief 1 to the plug housing.