Lexing LX-MV-360S8-A Microwave Sensors Instructions
- June 10, 2024
- Lexing
Table of Contents
Lexing LX-MV-360S8-A Microwave Sensors
Product Information
The LX-MV-360S8-A Microwave Sensor is a device that detects motion using microwave technology. It is designed to be used in indoor settings and is ideal for use in homes, offices, and other buildings. The sensor operates on a power source of 100-130V/AC or 220-240V/AC and has a power frequency of 50/60Hz. It has a transmission power that allows it to detect motion within a 360-degree range.
Product Usage Instructions
- Before installing the LX-MV-360S8-A Microwave Sensor, ensure that the power source is switched off.
- Choose a location to install the sensor. It should be mounted on a flat surface and should not be obstructed by any objects.
- Connect the wires from the power source to the sensor according to the wiring diagram provided in the user manual.
- Adjust the sensitivity of the sensor using the adjustment knob. This will determine how sensitive the sensor is to motion.
- Test the sensor by walking within its detection range. If it does not detect motion, adjust the sensitivity until it does.
- The LX-MV-360S8-A Microwave Sensor is now ready for use.
Dimension
Specifications
- Power source: 100-130V/AC
- 220-240V/AC
- Power frequency: 50/60Hz
- Transmission power: <0.2mW
- Rated load:
- 1200W/5A,Max,tungsten(cosφ=1)(220-240V/AC) 300W/2.5A,Max,fluorescent(cosφ=0.5)(220-240V/AC) 600W/5A,Max,tungsten(cosφ=1)(100-130V/AC)
- 150W/2.5A,Max,fluorescent(cosφ=0.5)(100-130V/AC)
NOTE: the high-frequency output of this sensor is <0.2mW- that is just one 5000 of the transmission power of a mobile phone or the output of a microwave oven.
Sensor information
- HF system: 5.8GHz CW electric wave,ISM band
- Detection angle : 360°
- Detection range: 2m-5m-10m(radii.) (adjustable)
- Time setting:
- 12sec±3sec/3min±1min/15min±2min/30min±3min (adjustable) Light-control: 10LUX-100LUX-500LUX-2000LUX (adjustable) Installation sit: indoors, ceiling mounting
- Working temperature: – 15°C~+70°C
- Power consumption : approx.0.5W
Utilizing field and introduction
- LX-MV-360S8 is a moving object sensor that can detect range of 360°and it’s working frequency is 5.8G.The advantage of this product is stable working state (stable working temperature: -15°C~+70°C), LX-MV-360S8 adopts a microwave sensor(high-frequency output<0.2mW),so that it is safe and performs better than infrared sensor.
Installation
- Through the buckle under cover(seefig.1)(fig2)
- Hold base against the Ceiling and mark drill holes, paying attention to any existing wiring in the Ceiling;
- Drill the holes, insert wall plugs (6mm dia.);(see fig.4);
- Put the power wire and load wire through the base holes(seefig.5); 5.Cover cover into buckle(seefig.6);
Parameter setting
Shown as chart below: By setting the S1, S2, S3, S4, and S5 to set the delay time of products, by setting S6, S7 to set the detection range of products, by setting the S8, S9, S10 to set the light-control of products .
Detection range setting (sensitivity)
Detection range is the term used to describe the radii of the more or less circular detection zone produced on the ground after mounting the sensor light at a height of 2.5m, pull switch to the ON position as “1”, pull switch to the OFF position as “0”, switch location and detection range of the corresponding table is as follows:
S1 | S2 | Detection range |
---|---|---|
0 | 0 | 2m |
0 | 1 | 5m |
1 | 0 | 10m |
- NOTE: the above detection range is gained in the case of a person who is between 1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if person’s stature, figure and moving speed change, the detection distance will also change.
- ATTENTION: When use this product, please adjust the sensitivity to an appropriate position you need, please do not adjust the sensitivity to maximum, to avoid the product does not work normally caused by wrong motion.Because the sensitivity is too high easily detect the wrong motion by wind blowing leaves & curtains, small animals, and the wrong motion by interference of power grid & electrical equipment. All those lead the product does not work normally !
- When the product does not work normally, please try to lower the sensitivity appropriately, and then test it.
Time setting
- The light can be set to stay ON for any period of time between 12±3sec and a maximum of 30±3min. Any movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time for adjusting the detection zone and for performing the walk test.
- Pull switch to the ON position as “1”, pull switch to the OFF position as “0”, switch location and time setting of the corresponding table is as follows:
S3 | S4 | S5 | Time setting |
---|---|---|---|
0 | 0 | 0 | 30min ± 3min |
0 | 0 | 1 | 15min ± 2min |
0 | 1 | 0 | 3min ± 1min |
1 | 0 | 0 | 12sec ± 3sec |
NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start detecting movement again. The light will only switch on in response to movement once this period has elapsed.
Light-control setting
The chosen light response threshold can be infinitely from approx. 10-2000LUX,
pull switch to the ON position as “1”, pull switch to the OFF position as “0”,
switch location and light-control of the corresponding table is as follows:
S6 | S7 | S8 | Light-control |
---|---|---|---|
0 | 0 | 0 | 10LUX |
0 | 0 | 1 | 100LUX |
0 | 1 | 0 | 500LUX |
1 | 0 | 0 | 2000LUX |
Warning! The following situation will lead to misoperation
- Being installed in the rocking object will lead to misoperation.
- The shaking curtain which is blown by wind will lead to misoperation, please select the suitable installed place.
- Being installed in the place where the traffic is busy will lead to misoperation.
- It will lead to misoperation when there are sparks produced by some equipment nearby.
Troubleshooting
Malfunction | Cause | Remedy |
---|---|---|
The load will not work | · wrong light-control setting selected | · Adjust |
setting
· load faulty| · Change load
· mains switch OFF| · Switch ON
The load work always| · continuous movement in the detection
zone
| · Check zone setting
The load work without any identifiable movement| · The sensor
not mounted for detecting
movement reliably
| · Securely mount the enclosure
· movement occurred, but not identified by the sensor(movement behind wall,
movement of a small object in immediate
lamp vicinity etc.)
| · Check zone setting
The load will not work despite movement| ·rapid movements are being suppressed
to minimize malfunctioning or the detection zone you have set is too small
| · Check zone setting
Warning
- The detection distance may multiply for the reflection on microwave electromagnetic field by the metal or glass materials. Thus, lower the sensitivity to reach the appropriate detection distance. Never turn the SENS knob to the maximum value to avoid error detection. Also the surrounding environment will lead to error action, e.g. the automobiles passing by or the wandering objects caused by the wind. Products should be installed more than 4 meters one from the other, otherwise the interference among them will cause error action.
- The proper use of trimming potentiometer: the trimming potentiometer is used to adjust the time that sensor light turn on when detects somebody movement and turn off automatically. The user can adjust the light time according to different needs. In order to carry out the saving-energy effectively,we suggest that we should decrease the close time automatically.In addition, due to the continuous sensor function of the microwave sensor lamp,simply speaking:Timer will time renewedly so as sensor lamp has any induction. Lamp will keep open once detected movement within the detection range .
- Please confirm with prefessional installation.
- Please cut off power supply before installation and removal operations.
- Make sure that you have cut off the power for safety purposes.
- Improper operation caused losses, the manufacturer does not undertake any responsibility.
- We are committed to promoting the product quality and reliability, however, all the electronic components have certain probabilities to become ineffective, which will cause some troubles.When designing, we have paid attention to redundant designs and adopted a safety quota to avoid any troubles.
- This instruction, without our permission, should not be copied for any other purposes.
- All manuals and user guides at all-guides.com
Documents / Resources
|
Lexing LX-MV-360S8-A Microwave
Sensors
[pdf] Instructions
LX-MV-360S8-A Microwave Sensors, LX-MV-360S8-A, Microwave Sensors, Sensors
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>