PENTAIR USFRC-FF-3000-QC-1 Easy Flow Under Counter Water Filtration System Instruction Manual
- June 10, 2024
- Pentair
Table of Contents
- PENTAIR USFRC-FF-3000-QC-1 Easy Flow Under Counter Water Filtration
- PRODUCT SPECIFICATIONS
- TOOLS REQUIRED FOR INSTALLATION
- PRECAUTIONS
- INSTALLATION INSTRUCTIONS
- FILTER REPLACEMENT INSTRUCTIONS
- PERFORMANCE DATA
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 1 size Phillips screwdriver (supplied)
PENTAIR USFRC-FF-3000-QC-1 Easy Flow Under Counter Water Filtration
System
Thank you for your purchase. The Pentair® Easy Flow Under Counter Water Filtration System makes getting the water you want easier than ever. It effectively reduces contaminants so you can enjoy peace of mind with every refreshing sip, straight from your existing faucet. And you can install it yourself in minutes.
PRODUCT SPECIFICATIONS
- Temperature Range: 40 – 100°F (4.4 – 37.8°C)
- Min.-Max. Working Pressure: 40-125 psi (2.75 – 8.62 bar)
- Service Flow Rate @ 60 psi: Up to 2.2 gpm* (8.33 Lpm)
- Rated Service Life: Dimensions (w/o hoses): 3000 gallons (11356 liters)
- Connection Type: Weight: 14.86” (H) x 4.8” (D) 377.44 mm (H) x 101.09 mm (D)
- Connection Type: 3/8” (.375 mm) compression
- Weight: 3.3 lbs (1.5 kg)
Not Performance Tested or Certified by NSF
See Performance Data on page 6 for further performance and specification
information and at www.nsf.org.
TOOLS REQUIRED FOR INSTALLATION
-
1 size Phillips screwdriver (supplied)
- Two wrenches (supplied)
- Flashlight or light source (optional)
- Towel or shallow tray (optional)
Note: Typical installation of the Easy Flow takes 15 minutes or less.
PRECAUTIONS
WARNING: Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected waters that
may contain filterable cysts. Check for compliance with state and local laws
and regulations.
CAUTION: Filter must be protected against freezing, which can cause
cracking of the filter and water leakage.
NOTE
- For cold water use only.
- The system must be maintained according to manufacturer’s recommendations, including replacement of filter. The contaminants or other substances removed or reduced by this water treatment device are not necessarily in your water. Ask your local water municipality for a copy of their water analysis or have your water tested by a reputable water-testing lab.
- After prolonged periods of non-use (such as during a vacation), it is recommended that the system be flushed thoroughly. Let the water run for a minimum of fifteen (15) minutes before use.
- The filter used with this system has a limited service life. Changes in taste, odor or flow may indicate that the filter should be replaced.
INSTALLATION INSTRUCTIONS
Please read all instructions, specifications and precautions before proceeding
with installation of the system.
To access a digital version of the user’s guide and other resources, or for
filter reorder information, scan the QR code located on the top of the filter
(see below).
NOTE: There must be a shutoff valve installed ahead of the system. The filter and base are factory assembled and do not need to be disassembled until replacement of the filter is required.
-
With supplied #1 size Phillips screwdriver, remove screw from black battery cover on bottom of unit (see below). Unlatch cover and install the two AA batteries included with your system ensuring that the + (plus) and – (minus) terminals
are aligned correctly. Replace cover and screw tight. Lights will blink and go through light sequence. See “Filter Life Indicator” section on page 4. -
Shut off the cold water to your faucet by turning the cold water valve under the sink, clockwise.
-
Turn on cold water faucet to release pressure and drain water until water stops. Leave faucet open.
NOTE: If the filter is removed from the unit for any reason, filter must be re-installed. An audible click ensures proper sealing of the filter. -
Place a tray or towel under the cold-water line to catch excess water. With wrench, disconnect cold-water hose from cold-water line located near the water shutoff valve (do NOT disconnect from the faucet).
-
Connect system cold-water inlet hose (white) to the cold-water shutoff valve. Ensure tight connection (typically five [5] turns).
-
Connect cold-water outlet hose (blue) to the cold-water hose still connected to the faucet. Use a supplied wrench to hold the current hose fitting while using the second supplied wrench to tighten the fitting on the blue hose.
Top View -
PLACING THE SYSTEM INTO OPERATION
-
Wipe down system and area so it is dry, and to more easily identify potential system leaks. Slowly open the water shutoff valve, by turning counter-clockwise, while visually inspecting fitting tightness to ensure no leaks.
-
Allow water to flow with faucet open completely for fifteen
(15) minutes to flush the filter.
NOTE: A drinking water filter may contain carbon fines (very fine black particles). If carbon fines appear in the water, continue flushing until none are present.Initially, filtered water may appear cloudy. If cloudiness in glass of water rises to the top, the cause is likely due to air in the water. The air (and cloudiness) will disappear within a few weeks after installation. -
Press and hold small Filter Life Indicator Button for five (5) seconds. After the button is released, a blue light on the Filter Life Indicator will flash four (4) times to confirm timer has started.
FILTER LIFE INDICATOR
To check the remaining life of your filter, push Filter Life Indicator Button.
Blue Light:
Each blue light flash indicates three (3) months of remaining filter life
(e.g. two [2] flashes represent six [6] months remaining life).
Red Light:
When the filter needs to be changed, a red light will blink three (3) times,
continuing three (3) times daily for eight (8) seconds for a period of 60
days, unless deactivated by pressing the Filter Life Indicator Button.
If red and blue lights are flashing alternately, batteries need to be
replaced.
After replacing filter, press and hold the Filter Life Indicator Button for five (5) seconds. The blue lights will flash four (4) times to indicate remaining life of new filter.
FILTER REPLACEMENT INSTRUCTIONS
-
Shut off the cold water to your faucet by turning cold-water valve, under the sink, clockwise.
-
Turn on cold water faucet to release pressure and to drain water from hose.
-
Press and hold Filter Release Button while holding firmly on the base. Pull up on the exhausted filter to remove.
-
Insert the new filter into base of the Easy Flow Water Filtration System. An audible click ensures proper sealing of the filter.
-
Open water shutoff valve by turning counter-clockwise.
-
Allow water to flow with faucet open completely for fifteen
(15) minutes to flush the filter.
NOTE: A drinking water filter may contain carbon fines (very fine black particles). If carbon fines appear in the water, continue flushing until none are present.Initially, filtered water may appear cloudy.
If cloudiness in glass of water rises to the top, the cause is likely due to air in the water. The air (and cloudiness) will disappear within a few weeks after installation. -
Press and hold small Filter Life Indicator Button for five (5) seconds. A blue light on the Filter Life Indicator will flash four
(4) times to confirm timer has started.
PERFORMANCE DATA
Pentair Easy Flow Replacement Filter
RC-LCT Filter……….Part No: USFRC-FF-3000-QC-1
Replacement filters may be ordered by visiting
pentair.com/easyflow, which can be reached by
scanning the QR label on the product.
While testing was performed under laboratory conditions, actual performance
may vary.
CERTIFIED PERFORMANCE CLAIMS
This system has been tested in accordance to NSF/ANSI 42 and 53 for the
reduction of the substances listed below. The concentration of the indicated
substance in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42 and 53.
Substance
|
Influent Challenge Concentration
| Maximum Permissible Product Water|
Reduction Requirements
|
Average Reduction
---|---|---|---|---
Standard 42
Chlorine Taste & Odor|
2.0 mg/L ± 10%
|
–
|
≥50%
|
79.7%
Standard 53
Cyst†
| Minimum 50,000
Microsphere/L
|
n/a
|
≥99.95%
|
99.99%
Lead (pH 6.5)| 0.15 mg/L ± 10%| 0.005 mg/L| n/a| 97.7%
Lead (pH 8.5)| 0.15 mg/L ± 10%| 0.005 mg/L| n/a| 99.5%
Perfluorooctanoic Acid (PFOA) and Perfluorooctane Sulfonate (PFOS)|
0.0015mg/L
+/- 10%
|
0.00007 mg/L
|
n/a
|
98.36%
*Tested using flow rate =2.2 gpm; pressure = 60 ± 3 psig; pH = 7.5 ± 0.5; temp = 20° ± 3°C
†NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by mechanical means.
EPA Est. No. 090375-MEX-001
Rated Capacity: | 3,000 gallons (11,356 liters)/1-year |
---|---|
Feed Pressure Range: | 40 – 125 psi (2.75 – 8.62 bar) |
Temperature Range: | 40 – 100°F (4.4 – 37.8°C) |
Rated Service Flow: | 60 psi: 1.4gpm (5.3 Lpm) |
System Tested and Certified by NSF International against NSF/ANSI Standards 42 and 53 for the reduction of the claims specified in the Performance Data Sheet and at www.nsf.org.
Easy Flow is certified by IAPMO R&T against NSF/ANSI 53 for the reduction of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS).
PENTAIR OMNIFILTER UNDER COUNTER WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS
18345 BISHOPS DR., SUITE 200, BROOKFIELD, WI 53005 USA
P: 262.238.4400 | PENTAIR.COM
CUSTOMER CARE: 800.279.9404 | tech-support@pentair.com
©2022 Pentair. All rights reserved.
All indicated Pentair trademarks and logos are property of Pentair.
Third party registered and unregistered trademarks and logos are the property
of their respective owners.
References
- FreshPoint Easy Flow Under Counter Filtration System | Pentair
- NSF | The Public Health and Safety Organization
Read User Manual Online (PDF format)