Altronix AL624 Linear Power Supply-Charger Instruction Manual
- June 11, 2024
- Altronix
Table of Contents
Altronix AL624 Linear Power Supply-Charger
Overview
Altronix AL624 linear power supply/charger converts low voltage AC input into 6VDC or 12VDC @ 1.2A or 24VDC @ 750mA of continuous supply current (see specifications). This general purpose power supply has a wide range of applications for access control, security, and CCTV system accessories that require additional power.
Specifications
Input:
- 16VAC to 24VAC, 20VA to 40VA (Transformer Selection Table).
Output:
- Switch selectable 6VDC-12VDC-24VDC.
- 6VDC or 12VDC @ 1.2A or 24VDC @ 0.75A supply current.
- Filtered and electronically regulated output.
- Short circuit and thermal overload protection.
Battery Backup:
- Built-in charger for sealed lead acid or gel type batteries.
- Automatic switch over to stand-by battery when AC fails.
- Maximum charge current 0.3A.
- PTC battery protection.
Visual Indicators:
- AC input and DC output LED indicators.
Features:
- Extremely compact design.
- Battery leads included.
- Snap Trac compatible (order Altronix model #ST3).
- DIN Rail mount version available
(order Altronix model #DPS1).
Board Dimensions (L x W x H approx.):
3” x 2.5” x 1.125” (76.2mm x 63.5mm x 28.6mm).
Voltage Output
Transformer Selection Table:
Output | Voltage Selector (JMPR) | Transformer |
---|---|---|
12VDC @ 1.2A | Leave J1 and J2 Intact | 16.5VAC / 20VA |
(Altronix model TP1620)
24VDC @ 750mA| Cut Jumper J1 Only| 24VAC / 40VA
(Altronix model TP2440)
6VDC @ 1.2A| Cut Jumper J2 Only| 12VAC / 20VA
(Altronix model TP1220)
Installation Instructions
-
Mount AL624 in the desired location/enclosure (mounting hardware included).
-
Unit is factory set for 12VDC. For 6VDC output cut jumper J2, for 24VDC output cut Jumper J1.
-
Connect proper transformer to the terminals marked [AC] (refer to Voltage Output/Transformer Selection Table).
Use 18 AWG or larger for all power connections (Battery, DC output). -
Measure output voltage before connecting devices. This helps avoiding potential damage.
-
Connect devices to be powered to the terminals marked [+ DC] and [DC – BAT], carefully observing polarity.
-
Connect battery to the terminals marked [BAT +] and [DC – NEG] (battery leads included)
Note: To avoid damage connect batteries as follows:- For 6VDC operation connect one (1) 6VDC battery.
- For 12VDC operation connect one (1) 12VDC battery or two (2) 6VDC batteries wired in series.
- For 24VDC operation connect two (2) 12VDC batteries wired in series.
Note: When batteries are not used, a loss of AC will result in a loss of output voltage.
LED Diagnostics
Red (DC) | Green (AC) | Power Supply Status |
---|---|---|
ON | ON | Normal operating condition. |
ON | OFF | Loss of AC. Stand-by battery supplying power. |
OFF | ON | No DC output. Short circuit or thermal overload condition. |
OFF | OFF | No DC output. Loss of AC. Discharged or no battery present. |
Terminal Identification
Terminal Legend | Function/Description |
---|---|
AC / AC | Low voltage AC input (refer to voltage output/transformer selection |
table).
+ DC –| 6VDC-12VDC @ 1.2A continuous supply current or 24VDC @ 750mA
continuous supply current.
– BAT +| Stand-by battery connections. Maximum charge rate 300mA.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone:
718-567-8181 | fax:
718-567-9056
website: www.altronix.com
e-mail: info@altronix.com | Lifetime Warranty
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>