Pacer TAE4-38R-2 Tinned Lug User Guide

June 11, 2024
Pacer

Lugs
User Guide

TAE4-38R-2 Tinned Lug

Lugs and splices are connection points that are created by crimping the connector onto a wire or cable. This connection, commonly referred to as a cold weld, creates a solid, long-lasting connection. Pacer lugs and splices are made from 100% pure copper for high conductivity.
This copper is fully annealed to prevent cracking while being crimped and while in service. These terminals are also tin plated to prevent corrosion. Many of these Lugs are general purpose seamless electrical terminals. They are commonly used with battery cable.

Pacer is a Proud Member of:

Pacer TAE4-38R-2 Tinned Lug - icon

Construction

Tin plated copper with no exposed seams offering 100% long term conductivity

Benefits

| Tinned copper
---|---
| Highly durable
| Multitude of sizes
| Easily terminated
| In-field applications
| Long-lasting

Compliances

Pacer TAE4-38R-2 Tinned Lug - fig 1

| E.T.P. (Electrolytic Tough Pitch) CDA-110
---|---
| ASTM-B-152 Copper
| RoHS Compliant
| CSA Approved
| UL Approved

TINNED CLOSED END LUGS

WIRE AWG| STUD
SIZE| PART
NUMBER| LENGTH
(Inches)| WIDTH
(Inches)| CLEARANCE
(Inches)| PACKAGE SIZE
---|---|---|---|---|---|---
8 AWG| #10| TAE8-10R| 1.187| 0.438| 0.344| 4, 25, 100, 250
| 1/4″| TAE8-14R| 1.187| 0.438| 0.344| 4, 25, 100, 250
5/16″| TAE8-56R| 1.187| 0.438| 0.344| 4, 25, 100, 250
3/8″| TAE8-38R| 1.344| 0.609| 0.406| 4, 25, 100, 250
1/2″| TAE8-12R| 1.484| 0.766| 0.469| 4, 25, 100, 200
6 AWG| #10| TAE6-10R| 1.266| 0.438| 0.344| 4, 25, 100, 250
| 1/4″| TAE6-14R| 1.266| 0.438| 0.344| 4, 25, 100, 250
5/16″| TAE6-56R| 1.266| 0.438| 0.344| 4, 25, 100, 250
3/8″| TAE6-38R| 1.406| 0.609| 0.406| 4, 25, 100, 250
1/2″| TAE6-12R| 1.688| 0.766| 0.469| 4, 25, 100, 200
4 AWG| #10| TAE4-10R| 1.5| 0.531| 0.406| 4, 10, 50, 200
| 1/4″| TAE4-14R| 1.5| 0.531| 0.406| 10, 50, 200
5/16″| TAE4-56R| 1.5| 0.531| 0.406| 4, 10, 50, 200
3/8″| TAE4-38R| 1.688| 0.531| 0.406| 4, 10, 50, 200,800
1/2″| TAE4-12R| 1.625| 0.766| 0.469| 4, 10, 25, 100
2 AWG| 1/4″| TAE2-14R| 1.625| 0.609| 0.406| 4, 10, 25, 100
| 5/16″| TAE2-56R| 1.625| 0.609| 0.406| 4, 10, 25, 100
3/8″| TAE2-38R| 1.625| 0.609| 0.406| 4, 10, 25, 100,400
1/2″| TAE2-12R| 1.75| 0.766| 0.406| 4, 10, 25, 100
1 AWG| 1/4″| TAE1-14R| 1.719| 0.692| 0.406| 4, 10, 25, 100
| 5/16″| TAE1-56R| 1.719| 0.692| 0.406| 4, 10, 25, 100
3/8″| TAE1-38R| 1.719| 0.692| 0.406| 4, 10, 25, 100
1/2″| TAE1-12R| 1.719| 0.692| 0.469| 4, 10, 25, 100
1/0 AWG| 1/4″| TAE1/0-14R| 1.844| 0.734| 0.406| 4, 10, 25, 100
| 5/16″| TAE1/0-56R| 1.844| 0.734| 0.406| 4, 10, 25, 100
3/8″| TAE1/0-38R| 1.844| 0.734| 0.406| 4, 10, 25, 100,400
1/2″| TAE1/0-12R| 1.844| 0.734| 0.469| 4, 10, 25, 100
2/0 AWG| 1/4″| TAE2/0-14R| 2.063| 0.813| 0.5| 4, 10, 25, 50
| 5/16″| TAE2/0-56R| 2.063| 0.813| 0.5| 4, 10, 25, 50
3/8″| TAE2/0-38R| 2.063| 0.813| 0.5| 4, 10, 25, 50, 200
1/2″| TAE2/0-12R| 2.063| 0.813| 0.5| 4, 10, 25, 50
3/0 AWG| 1/4″| TAE3/0-14R| 2.172| 0.906| 0.5| 4, 10, 25
| 5/16″| TAE3/0-56R| 2.172| 0.906| 0.5| 4, 10, 25, 50
3/8″| TAE3/0-38R| 2.172| 0.906| 0.5| 4, 10, 25, 50
1/2″| TAE3/0-12R| 2.172| 0.906| 0.5| 4, 10, 50
4/0 AWG| 1/4″| TAE4/0-14R| 2.344| 0.984| 0.547| 4, 10, 25
| 5/16″| TAE4/0-56R| 2.344| 0.984| 0.547| 4, 10, 25
3/8″| TAE4/0-38R| 2.344| 0.984| 0.547| 4, 10, 25

→ Multiple Sizes and Styles to Handle any Projects or Applications.
→ Built for Rugged Durability and Longevity in Harsh Conditions.

Pacer TAE4-38R-2 Tinned Lug - Styles to Handle

BRAZED SEAM TINNED LUGS

WIRE AWG| STUD
SIZE| NONINSUL.
P/N| NYLON INSUL. P/N| COLOR| LENGTH
(Inches)| PAD WIDTH
(Inches)| PACKAGE SIZE
---|---|---|---|---|---|---|---
8 AWG| #10| TL8-10R| TLNF8-10R| RED| 0.96| 0.374| 4, 25, 100, 250
| 1/4″| TL8-14R| TLNF8-14R| RED| 0.96| 0.374| 4, 25, 100, 250
5/16″| TL8-56R| TLNF8-56R| RED| 1.007| 0.374| 4, 25, 100, 250
3/8″| TL8-38R| TLNF8-38R| RED| 1.136| 0.583| 4, 25, 100, 250
1/2″| TL8-12R| TLNF8-12R| RED| 1.432| 0.81| 4, 25, 100, 250
6 AWG| #10| TL6-10R| TLNF6-10R| BLUE| 1.215| 0.48| 4, 25, 100, 250
| 1/4″| TL6-14R| TLNF6-14R| BLUE| 1.215| 0.48| 4, 25, 100, 250
5/16″| TL6-56R| TLNF6-56R| BLUE| 1.215| 0.48| 4, 25, 100, 250
3/8″| TL6-38R| TLNF6-38R| BLUE| 1.296| 0.643| 4, 25, 100, 250
1/2″| TL6-12R| TLNF6-12R| BLUE| 1.479| 0.825| 4, 25, 100, 250
4 AWG| #10| TL4-10R| TLNF4-10R| YELLOW| 1.288| 0.475| 4, 10, 50, 100
| 1/4″| TL4-14R| TLNF4-14R| YELLOW| 1.288| 0.475| 4, 10, 50, 100
5/16″| TL4-56R| TLNF4-56R| YELLOW| 1.288| 0.475| 4, 10, 50, 100
3/8″| TL4-38R| TLNF4-38R| YELLOW| 1.385| 0.665| 4, 10, 50, 100
1/2″| TL4-12R| TLNF4-12R| YELLOW| 1.385| 0.665| 4, 10, 50, 100
2 AWG| 1/4″| TL2-14R| –| –| 1.578| 0.63| 4, 10, 25, 100
| 5/16″| TL2-56R| –| –| 1.578| 0.63| 4, 10, 25, 100
3/8″| TL2-38R| –| –| 1.578| 0.63| 4, 10, 25, 100
1/2″| TL2-12R| –| –| 1.695| 0.864| 4, 10, 25, 100
1/0 AWG| 1/4″| TL1/0-14R| –| –| 1.949| 0.82| 4, 10, 25, 50
| 5/16″| TL1/0-56R| –| –| 1.949| 0.82| 4, 10, 25, 50
3/8″| TL1/0-38R| –| –| 1.949| 0.82| 4, 10, 25, 50
1/2″| TL1/0-12R| –| –| 1.98| 0.864| 4, 10, 50
2/0 AWG| 1/4″| TL2/0-14R| –| –| 2.18| 0.928| 4, 10, 50
| 5/16″| TL2/0-56R| –| –| 2.18| 0.928| 4, 10, 25, 50
3/8″| TL2/0-38R| –| –| 2.18| 0.928| 4, 10, 25, 50
1/2″| TL2/0-12R| –| –| 2.18| 0.928| 4, 10, 50
3/0 AWG| 1/4″| TL3/0-14R| –| –| 2.18| 1.047| 4, 10, 25
| 5/16″| TL3/0-56R| –| –| 2.18| 1.047| 4, 10, 25
3/8″| TL3/0-38R| –| –| 2.18| 1.047| 4, 10, 25
1/2″| TL3/0-12R| –| –| 2.18| 1.047| 4, 10, 25
4/0 AWG| 1/4″| TL4/0-14R| –| –| 2.242| 1.115| 4, 10, 25
| 5/16″| TL4/0-56R| –| –| 2.242| 1.115| 4, 10, 25
3/8″| TL4/0-38R| –| –| 2.242| 1.115| 4, 10, 25
1/2″| TL4/0-12R| –| –| 2.242| 1.115| 4, 10, 25

Lugs are commonly used with battery cables and create solid connections that are designed to weather some of the toughest environments out there. Built from tin plated copper, these lugs are designed for 100% conductivity ensuring that your electrical connections offer the longest protection possible.

Online Store
PacerGroup.net
Phone: 941.378.5774 Corporate Offices
1555 Apex Road Sarasota, FL 34240
Toll Free: 1.800.424.9549

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Pacer User Manuals