NOTIFICATION I.
Thanks for your purchase with AceVolt, please read the manual before use.
Warranty Card + Product Invoice = Valid Warranty
For safety during products transportation, the default power remaining is 30%.
After receiving the product, please use power supply facilities to recharge
the Campower immediately, such as wall sockets.
Please avoid Campower from following conditions:
NOTIFICATION II.
Please keep the Campower away from children and pets.
Please do not disassemble or modify the product, it could cause malfunction or fire, the caused issues are not included in our warranty.
Please ensure the cooling fan operates normally when you are using the Campower, leave a space of about 12 inches at both ventilation ports.
Please use Campower in a stable environment, it needs to be fixed during transportation to avoid vibration and drop.
When the Campower, the attached cables, or the connected devices are damaged or in poor condition, please stop using the product since it may cause malfunctions.
If the Campower drop into the water accidentally, please place it in a safe place until it is completely dry and the dried product should not be used again.
If the Campower catches fire accidentally, please orderly use water or water mist, sand, fire blanket, dry powder, and finally a carbon dioxide fire extinguisher, the product should not be used again.
If the Campower can not be used again, please dispose of the battery according to your local regulations and laws.
Please kindly check the products and accessories you received, when you encounter the following situations, please feel free to contact: [email protected]
DAMAGE
MISSING
WRONG
WhAT’S IN THE BOX
SPECIFICATIONS
SPECIFICATIONS I.
GENERAL
Battery Capacity 672Wh
Battery Lifecycle: 2500+ before reaching its 80% capacity
Battery Type: LiFePO4
Porduct Dimensions: 14.2 in 8.4 in 11.8 in/360mm213mm300mm
Product Weight: 22lbs/10KG
ENVIRONMENT
Charge Temperature: 32~104℉/0~40℃
Discharge Temperature: -4~104℉/-20~40℃
Storage Temperature: 32~113℉/0~45℃
Operating Environment Humidity: 10~90%
SPECIFICATIONS II.
OUTPUT
USB-A QC 3.0 2: 5 – 12V, 18W (Quick Charge)
Type-C PD 3.0 I : 5/9/12/15/20V,3A,20V,5A(E-Marker chip built-in)
AC Outputs 4 : 100-120V, 700W, Surge 1400W, 50Hz/60Hz
DC Outputs 5521 2 : 12V, 10A, 5.5mm x 2.Imm
Car Port Output: 12V, 10A
Wireless Charging: 5W/7.5W/10W/15W
INPUT
DC Input: 12-28 V, 200W
Solar Panel Input: 12-28V, 200W
Car Port Input: 12V/24V (start the car before charging)
PRODUCT DETAILS
DC &USB
Pressing this button will turn on the USB Output and 3 DC Output at the same
time.
The Campower will turn off automatically only in ECO Mode.
AC
Pressing this button will turn on the 2 AC Output.
The Campower will turn off automatically only in ECO Mode.
Display & Light
This button can turn on the LCD Display and LED Light with different pressing time.
Quick Press – LCD Display
Press the button for 1s then release – LED Light adjustment.
Wireless Charging
Pressing the DC button can turn on wireless charging.
Breathing Light
The breathing light will turn off automatically after 30s.
It works with LCD Display at the same time.
Ventilation Ports
The cooling fan will operate automatically when the temperature of the product
exceeds its normal working temperature.
Please ensure a space of around 12 inches at both ventilation ports, in case
of blocking the ventilation ports.
LCD DISPLAY
OVERLOAD
Power Overloaded
This icon indicates the Campower is overloaded, please kindly check the power
of the connected devices and ensure it is under the maximum power allowed, and
then press any button for 3s to reset
the Campower.
TEMP
Operating Temperature
When this icon lights up, the Campower temperature has beyond its range,
please remove big powerconnected devices and wait for it back to normal. Also,
the output power will decrease when it is beyond the operating temperature.
Please use and store the Campower according to the specifications.
SHORT
SHORT Short Circuit
Please check whether the connected devices are short circuits and remove them.
If not, please check whether the output power has exceeded the maximum power
allowed, it could result in a short circuit. Press any button for 3s to reset
the Campower.
ECO
ECO Mode
This icon shows your Campower is under the eco-mode, The Campower will
automatically turn off to save power when the AC output power is below 10W for
more than 4 hours.
How To Turn On/Off Eco Mode
- Enter The Setting Mode: Ensure the AC Button is turned off. Press both “AC” and “DC” buttons for 2s to enter the setting mode.
- Press the “DC” button to turn ON/OFF the eco mode.
- ExitThe Setting Mode: Press both “AC” and “DC” buttons for 2s to save and exit the setting mode.
How To Change Output Frequency
The unit will automatically recognize and adjust the output frequency, if the recognition fails, read the following steps to adjust it manually.
- Enter The Setting Mode: Ensure the AC Button is turned off. Press both “AC” and “DC” buttons for 2s to enter the setting mode.
- Change The Output Frequency: Press the “AC” button to switch the AC output frequency to either 50 or 60hz.
- Exit The Setting Mode: Press both “AC” and “DC” buttons for 2s to save and exit the setting mode.
FAQ
Q1: What are the advantages of the LiFePO4 battery?
A: Long lifespan, good safety performance, wide temperature range, no active
maintenance.
Q2: What devices can Campower 700 charge?
A: The AC outlets can only be used to charge the devices under 700 watts.
Q3: How do I know the charging time that my devices need?
A: The formula use to calculate: Working Time = 672Wh * 0.86 / Working Power
of the Device.
Q4: Can I charge my device while the Acevolt is being recharged?
A: Yes.
Q5: How to properly use and store the Campower 700?
A: Please pay attention to the environmental temperature and humidity based on
Environment Specification on Page 3, it is suggested to recharge the AceVolt
before its power is below 15%.
When you want to store the Campower for a long time, please ensure it has at least 30% power and it needs to recharge to 60% power every three months to maintain. Charge it to 60% before re-use.
For both use and storage, please keep it in a dry and ventilated environment, and keep it laid flat
For more FAQs, please visitwww.https://acevolt.com/
PROBLEM WITH INPUT
Please kindly check all the cables are correctly connected and not damaged.
Please kindly check the power supply facilities are normally working.
Please kindly check if the overload protection function has been activated,
the steps can be found in PRODUCT DETAILS II.
Please use the original cables to re-charge.
Please clean the dust and dirt on the surface and test under strong sunlight
if you are using solar panels.
Please check whether the cooling fan is blocked.
PROBLEM WITH OUTPUT
Please kindly check all the cables are correctly connected and not damaged.
Please press the button for 3s to reset the Campower
PROBLEM WITH LCD DISPLAY
Please press any button for 3s to reset the Campower
For more issues, please contact our customer support for help.
Customer Supports
For more information, please go to https://acevolt.com/
- Warranty
- FAQ
- Usage
Please prepare the following information for the quicker reply.
- Order Number
- Serial Number
- Problems
- Pictures / Videos
Customer Support
https://acevolt.com/
[email protected]
AceVoltTech
AceVoltTech
AceVoltTech
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:(1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC RF exposure statement:
The equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance between 20cm the radiator your body.
IC Caution:
Radio Standards Specification RSS-Gen, issue 5
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
This device may not cause interference.
This device must accept any interference, including interference that may
cause undesired operation of the device.
RF exposure statement:
The equipment complies with IC Radiation exposure limit set forth for
uncontrolled environment. This equipment should be installed and operated with
minimum distance 10cm between the radiator and your body.
ABOUT US
AceVolt was founded with more than 100 veteran campers & RV travelers from all over the United States who wanted to bring electricity to every chapter of their journey. Learn more about their stories.
Our company has had successful experience in manufacturing other electronics and energy storage devices since 2013. In order to power camping and other outdoor activities with clean energy and ensure a much longer product lifecycle and safety during family camping, we invited a team of 100+ camping enthusiasts to bring in a revolutionary solar-powered portable power station backed by state-of-the-art LiFePO4. These experienced campers participated in our product R&D and provided countless valuable suggestions. All their efforts led to the birth of the AceVolt brand.