HITACHI air Home 400 Room Air Conditioner Instruction Manual
- June 9, 2024
- Hitachi
Table of Contents
- SAFETY PRECAUTION
- PRECAUTIONS DURING INSTALLATION
- PRECAUTIONS DURING SHIFTING OR MAINTENANCE
- PRECAUTIONS DURING OPERATION
- NAMES AND FUNCTIONS OF EACH PART
- NAMES AND FUNCTIONS OF REMOTE CONTROLLER
- THE IDEAL WAYS OF OPERATION
- FOR USER’S INFORMATION
- ATTACHING THE AIR PURIFYING FILTERS
- WIRING ARRANGEMENT
- AFTER SALE SERVICE AND WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
OPERATION
MANUAL air Home 400
Room Air Conditioner
SPLIT TYPE DJ SERIES
MODELS:
RAK – DJ10PCASVX/ RAC – DJ10PCASVX
RAK – DJ13PCASVX/ RAC – DJ13PCASVX
SAFETY PRECAUTION
- Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
- Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
- The sign indicate the following meanings.
**** | Make sure to connect earth line. |
---|---|
Indicates the instructions that must be followed. | |
The sign in the figure indicates prohibition. | |
WARNING | This symbol shows that this equipment uses a fl ammable |
refrigerant.
If the refrigerant is leaked, together with an external ignition source, there
is a possibility of ignition.
---|---
CAUTION| This symbol shows that the Operation Instructions should be read
carefully.
CAUTION| This symbol shows that a service personnel should be handling
this equipment with reference to the Installation Manual.
CAUTION| This symbol shows that there is information included in the
Operation Manual and/or Installation Manual
- Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
WARNING| ● Do not reconstruct the unit.
Water leakage, fault, short circuit or fi re may occur if you reconstruct the
unit by yourself.
● Please ask your sales agent or qualifi ed technician for the installation of
your unit. Water leakage, short circuit or fire may occur if you install the
unit by yourself.
● Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or
the earth line of telephone. Improper installation of earth line may cause
electric shock. **
● Be sure to use the specifi ed piping set for R32. Otherwise, this may result
in broken copper pipes or faults.
● Do not use refrigerant other than the one indicated on the outdoor unit
(R32) when installing, moving or repairing.
Using other refrigerants may cause trouble or damage to the unit, and personal
injury.
---|---
CAUTION**| ● A circuit breaker should be installed depending on the
mounting site of the unit. Without a circuit breaker, the danger of electric
shock exists.
● Do not install near location where there is fl ammable gas. The outdoor unit
may catch fi re if fl ammable gas leaks around it.
● Please ensure smooth fl ow of water when installing the drain hose.
● Do not install the indoor unit in a machine shop or kitchen where vapor from
oil or its mist flows to the indoor unit. The oil will deposit on the heat
exchanger, thereby reducing the indoor unit performance and may deform and in
the worst case, break the plastic parts of the indoor unit.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
WARNING
● Should abnormal situation arises (like burning smell), please stop
operating the unit and turn off the circuit breaker. Contact your agent.
Fault, short circuit or fi re may occur if you continue to operate the unit
under abnormal situation.
● Please contact your agent for maintenance. Improper self maintenance may
cause electric shock and fi re.
● Please contact your agent if you need to remove and reinstall the unit.
Electric shock or fi re may occur if you remove and reinstall the unit yourself
improperly.
● If the supply cord is damaged, it must be replaced by the special cord
obtainable at authorized service/parts centers.
● If the air conditioner is not cool, one possible cause could be due to
refrigerant leakage, so consult your dealer.
The refrigerant gas used in the air conditioner is harmless. But if
refrigerant gas leaks into the room, harmful products are generated when in
contact with fi re from appliances such as a stove heater.
When there is refrigerant gas accumulation in the room, immediately stop the
air conditioner. Open the windows for ventilation and contact your agent.
PRECAUTIONS DURING OPERATION
WARNING
- Avoid an extended period of direct air fl ow for your health.
- Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn the breaker OFF.
- Do not use any conductor as fuse wire, this could cause fatal accident.
- During thunder storm, disconnect and turn off the circuit breaker.
- Spray cans and other combustibles should not be located within a meter of the air outlets of both indoor and outdoor units. As a spray can’s internal pressure can be increased by hot air, a rupture may result.
- The product shall be operated under the manufacturer specifi cation and not for any other intended use.
- Do not attempt to operate the unit with wet hands, this could cause fatal accident.
- When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen Insafe iciency.
- Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
- Please ensure that outdoor mounting frame is always stable, fi rm and without defect. If not, the outdoor unit may collapse and cause danger.
- Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
- Do not use any aerosol or hair sprays near the indoor unit. This chemical can adhere on heat exchanger fi n and blocked the evaporation water fl ow to drain pan. The water will drop on tangential fan and cause water splashing out from indoor unit.
- Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger.
- Turn off the circuit breaker if the unit is not to be operated for a long period.
- Do not climb on the outdoor unit or put objects on it.
- Do not put water container (like vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit.
- Do not place plants directly under the air fl ow as it is bad for the plants.
- When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the airdefl ector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
- If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
- This appliance is not intended for use by persons (including children) who are physically handicapped sensory or mental or lack of experience and knowledge. Unless supervised or instructed on the use of electrical appliances by persons responsible for their safety.
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT
OUTDOOR UNIT
MODEL NAME AND DIMENSIONS
MODEL | WIDTH (mm) | HEIGHT (mm) | DEPTH (mm) |
---|---|---|---|
RAK-DJ10PCASVX, RAK-DJ13PCASVX | 780 | 280 | 222 |
RAC-DJ10PCASVX, RAC-DJ13PCASVX | 658 | 530 | 275 |
INDOOR UNIT INDICATIONS
CAUTION
Turn off the circuit breaker if the unit is not be operated for a long period.
✩ If the power stays on and the unit is not operated, power is slightly
consumed in the control circuit. The power is saved by turning off the power
switch (or the circuit breaker when the power is supplied from the outdoor
unit).
NAMES AND FUNCTIONS OF REMOTE CONTROLLER
- This remote controller controls the operation and timer setting of the room air conditioner. The operating range of the remote controller from the indoor unit is 7m. If indoor lighting is used, the range may be shorter.
Precautions for Use
- Do not put the remote controller under direct sunlight and high temperature.
- Do not drop it on the fl oor, and protect it from water.
- If you press the FUNCTION button during operation, the air conditioner may stop for about 3 minutes for protection before you can start it again.
Capabilities
CAUTION
Do not use a stove or any other high temperature devices in proximity to the
indoor unit.
Cooling and Dehumidifying Capabilities
- If the heat present in a room exceeds the unit’s cooling capacity (for example, if there are many people in the room or other heating appliances are used), the preset room temperature may not be reached.
Refrigerant Information
● For the refrigerant charge information, please refer to the outdoor unit installation manual or specifi cation label.
THE IDEAL WAYS OF OPERATION
Suitable Room Temperature
Warning
Freezing temperature is bad for health and a waste of electric power.
Ventilation
Caution
Do not close the room for a long period of time. Occasionally open the door
and windows to allow the entrance of fresh air.
Effective Usage Of Timer
At night, please use the “OFF or ON timer or SLEEP timer operation mode”,
together with your wake up time in the morning. This will enable you to enjoy
a comfortable room temperature. Please use the timer effectively.
Install curtain or blinds
It is possible to reduce heat entering the room through windows.
Do Not Forget To Clean The Pre-Filter
Dusty air fi lter will reduce the air volume and the cooling efficiency. To
prevent from wasting electric energy, please clean the fi lter every 2 weeks.
Please Adjust Suitable Temperature For Baby And Children
Please pay attention to the room temperature and air fl ow direction when
operating the unit for baby, children and old folks who have difficulty in
movement.
FOR USER’S INFORMATION
The Air Conditioner And The Heat Source In The Room
Caution
If the amount of heat in the room is above the cooling capability of the air
conditioner (for example: more people entering the room, using heating
equipments and etc.), the preset room temperature cannot be achieved.
Not Operating For A Long Time
When the indoor unit is not to be used for a long period of time, please
switch off the power from the mains. If the power from mains remains “ON”, the
indoor unit still consumes about 3W in the operation control circuit even if
it is in “OFF” mode.
When Lightning Occurs
Warning
To protect the whole unit during lightning, please stop operating the unit and
remove the plug from the socket.
Interference From Electrical Products
Caution
To avoid noise interference, please place the indoor unit and its remote
controller at least 1m away from electrical products.
ATTACHING THE AIR PURIFYING FILTERS
-
Open the front panel
● Pull up the front panel by holding it at both sides with both hands. -
Remove the Pre-fi lter
● Push upward to release the claws and pull out the Pre-fi lter. -
Attaching the air purifying filters (Accessories) to the fi lter frame.
● Attach the air purifying filters to the C-case to the designated position.
● The cooling capacity is slightly weakened and the cooling speed becomes slower when the air purifying filters are used.
● The air purifying filters are not washable. It is recommended to use vacuum to clean. It can be used for 1 year. When you want to renew it, please ask your sales agent. CAUTION
Do not bend the air purifying fi lter as it may cause damage to the structure.
Please do not smell direct from source of fi lter. -
Attach the Pre-filters
● Attach the Pre-filters by ensuring that the surface written “FRONT” is facing front.
● After attaching the Pre-filters, push the front panel at three arrow portions as shown in figure and close it.
NOTE
- In case of removing the air purifying filters, please follow the above procedures.
- The cooling capacity is slightly weakened and the cooling speed becomes slower when the air purifying filters are used. So, set the fan speed to “HIGH” when using it in this condition.
- Air purifying filters are not washable. It is recommended to use vacuum to clean it. It can be use for 1 year time. Type number for this air purifying fi lter is
. Please use this number for ordering when you want to renew it. - Do not use detergent on the air purifying fi lter as some detergent may deteriorate the air purifying filter electrostatic performance.
MAINTENANCE
CAUTION
Before cleaning, stop operation and switch off the power supply.
PRE-FILTER
Clean the Pre-fi lter, as it removes dust inside the room. In case the Pre-fi
lter is full of dust, the air flow will decrease and the cooling capacity will
be reduced. Further, noise may occur. Be sure to clean the Pre-fi lter
following the procedure below.
PROCEDURE
-
Open the front panel and remove the Pre-fi lter
● Gently lift and remove the air purifying filters from the air purifying fi lter frame. -
Vacuum dust from the Pre-fi lter and air purifying fi lter using vacuum cleaner. If there is too much dust, rinse under running tap water and gently brush it with soft bristle brush. Allow filters to dry in shade. ● Re-insert the air purifying fi lter to the fi lter frame. Set the Pre-fi lter with “FRONT” mark facing front, and slot them into the original state.
● After attaching the Pre-filters, push the front panel at three arrow portions as shown in figure and close it.
CAUTION
- Do not wash with hot water at more than 40°C. The Pre-filters may shrink.
- When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to the sun. The Pre-filters may shrink.
- Do not use detergent on the Pre-fi lter as some detergent may deteriorate the Pre-fi lter electrostatic performance.
CLEANING OF FRONT PANEL
- Remove the front panel and wash with clean water. Wash it with a soft sponge. After using neutral detergent, wash thoroughly with clean water.
- When front panel is not removed, wipe it with a soft dry cloth. Wipe the remote controller thoroughly with a soft dry cloth.
- Wipe the water thoroughly.
If water remains at indicators or signal receiver of indoor unit, it causes trouble.
Method of removing the front panel.
Be sure to hold the front panel with both hands to detach and attach it.
- When the front panel is fully opened with both hands, push the right arm to the outside to release it, and while closing the front panel slightly, pull it out forward.
- Move the projections of the left and right arms into the Flanges in the unit and securely insert them into the holes.
CAUTION
- Never use hot water (above 40°C), benzine, gasoline, acid, thinner or a brush, because they will damage the plastic surface and the coating.
WIRING ARRANGEMENT
CAUTION
-
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock **** -
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
IMPORTANT
The wires in this mains lead are coloured in accordance with the following
code:
Green-and-yellow | : Earth |
---|---|
Blue | : Neutral |
Brown | : Live |
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured green-and-yellow must be connected to the terminal
in the plug which is marked with the letter E or by the earth symbol **or
coloured green or green-and-yellow.
The wire which is coloured blue must be connected to the terminal which is
marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is
marked with the letter L or coloured red.
NOTE
If the supply cord is damaged, it must be replaced by the special cord
obtainable at authorized service/parts centers.
CAUTION
Cleaning and maintenance must be carried out only by qualifi ed service
personnel. Before cleaning, stop operation and switch off the power supply.
FROSTWASH OPERATION**
Frost Wash Operation does not start| It does not wash when outside temperature
is less than about 21°C or more than 43°C.
When “Frost Wash” is done by operating a remote controller, it does not wash
when the room temperature is less than about 21°C or more than about 32°C.
---|---
When 60 minutes after the end of “Frost Wash”, “Frost Wash” is not operated
for product protection.
Noise occurred during Frost Wash operation| It is the sound that the internal
machine is inflated and contracted by the temperature change and the fin of
the heat exchanger is frozen and thawed
(Clean Function Lamp) blinks| Repeat for 1 second on and 1 second off for 10
seconds.
Because “Frost Wash” can not work when operating the “Frost Wash” with remote
controller.
● The air conditioner is operating
● Outside air temperature, room temperature and room humidity are not suitable
for “Frost Wash”
● It has not been over 60 minutes since the end of “Frost Wash”
Repeat for 4 seconds on and 1 second off for 15 seconds Because Frost Wash has
not been done for a long time.
→ Operate the remote controller to operate “Frost Wash”.
The following phenomena do not indicate unit failure.
Hissing or fizzy sounds| Refrigerant flow noise in the pipe or valve sound
generated when flow rate is adjusted.
---|---
Squeaking noise| Noise generated when the unit expands or contracts due to
temperature changes.
Rustling noise| Noise generated with the indoor unit fan’s rpm changing such
as operation start times.
Clicking noise| Noise of the motorized valve when the unit is switched on.
Perking noise| Noise of the ventilation fan sucking in air present in the
drain hose and blowing out dehumidifying water that had accumulated in the
condensed water collector. For details, consult your sales agent.
Changing operation noise| Operation noise changes due to power variations
according to room temperature changes.
Mist emission| Mist is generated as the air within the room is suddenly cooled
by conditioned air.
Odors| Caused as the smells and particles of smoke, food, cosmetics, etc.
present in room air become attached the unit and blown off into the room
again.
Does not reach the temperature setting| Actual room temperature may deviate
slightly from the remote controller’s temperature setting depending on the
number of people in the room, indoor or outdoor conditions.
Mold Guard Operation
Mold Guard operation does not start| If the air conditioner has operated in
cooling and drying mode, including auto mode, for less than 10 minutes, the
Mold Guard operation will not start even if the air conditioner is in off
mode.
If operation of the air conditioner is stop by OFF Timer or Good Sleep Timer,
the Mold Guard will not operate.
If ON Timer is set and on time is within about 2 hours, the Mold-Guard will
not operate.
---|---
During Mold Guard| **** (Clean Function Lamp) on the indoor unit lights up
during Mold Guard operation. If Mold Guard operation stop at middle point,
Frost Wash and Filter sign indicator will turn off.
Notes| The horizontal deflector remain open. Room temperature or humidity may
rise. Depending on situation, Mold Guard will operate with Fan Mode.
When there would be the window near indoor unit, the water might condense on
the window during Mold Guard. If necessary, to cancel Mold Guard.
When after Frost Wash operation, the water inside the indoor unit evaporates
and depending on the room conditions, may emitted as steam. But this is not a
malfunction. If necessary, to cancel Mold-Guard.
REGULAR INSPECTION
PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONNEL EITHER EVERY
HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT OR SERVICE SHOP.
1 | Is the earth line disconnected or broken? | |
---|---|---|
2 | Is the mounting frame seriously affected by rust and is the outdoor |
unit tilted or unstable?
3| | Is the plug of power line firmly plugged into the socket? (Please
ensure no loose contact between them).
If the unit still fails to operate normally after performing the above
inspections, turn the circuit breaker off and contact your sales agent
immediately.
Contact your sales agent immediately if the following phenomena should occur
- The circuit breaker switches off or the fuse blows frequently.
- The switch operation is not stable.
- Foreign matter or water accidentally enters the unit interior.
- The power cord gets excessively hot or its insulation is torn or stripped.
- TIMER lamp on the indoor unit display blinks. (As the nature of the failure can be identic ed by the blinking cycle, check the blinking cycle before turning off the circuit breaker.)
AFTER SALE SERVICE AND WARRANTY
WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS
CONDITION | CHECK THE FOLLOWING POINTS |
---|---|
● Do the batteries need replacement? |
● Is the polarity of the inserted batteries correct?
When it does not cool well| ● Is the fuse all right?
● Is the voltage extremely high or low?
● Is the circuit breaker “ON”?
● Is the setting of operation mode different from other indoor units?
● Is the pre-filter blocked with dust?
● Does sunlight fall directly on the outdoor unit?
● Is the air flow of the outdoor unit obstructed?
● Are the doors or windows opened, or is there any source of heat in the
room?
● Is the set temperature suitable?
● Are the air inlets or air outlets of indoor and outdoor units blocked?
● Is the fan speed “LOW” or “SILENT”?
Please contact your sales agent immediately if the air conditioner still fails
to operate normally after the above inspections. Inform your agent for the
model of your unit, serial number, date of installation. Please also inform
him regarding the fault.
Please note:
On switching on the equipment, particularly when the room light is dimmed, a
slight brightness fluctuation may occur. This is of no consequence.
The conditions of the local Power Supply Companies are to be observed.
Note
- Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21°C (70°F).
The recommended maximum and minimum operating temperatures of the hot and cold sides should be as below:
| | Minimum| Maximum
---|---|---|---
Indoor| Dry bulb °C| 21| 32
Wet bulb °C| 15| 23
Outdoor| Dry bulb °C| 21| 46
Wet bulb °C| 15| 26
Access the full version of the User Operation Manual by scanning the code.
https://docs.hitachiaircon.com/RAK-DJ-PCASVX-RAC-DJ-PCASVX
Cooling & Heating
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>