Fitiger SR-H Health Fitness Tracker Smart Ring User Guide

October 29, 2023
Fitiger

Fitiger SR-H Health Fitness Tracker Smart Ring User Guide
Fitiger SR-H Health Fitness Tracker Smart Ring

The statement

Please note that the So+ Ring Service is not intended to diagnose, treat or prevent any disease or medical condition. The information and data in the service are for reference and do not replace the professional or physi ian service. If you have any questions about the medical condition, it is better for you to  consult a doctor.

Product Specifications

  • outer surface material : zirconia ceramics
  • main material : stainless steel
  • storage capacity: It is recommended to connect app and synchronize data everyday. The data will store for up to 7 days and it depends on the type and
  • frequency of use. product weight : 5.5 gram
  • battery capacity : 18 mah lithium polymer batteries
  • battery time : 3-5 days, depending on the frequency of use
  • charging ways : use the charging cable provided, USB rated 5V
  • charging time : 45 minutes
  • light emitting sensor : LED of all visible colors, safe and friendly for users
  • connection method: Low-power Bluetooth 5.0
  • software program update : updates through software applications
  • software compatibility: the AppStore, Google Play
  • waterproof level : IPX8

APP download
Search for “SoPlus Ring” on Google Play or the App Store to download the APP Note: Please allow APP to obtain Bluetooth connection permission and location permission

Wear it correctly
Please put the detection sensor (see the inner ring) in close contact with the finger skin in order to obtain the accurate data.

Charging/Turn on/ Turn off Charging

Ring charging: Use the matching charging cable to connect the ring and charger. After the power is switched on, the ring indicator light will be on. Indicator status: When charging, the red light is on and when it is fully charged, the green light is on. Charging time: 45 minutes

Power consumption check: Check the power consumption icon in the upper right corner of the APP homepage

Low power warning: red light flashing, APP pop-up warning, indicating the need to charge

Instructions
Please keep the charging port dry without blocking to prevent short circuit. It is recommended to use a charger with a rated output voltage of 5V

Turn on/off
Turn on: After it is fully charged, disconnect the power supply and the ring will turn on automatically. Turn off: When the battery runs out, it will automatically shut down.

Bluetooth connection
After the power is disconnected, the ring will turn on automatically. The Bluetooth will turn on the broadcast. APP will search the device “So+” and select “Connection” . Note: Please enable the Bluetooth permission and location permission of the APP

Blood oxygen concentration monitoring
Automatic test: The ring automatically tests the blood oxygen concentration every 2 hours, saves the test data, and generates the historical record chart. Real-time test: Click ” test” button to test the real-time blood oxygen concentration value and save the latest real-time data. Note: Keep sitting still, and the red light in the inner ring keeps flashing whentheblood oxygen is monitored.

Resting heart rate monitoring
Automatic test: The ring automatically tests the resting heart rate every 10minutes, calculates the average heart rate per hour, saves the data, and generates the historical record char.Real-time test: Click the ” test ” button totest the real-time resting heart rate and save the latest real-time data. Note: Keep sitting still and the green light in the inner ring flashes continuously during heart rate monitoring.

Step statistics
Record the steps in real time, generate the record chart, and automatically synchronize the data after connecting the APP.

Temperature detection

The ring will automatically detect the temperature every hour, save the data and generate a record chart. After connecting the APP, the data will be automatically recorded.

Note: The temperature is the epidermal temperature of the finger skin, not thebody temperature.

Sleep monitoring
The ring records the complete sleep cycle in real time, scientifically analyze theduration of wakefulness, light sleep and deep sleep, and then generate a chart

Ring /APP upgrade
The APP detects the new version of the program automatically. For better user experience, please update the program and APP to the latest version.

Q &A

  1. The Bluetooth connection fails Please ensure that the Bluetooth and location permissions of the APP are enabled. When the ring has no power or low power, the Bluetooth connection cannot beamed. Please charge the ring.
  2. Data is inaccurate Please wear the ring correctly. The detection sensor in the inner ring is in close contact with the finger skin.
  3. The ring has been bound The ring has a unique ID. Ifyou need to bind a new APP account, please unbindthe ring from the APP account. If you forget the APP account, please contact the manufacturer

Exemption Rules

  1. Normal wear and tear, including scratches and dents.
  2. The consumable components, such as batteries.
  3. Damage caused by not complying with the instructions.
  4. Damage caused by force majeure, such as fire, flood and so on.
  5. Damage caused by unauthorized tampering or alteration of the product.

Maintenance Rules

  1. The surface of the ring is made of ceramic. Do not put hard objects together inured to avoid scratching the surface of the ring.

  2. Do not contact with strong acid and alkali chemicals to avoid corrosion.

  3. The outer ring is made of ceramic, which is very fragile so it should prevent
    crashing.

  4. Please clean with neutral solution and soft cloth.

  5. The ring contains batteries. Do not expose to high temperature for a long time.

FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

RF Exposure Information
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.

Read User Manual Online (PDF format)