Honeywell RTH8500 Programmable Thermostat Installation Guide
Read and save these instructions.
For help please visit honeywellhome.comFind
rebates: HoneywellHome.com/Rebates
Included in your box
Tools you will need
Tools you may need
Removing your old thermostat
-
Turn the power OFF.
To protect yourself and your equipment, Turn off the power at the breaker box or switch that controls your heating/cooling system. -
Check that your system is off. Change the temperature on your old thermostat. If you don’t hear the system turn on within 5 minutes, the power is off.
Note: If you have a digital thermostat that has a blank display, skip this step -
Remove the old thermostat’s faceplate. On most thermostats, you can take off the faceplate by grasping and gently pulling. Some thermostats may have screws, buttons, or clasps. Do not remove any wires from your thermostat at this time!
-
Make sure there are no 120/240V wires. Do you have thick black wires with wire nuts? Is your thermostat 120V or higher? If you answered yes to either of these questions, you have a line voltage system and the thermostat will not work. If you are unsure visit: honeywellhome.com/support
-
Take a picture of how your wiring looks right now. Be sure to include the letters next to the terminals where the wires are inserted. This will be a helpful reference when wiring your thermostat.
Tip: If the color of your wires has faded or if 2 terminals have the same wire color, use the wire labels provided in the package to label each wire. -
Record if you have wires in the following terminals. Do not include jumpers as a part of your count. The thermostat does not need jumpers.
-
Write down the color of the wires. Check mark the wires that are connected to terminals. Next to the check mark, write down the color of the wire. Do not include jumpers as a part of your count. Check all that apply (Not all will apply): The RTH8500 thermostat does not support S or U terminals. If there are wires in terminals that are not listed, you will need additional wiring support. Visit honeywellhome.com/support to find out if the thermostat will work for you.
-
Disconnect the wires and remove the old wall plate. Use a screwdriver to release wires from terminals. Then, use a wire label to identify each wire as it’s disconnected. The letter on the wire label should match the letter on the terminal.
Tip: To prevent wires from falling back into the wall, wrap the wires around a pencil.Installing your
RTH8500 thermostat -
Bundle and insert wires through the UWP. Pull open the UWP and insert the bundle of wires through the back of the UWP. Make sure at least 1/4-inch of each wire is exposed for easy insertion into the wire terminals.
-
Insert the wall anchors. It is recommended that you use the wall anchors included in the box to mount your thermostat. You can use the UWP to mark where you want to place the wall anchors.
-
Level the wall plate.
-
Mark the location of the wall anchors using a pencil.
-
Drill the holes.
-
nsert wall anchors.
-
Make sure anchors are flush with the wall.
Tip: If your box contains red anchors, drill 7/32” holes. -
If your box contains yellow anchors, drill 3/16” holes.
-
-
Set the R-switch position and insert the R-wire or wires. Set the R-switch up or down based on your wiring notes in Step 7. Insert wires into the inner holes of the terminals on the UWP. The tabs will stay down once the wire is inserted.
-
If you have 1 R-wire (R, Rh, or Rc)
If you have 2 R-wires (R or Rh, and Rc) -
Connect wires from Step 7. Depress the tabs to put the wires into the inner holes of their corresponding terminals on the UWP (one wire per terminal) until it is firmly in place. Gently tug on the wires to verify they are secure.
Tip: If you need to release the wires again, push down the terminal tabs on the sides of the UWP. -
Mount the UWP and close the door. Mount the UWP using the provided screws. Install all three screws into the wall anchors for a secure fit on your wall. Close the door after you’re finished
-
Confirm wiring matches the snapshot. Please confirm wiring matches the terminals from the photo you took in Step 5.
-
Install batteries. Insert three AA alkaline batteries in the back of the thermostat as shown.
NOTE: The RTH8500 thermostat works in battery mode or normal power mode if a C-wire is available. -
Attach your thermostat. Align the thermostat onto the UWP and firmly snap it into place.
-
Turn your power ON. Turn on the power at the breaker box or switch that controls the heating/ cooling system.
-
Return to the thermostat Return to the thermostat. Confirm the screen shows START SETUP. If your thermostat does not show START SETUP, please contact Honeywell Home support
-
Start setup. Touch START SETUP to begin
-
Navigate and edit setup options. Use the or to navigate through all the setup options. To see a list of all setup options, go to pages 9-10. To edit an option, touch Edit or touch text area. The value is now blinking. Use or to select the correct value. Touch Done or touch text area once the correct value is selected
-
Finish setup. Touch until you see FINISH SETUP. Touch Select or touch text area.
-
Set time and date. Set daylight saving time if you are in an area that follows daylight saving time. Set date, clock format, and time on the next screens.
-
Your thermostat is now setup. Refer to page 8 for more information about the basic operation
Key features
System Setup options
Number | Description | Options (factory default in bold) |
---|
120
|
Scheduling Options
| 0 = Non-Programmable
1 = 1-Week Programmable
2 = 5-2 Programmable
3 = 5-1-1 Programmable 4 = 7-Day Programmable
Note: You can change default MO-FR, SA-SU schedule here. To edit periods during days, temperature setpoints, or to turn Schedule On/Off, touch MENU and go to SCHEDULE.
125| Temperature Indication Scale| 0 = Fahrenheit
1 = Celsius
200
|
Heating System Type
| 1 = Conventional Forced Air Heat
2 = Heat Pump
3 = Radiant Heat (Boiler) 5 = None (Cool Only)
Note: This option selects the basic system type your thermostat will control.
| | Conventional Forced Air Heat:
1 = Standard Efficiency Gas Forced Air
2 = High Efficiency Gas Forced Air
3 = Oil Forced Air
4 = Electric Forced Air 5 = Hot Water Fan Coil
205| Heating Equipment Type| Heat Pump:
7 = Air to Air Heat Pump
8 = Geothermal
| | Radiant Heat:
9 = Hot Water Radiant Heat
12 = Steam
Note: This option selects the equipment type your thermostat will control. Note: This feature is NOT displayed if feature 200 is set to Cool Only.
218
|
Reversing Valve O/B
| 0 = O (O/B in Cool)
1 = B (O/B in Heat)
Note: This option is only displayed if the Heat Pump configured. Select whether reversing valve O/B should energize in cool or in heat.
220
|
Cool Stages / Compressor Stages 200=Conv / 200=HP
| 0, 1 , 2
Note: Select how many Cool or Compressor stages of your equipment the thermostat will control. Maximum of 2 Cool/Compressor Stages. Set value to 0 if you do not have Cool Stage/ Compressor Stage.
221
|
Heat Stages / Backup Heat Stages Heat Stages
| Heat Stages: 1 , 2
Backup Heat Stages: 0, 1
Note: Select how many Heat or Aux/E stages of your equipment the thermostat will control. Maximum of 2 Heat Stages for conventional systems. Maximum of 1 Aux/E stage for systems with more than 1 heating equipment type. Set value to 0 if you do not have Heat Stage/Backup Heat Stage.
230
|
Fan Control
| 1 = Equipment
2 = Thermostat
Note: This ISU is only displayed if ISU 205 is set to Electric Forced Air or Fan Coil.
300
|
System Changeover
| 0 = Manual
1 = Automatic
Note: Thermostat can automatically control both heating and cooling to maintain the desired indoor temperature. To be able to select “automatic” system mode on thermostat home screen, turn this feature ON. Turn OFF if you want to control heating or cooling manually.
303
|
Auto Differential
| 0 °F to 5 °F or 0.0 °C to 2.5 °C
Note: Differential is the minimum number of degrees rise or fall required during off cycle to switch from the last active mode (heat or cool) to the opposite mode when the thermostat is in auto-changeover. Differential is NOT deadband. The deadband temperature between when heating (or cooling) cycles on and cycles off to maintain setpoint is not adjustable. Honeywell Home uses an algorithm that fixes deadband at 0 °F.
Number | Description | Options (factory default in bold) |
---|
365
|
Cool 1 CPH (Cooling cycle rate stage 1)
| 1 – 6 CPH (3 CPH)
Note: This ISU is only displayed when Cool /Compressor Stages is set to 1 or more stages. Cycle rate limits the maximum number of times the system can cycle in a 1 hour period measured
at a 50% load. For example, when set to 3 CPH, at a 50% load, the most the system will cycle is 3 times per hour (10 minutes on, 10 minutes off). The system cycles less often when load conditions are less than or greater than a 50% load.
366| Cool 2 CPH (Cooling cycle rate stage 2)| 1 – 6 CPH (3 CPH)
Note: This ISU is only displayed when Cool /Compressor Stages is set to 2.
370
|
Heat 1 CPH (Heating cycle rate stage 1)
| 1 – 12 CPH
Note: This ISU is only displayed when Heat Stages is set to 1 stage or more stages. Cycle rate limits the maximum number of times the system can cycle in a 1 hour period measured at a 50% load. For example, when set to 3 CPH, at a 50% load, the most the system will cycle is 3 times per hour (10 minutes on, 10 minutes off). The system cycles less often when load conditions are less than or greater than a 50% load. The recommended (default) cycle rate settings are below for each heating equipment type:
Standard Efficiency Gas Forced Air = 5 CPH; High Efficiency Gas Forced Air = 3 CPH; Oil Forced Air = 5 CPH; Electric Forced Air = 9 CPH; Fan Coil = 3 CPH; Hot Water Radiant Heat
= 3 CPH; Steam = 1 CPH.
371
|
Heat 2 CPH (Heating cycle rate stage 2)
| 1 – 12 CPH
Note: This ISU is only displayed when Heat Stages is set to 2 stages. The recommended (default) cycle rate settings are below for each heating equipment type:
Standard Efficiency Gas Forced Air = 5 CPH; High Efficiency Gas Forced Air = 3 CPH; Oil Forced Air = 5 CPH; Electric Forced Air = 9 CPH; Fan Coil = 3 CPH; Hot Water Radiant Heat
= 3 CPH; Steam = 1 CPH.
375
|
Aux Heat CPH (Heating cycle rate Auxiliary Heat)
| 1 – 12 CPH
Note: This ISU is only displayed when ISU 200 = Heat Pump and ISU 221=1. It is only displayed when Auxiliary Heat is configured. The recommended cycle rate settings are below for each heating equipment type:
Standard Efficiency Gas Forced Air = 5 CPH; High Efficiency Gas Forced Air = 3 CPH; Oil Forced Air = 5 CPH; Electric Forced Air = 9 CPH.
425
|
Smart Response
| 0 = No
1 = Yes
Note: Smart Response is a comfort setting. Heat or Cooling equipment will turn on earlier, ensuring the indoor temperature will match the setpoint at the scheduled time. See page 16.
430
|
Minimum Cool Temperature Setpoint
| 50 °F to 99 °F (50 °F)
10.0 °C to 37.0 °C (10.0 °C)
Note: The cool temperature cannot be set below this level.
431
|
Maximum Heat Temperature Setpoint
| 40 °F to 90 °F (90 °F)
4.5 °C to 32.0 °C (32.0 °C)
Note: The heat temperature cannot be set above this level.
702| Air Filters| 0 – 1
Note: This ISU refers to the number of air filters in the system.
711
|
Air Filter 1 Replacement Reminder
| 0 = Off 10 = 45 Calendar Days
1 = 10 Run Time Days 11 = 60 Calendar Days
2 = 20 Run Time Days 12 = 75 Calendar Days
3 = 30 Run Time Days 13 = 3 Calendar Months
4 = 45 Run Time Days 14 = 4 Calendar Months
5 = 60 Run Time Days 15 = 5 Calendar Months
6 = 90 Run Time Days 16 = 6 Calendar Months
7 = 120 Run Time Days 17 = 9 Calendar Months
8 = 150 Run Time Days 18 = 12 Calendar Months
9 = 30 Calendar Days 19 = 15 Calendar Months
Note: Set a reminder for when to change your air filter. Choose either calendar or equipment run time-based reminder.
1401
|
Idle Brightness
| 0= Off, 0 – 5
Note: Adjust brightness of an inactive backlight (idle screen) from default 0 (backlight off) to 5 (maximum brightness). Common wire required for settings 1-5.
1410| Clock Format| 12 hour, 24 hour
1415
|
Daylight saving time
| 0 = Off
1 = On
Note: Set to Off in areas that do not follow Daylight Saving Time.
To access all system options in the table below, press and hold MENU for 5
seconds. Touch or to scroll through the list.
NOTE : Once you have cycled through all of the System Setup numbers, Done
is displayed. Press Select to save and exit
System operation settings
- Press the Mode button to cycle to the next available System mode.
- Cycle through the modes until the required System mode is displayed and leave it to activate
NOTE: Available System modes vary by model and system settings.
System modes
- Auto: The thermostat selects heating or cooling as needed.
- Heat: The thermostat controls only the heating system.
- Cool: The thermostat controls only the cooling system.
- Em Heat (only for heat pumps with auxiliary heat): The thermostat controls Auxiliary Heat. The compressor is not used.
- Off: The heating and cooling system is off. A fan will still operate if a fan is set to On or Circulate.
Fan operation settings
-
Press the Fan button to cycle to the next available Fan mode.
-
Cycle through the modes until the required Fan mode is displayed and leave it to activate.
NOTE: Available Fan modes vary with system settings.
Fan modes:- Auto: The fan runs only when the heating or cooling system is on.
- On: The fan is always on.
- Circ: The fan circulates randomly about 33% of the time.
Program Schedule
You can program four time periods each day, with different settings for
weekdays and weekends. We recommend the pre-set settings (shown in the table
below), since they can reduce your heating/cooling expenses. Wake – Set to the
time you wake up and the temperature you want during the morning, until you
leave for the day. Away – Set to the time you leave home and the temperature
you want while you are away (usually an energy-saving level). Home – Set to
the time you return home and the temperature you want during the evening,
until bedtime. Sleep – Set to the time you go to bed and the temperature you
want overnight (usually an energy-saving level).
NOTE: To temporarily or permanently override any of the above programs’
schedules, see page 13.
To adjust program schedules
- Touch the Menu on the thermostat home screen.
- Touch the or arrows until you see SCHEDULE, then touch Select.
- Touch the or arrows to select a period in a day or set of days, then touch Select on the period you want to edit. (You can only edit a period of days according to the schedule type selected. To change the schedule type, see setup # 120 on page 9.)
- Touch the time area, then touch or to adjust when the period starts. Touch Select to confirm.
- Touch the temperature area, then touch or to adjust your preferred temperature for the mode that’s currently active (either heating or cooling). Touch Select to confirm. Then touch or to adjust your preferred temperature for the inactive mode. Touch Select to confirm
- Edit the next period or use the until you see Done, then press Select to save changes and go to the home screen.
NOTE: To temporarily cancel a scheduled period (such as Saturday-Sunday Away, for example, because you’ll be home), go to the SCHEDULE option and touch the
or arrows to select a period. Touch Select on the period you want to cancel, then touch Cancel Period. To reactive the period you canceled, touch Cancel Period again to select the period start time and preferred temperature.
Schedule overrides
Hold Until (temporary hold): Overrides the current temperature setpoint for a
maximum of 12 hours. You might use this feature to hold a temperature until a
specific time.
Permanent hold: Overrides the current temperature set point permanently until
you manually change it or reactivate a schedule.
Program schedule override (temporary)
- Touch or on the thermostat home screen to set your desired temperature. Hold Until will appear together with the time the hold will end.
- To change when the hold will end, touch the time and wait until the time starts blinking. Then, touch or to set when you want the hold to end. Touch Hold Until once more to confirm changes and return to the home screen.
NOTE: After the hold period ends, the thermostat will automatically return to the program schedule. If you want to cancel the hold, touch Hold Until, and then touch Run Schedule
Program schedule override (permanent)
- Touch or on the thermostat home screen to reach your desired temperature. Hold Until will appear together with the time you want the hold to end.
- Touch Hold Until. Permanent Hold will appear on the screen. Touch Permanent Hold to hold this temperature until you manually change it.
NOTE : To end permanent hold and return to the program schedule, touch Permanent Hold and then touch Run Schedule
Wiring—conventional systems
Alternate wiring (conventional systems)
If labels do not match terminals, connect wires as shown below (see notes,
below).
NOTES:
- If you must connect both R and Rc wires, set the R Slider Tab to the down position (2 wires).
- If your old thermostat had both R and RH wires, set the R Slider Tab to the down position (2 wires). Then connect the R wire to the Rc terminal and the RH wire to the R terminal.
- If your old thermostat had only 1 C or C1 wire, connect it to the C terminal. If your old thermostat had 2 C or C1 wires, wrap each separately with electrical tape and do not connect them.
Wiring—heat pump
Connect wires: heat pump
- Match each labeled wire with the same letter on new thermostat.
- Insert the wires into the matching terminal.
NOTE : If you have difficulty inserting wires, you may have to press down the terminal push button next to the corresponding terminal.
Labels don’t match?
If labels do not match the letters on the thermostat, see “Alternate wiring (for heat pumps only)” below.
Alternate wiring (for heat pumps only)
NOTES:
- Keep R Slider Tab in the up position (1 wire).
- If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help.
- If your old thermostat had separate O and B wires, attach the B wire to the C terminal. If another wire is attached to the C terminal, stop now and contact a qualified contractor for help.
- If your old thermostat had Y1, W1 and W2 wires, stop now and contact a qualified contractor for help.
- This model doesn’t support the heat pump fault alert (L/A terminal). If this is desired, please contact a contractor for a replacement model.
NOTE: Do NOT use W for heat pump applications. Auxiliary heat must wire to AUX or E.
Smart Response® Technology
This feature allows the thermostat to “learn” how long the furnace and air
conditioner take to reach programmed temperature settings, so the temperature
is reached at the time you set. For example: Set the Wake time to 6 am, and
the temperature to 70°. The heat will come on before 6 am, so the temperature
is 70° by the time you wake at 6. The message “Recovery” is displayed when the
system is activated before a scheduled time period.
Battery replacement
Batteries are required to provide power when a common wire is not used.
Batteries are recommended to provide backup power if the common wire is used.
Install fresh batteries immediately when the low battery icon appears. The
icon appears about two months before the batteries are depleted. Even if the
low battery icon does not appear, you should replace batteries once a year, or
before leaving home for more than a month. If batteries are inserted within
two minutes, the time and day will not have to be reset. All other settings
are permanently stored in memory and do not require battery power.
NOTE : When replacing batteries, alkaline batteries are recommended.
Setting the time and date
Setting the time
- Touch Menu on the thermostat home screen.
- Touch the or arrows until you see CLOCK, then touch Select.
- Touch the +or – arrows until you see SET TIME, then touch Select.
- Press or to set the time (or press and hold the buttons to move more quickly). Touch Done when finished.
- Set clock format (12 hours or 24 hours) and daylight saving time in the same CLOCK sub-menu
Setting the date
- Touch Menu on the thermostat home screen.
- Touch the or arrows until you see DATE, then touch Select.
- Touch + or – o set the month, then touch Select to confirm.
- Continue to set day and year in the same way. Touch Select to save your changes.
Choosing Fahrenheit or Celsius
To select a temperature scale, follow the steps below.
- Touch the Menu on the thermostat home screen.
- Touch the or arrows until you see TEMP SCALE, then touch Select.
- Touch the +or -arrows to select FAHRENHEIT or CELSIUS then touch Done to save your changes.
- Touch Back to return to the thermostat home screen
Alerts and maintenance reminders
- Touch Menu on the thermostat home screen, then you’ll see the ALERTS submenu. (The ALERTS sub-menu will only be available when there’s an active alert.)
- Touch Select to view the alert. A 3-digit alert code will appear by the thermostat’s clock and a description of the alert will scroll on the screen.
- If the alert is non-critical, you’ll have the option to Snooze or Dismiss it. If you have multiple alerts, touch the or arrows to page through the list of active alerts and follow steps 1 and 2 above.
To see what each 3-digit alert code means and the action you should take, refer to the chart below.
Number | Alert/Reminder | Definition |
---|---|---|
170 | Internal Memory Error | The memory of the thermostat has encountered an |
error. Please replace the thermostat.
173| Thermostat Temperature Sensor Error| The sensor of the thermostat has
encountered an error. Please replace the thermostat.
181| Replace Air Filter (1)| Replace air filter (1). Reset the timer by
touching the “dismiss” button on thermostat screen after it is replaced.
405| Low Battery Alert| The batteries are getting low. Replace them within two
months.
407| Critical Low Battery| The batteries are almost depleted and should be
replaced as soon as possible.
Troubleshooting
If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.
1-year limited warranty
Resideo warrants this product, excluding the battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one (1) year from the date of first purchase by the original purchaser. If at any time during the warranty period, the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option). If the product is defective, return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or call Resideo Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage that occurred while the product was in the possession of a consumer. Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR
DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY THAT RESIDE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
CAUTION: MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube,
do not place the old control in the trash. Contact your local waste management
authority for instructions regarding recycling and proper disposal
NOTE : Not for use with 250, 500, or 750 MV systems
Electric Rating:
Terminal | Voltage (50/60Hz) | Running Current |
---|---|---|
W Heating | 20-30 Vac | 0.02-1.0 A |
W2 (Aux) Heating | 20-30 Vac | 0.02-1.0 A |
E Emergency Heat | 20-30 Vac | 0.02-0.5 A |
Y Compressor Stage 1 | 20-30 Vac | 0.02-1.0 A |
Y2 Compressor Stage 2 | 20-30 Vac | 0.02-1.0 A |
G Fan | 20-30 Vac | 0.02-0.5 A |
O/B Changeover | 20-30 Vac | 0.02-0.5 A |
L/A Input | 20-30 Vac | 0.02-0.5 A |
Customer Assistance
For assistance with this product, please visit http://honeywellhome.com
Or call Customer Care toll-free at
1-800-468-1502 Resideo Inc., 1985
Douglas Drive North
Golden Valley, MN 55422 This product is manufactured by Resideo Technologies,
Inc., Golden Valley, MN, 1-800-468-1502
©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under
license from Honeywell International Inc. All rights reserved. 33-00406—09
M.S. Rev. 09-19