CISCO Meraki CW9162I-MR Indoor WiFi 6E Access Point Installation Guide
- June 10, 2024
- Cisco
Table of Contents
CW9162I-MR Indoor WiFi 6E Access Point
Installation Guide
Meraki
CW9162I-MR
Hardware Installation Guide
Trademarks
Meraki CW9162I-MR, Meraki Cloud Controller, and Meraki Mesh are trademarks of
Cisco Systems, Inc. Other brand and product names are registered trademarks or
trademarks of their respective holders.
Statement of Conditions
In the interest of improving internal design, operational function, and/or
reliability, Cisco Systems reserves the right to make changes to the products
described in this document without notice. Cisco Systems does not assume any
liability that may occur due to the use or application of the product(s) or
circuit layout(s) described herein.
Warranty
Meraki, Inc. provides a lifetime warranty on this product. Warranty details
may be found at www.meraki.com/legal.
Scope of Document and Related Publications
The CW9162I-MR Hardware Installation Guide describes the installation procedure for the CW9162IMR indoor access point. Additional reference documents are available online at www.meraki.com/library/product.
CW9162I-MR Overview
The Meraki CW9162I-MR is an enterprise-class, dual-concurrent 4×4 MIMO
802.11ax indoor access point designed for high-density deployments in offices,
schools, hospitals and hotels. When connected to the Meraki Cloud Controller,
the CW9162I-MR enables the creation of ultra-high speed, reliable indoor
wireless networks quickly, easily and cost- effectively.
2.1 Package Contents
The CW9162I-MR package contains the following:
CW9162I-MR
access point
Mounting plate
Drop ceiling mounting
kit Wall screws
Security screws
Mounting Template
2.2 Understanding the CW9162I-MR
CW9162I-MR Operation Temperature: 32 ° F to 104 ° F (0 ° C to 40 ° C)
Your Meraki CW9162-MR has the following features:
Kensington lock hard point
Mount plate attachment slots (2x)
Cable access bay
Desk mount feet (4x) with M4*5mm pan-head screws
CW9162I-MR cable access bay
Factory Reset Button
Ethernet port Power supplied by PoE: 42.5-57Vdc,
AC Adapter plug (sold separately)
Power supplied by adapter: 12Vdc, 2.5A
Your CW9162I-MR mount plate has the following features:
Access point mounting posts (2x)
Various mounting holes
2.3 Security Features
The CW9162I-MR features multiple options for physically securing the access
point after installation:
- Security screw The accessory kit includes screws that can be used to secure the access point to the mount plate. Engaging the security screw prevents accidental dislodging and theft.
- Kensington lock The access point contains a hard point that allows it to be secured to any nearby permanent structure using a standard Kensington lock.
2.4 Ethernet Ports
The CW9162I-MR features an Ethernet RJ45 port that accepts 802.3af power
(labeled “PoE”). This port should be used for uplink to your WAN connection.
2.5 Power Source Options
The CW9162I-MR access point can be powered using either the Meraki AC Adapter
or 802.3af PoE Injector (both sold separately) or a third-party 802.3af PoE
switch.
2.6 Factory Reset Button
If the button is pressed and held for at least five seconds and then released,
the CW9162I-MR will reboot and be restored to its original factory settings by
deleting all configuration information stored on the unit.
Pre-Install Preparation
You should complete the following steps before going on-site to perform an
installation.
3.1 Configure Your Network in Dashboard
The following is a brief overview only of the steps required to add an
CW9162I-MR to your network. For detailed instructions about creating,
configuring and managing Meraki wireless networks, refer to the Meraki Cloud
Controller Manual
(meraki.com/library/product).
- Login to http://dashboard.meraki.com. If this is your first time, create a new account.
- Find the network to which you plan to add your APs or create a new network.
- Add your APs to your network. You will need your Meraki order number (found on your invoice if you ordered directly from Meraki) or the serial number of each AP, which looks like Qxxxxxxx-xxxx, and is found on the bottom of the unit. You will also need your Enterprise Cloud Controller license key, which you should have received via email from shipping@meraki.com.
- Go to the map / floor plan view and place each AP on the map by clicking and dragging it to the location where you plan to mount it.
3.2 Check and Upgrade Firmware
To ensure your CW9162I-MR performs optimally immediately following
installation, Meraki recommends that you facilitate a firmware upgrade prior
to mounting your CW9162I-MR.
- Attach your CW9162I-MR to power and a wired Internet connection. See p. 19 of this Hardware Installation Guide for details.
- The CW9162I-MR will turn on and the Power LED will glow solid orange. If the unit does not require a firmware upgrade, the Power LED will turn white within thirty seconds.
- If the unit requires an upgrade, the Power LED will begin blinking orange until the upgrade is complete, at which point the Power LED will turn solid white. You should allow about an hour for the firmware upgrade to complete, depending on the speed of your internet connection.
3.3 Check and Configure Firewall Settings
If a firewall is in place, it must allow outgoing connections on particular
ports to particular IP addresses. The most current list of outbound ports and
IP addresses can be found here:
http://tinyurl.com/y79une3
3.4 Assigning IP Addresses to CW9162I-MR
All gateway CW9162I-MR (CW9162I-MR with Ethernet connections to the LAN) must
be assigned routable IP addresses. These IP addresses can be dynamically
assigned via DHCP or statically assigned.
3.4.1 Dynamic Assignment
When using DHCP, the DHCP server should be configured to assign a static IP
address for each MAC address belonging to a Meraki AP.
Other features of the wireless network such as 802.1x authentication, may rely
on the property that the APs have static IP addresses.
3.4.2 Static Assignment
Static IPs are assigned using the local web server on each AP. The following
procedure describes how to set the static IP:
- Using a client machine (e.g. a laptop), connect to the AP either wirelessly (by associating to any SSID broadcast by the AP) or over a wired connection. If using a wired connection, connect the client machine to the CW9162I-MR either through a PoE switch or a Meraki PoE Injector. If using a PoE switch, plug an Ethernet cable into the CW9162IMR’s Ethernet jack, and the other end into a PoE switch. Then connect the client machine over Ethernet cable to the PoE switch. If using a Meraki PoE Injector, connect the CW9162I-MR to the “PoE” port of the Injector, and the client machine to the “LAN” port.
- Using a web browser on the client machine, access the AP’s built-in web server by browsing to http://my.meraki.com. Alternatively, browse to http://10.128.128.128.
- Click on the “Static IP Configuration” tab. Log in. The default username is “admin”. The default password is the AP’s serial number, with hyphens included
- Configure the static IP address, net mask, gateway IP address and DNS servers that this AP will use on its wired connection.
- If necessary, reconnect the AP to the LAN.
3.4.3 Static IP via DHCP Reservations
Instead of associating to each Meraki AP individually to configure static IP
addresses, an administrator can assign static IP addresses on the upstream
DHCP server. Through “DHCP reservations”, IP addresses are “reserved” for the
MAC addresses of the Meraki APs. Please consult the documentation for the DHCP
server to configure DHCP reservations.
3.5 Collect Tools
You will need the following tools to perform an installation:
3.6 Collect Additional Hardware for Installation 802.3at PoE power source (either PoE switch or Meraki 802.3at PoE Injector) Network cables with RJ45 connectors long enough for your particular mounting location
Installation Instructions
4.1 Choose Your Mounting Location
A good mounting location is important to getting the best performance out of
your CW9162IMR access point. Keep the following in mind:
- The device should have unobstructed line of sight to most coverage areas. For example, if installing in an office filled with workspaces divided by mid-height cubicle walls, installing on the ceiling or high on a wall would be ideal.
- Power over Ethernet supports a maximum cable length of 300 ft (100 m).
- If being used in a mesh deployment, the CW9162I-MR should have line of sight to at least two other Meraki devices. For more detailed instructions regarding access point location selection, reference the Meraki Network Design Guide (meraki.com/library/product).
4.2 Install the CW9162I-MR
For most mounting scenarios, the CW9162I-MR mount plate provides a quick,
simple, and flexible means of mounting your device. The installation should be
done in two steps. First, install the mount plate to your selected location.
Then, attach the CW9162I-MR to the mount plate.
!!! This equipment is only suitable for mounting at heights 2 m !!!
4.2.1 Attach the Mount Plate
The CW9162I-MR mount plate can be used to install your access point in a wide
range of scenarios: wall or solid ceiling, below a drop ceiling, on various
electrical junction boxes, or above a drop ceiling (in the plenum).
The mount plate contains a variety of hole patterns that are customized for
each installation scenario. The mounting template (included inbox with mount
plate) should be used to drill holes for wall mounts and also to identify the
correct hole patterns in the mount plate that should be used for each type of
mount.
The image below shows the hole patterns that should be used for each type of
mount:
4.2.1.1 Wall or Solid Ceiling Mount
Using Mount Plate
Using included screws, attach the mount plate to your mounting wall or
ceiling.
It is recommended that the CW9162I-MR be mounted to a wall or solid ceiling
using the mount plate for physical security reasons.
If mounting your CW9162I-MR to a wall, skip to “Power the CW9162I-MR” on P. 20
4.2.1.2 Electrical Junction Box Mount Using Mount Plate
The CW9162I-MR can be mounted to a 4″ square cable junction box, a 3.5 or 4″
round cable junction box, or various U.S. and European outlet boxes (mounting
screws are not included). Using appropriate mounting hardware for your
specific type of junction box, attach the mount
4.2.2 Power the CW9162I-MR
If mounting to an electrical junction box, feed the Ethernet cable through the
cable access hole in the Mount Plate. If mounting to a wall or ceiling, the
Ethernet cable will feed through the cable slot on bottom of the CW9162I-MR.
4.2.2.1 Powering the CW9162I-MR with the Meraki AC Adapter (sold
separately)
- Plug the power cord into the CW9162I-MR and the other end into a wall outlet.
- Plug an Ethernet cable that is connected to an active Ethernet connection into the Eth0 port on the CW9162I-MR.
4.2.2.2 Powering the CW9162I-MR with the Meraki 802.3at Power over Ethernet Injector (sold separately)
- Plug the power cord into the PoE Injector and the other end into wall power.
- Plug an Ethernet cable that is connected to an active Ethernet connection into the “IN” port on the injector.
- Route Ethernet cable from the “OUT” port on the injector to the Eth0 port in the cable bay of the CW9162I-MR.
4.2.2.3 Powering the CW9162I-MR with an 802.3at Power over Ethernet
Switch
Route Ethernet cable from a port on an active 802.3at PoE switch to the Eth0
port in the bay of the CW9162I-MR.
The CW9162I-MR is Gigabit Ethernet-capable. To maximize device performance, a
Gigabit-capable switch should be used.
4.2.3 Mount the CW9162I-MR
4.2.3.2 Assemble CW9162I-MR to the
Mount Plate
(This section applies to wall and/or solid ceiling, drop ceiling or electrical
junction box mount where you have already installed the mount plate.)
Insert the top latch on the mount plate into the top mount plate attachment
slots on the back of the device. Rotate the bottom of the unit into the bottom
mount plate attachment slot. The unit will click into place.
4.2.3.3 Desk or Shelf Mount
The CW9162I-MR can be placed on a desk or shelf resting on the non-scratch
rubber feet.
The mount plate is not necessary for a desk or shelf mounting.
4.3 Secure the CW9162I-MR
Depending on your mounting environment, you may want to secure the CW9162I-MR
to its mount location. Your CW9162I-MR can be secured in several ways. If the
CW9162I-MR has been installed using the mount plate, it can be secured via
security screw (Torx and Philips head security screws are included; choose
one), and/or Kensington lock. If the mount plate was not used, the CW9162I-MR
can still be secured using a Kensington lock.
4.3.1 Security Screw
Install the security screw in the lower mount plate tab.
4.3.2 Kensington Lock
Attach a Kensington lock cable to the access point at the hard point on the
side of the device. Attach the other end of the cable to a secure location,
such as a pipe or building fixture.
4.4 Verify Device Functionality and
Test Network Coverage
-
Check LEDs
The LED should be solid white. If it is flashing orange, the firmware is automatically upgrading and the LED should turn green when the upgrade is completed (normally in under thirty minutes). Note: Your CW9162I-MR must have an active route to the Internet to check and upgrade its firmware. -
Verify access point connectivity
Use any 802.11 client device to connect to the CW9162I-MR and verify proper connectivity using the client’s web browser. -
Check network coverage
Confirm that you have good signal strength throughout your coverage area. You can use the signal strength meter on a laptop, smart phone, or other wireless device.
Troubleshooting
Reference the Meraki knowledge base at http://meraki.com/support/knowledge_base for additional information and troubleshooting tips.
Regulatory
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) This de- vice may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to correct the interference by one of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications no expressly approved by Meraki could void the
user’s authority to operate this equipment. This Transmitter must not be co-
located or operation in conjunction with any other antenna or transmitter.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 41 cm between the radiator and your body. This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter.
IEEE 802.11b or 802.11g operation of this product in the USA is firmware-
limited to channels 1 through 11.
FCC regulations restrict the operation of this device to indoor use only.
The operation of this device is prohibited on oil platforms, cars, trains,
boats, and aircraft, except that operation of this device is permitted in
large aircraft while flying above 10,000 feet.
Operation of transmitters in the 5.925-7.125 GHz band is prohibited for
control of or Communications with unmanned aircraft systems. Professional
installation is required If the device is going to be operated in the 5.15 –
5.25 G H z frequency range, then it is restricted to indoor environment only.
This device meets all other requirements specified in Part 15E, Section 15.407
of the FCC Rules.
Industry Canada Statement
HVIN:CW9162I-MR V01 This device contains licence-exempt
transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s). Operation is subject to the
following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Industry Canada
Caution (i) the device for operation in the band 5150-5250 MHz is only for
indoor use to reduce the potential for harmful interference to co-channel
mobile satellite systems;
Industry Canada Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 24 cm between the radiator & your body.
The Country Code Selection feature is disabled for products marketed in the
US/Canada.
For product available in the USA/Canada market, only channel 1~11 can be
operated. Selection of other channels is not possible.
Operation shall be limited to indoor use only.
Operation on oil platforms, cars, trains, boats and aircraft shall be
prohibited except for on large aircraft flying above 10,000 ft.
EU/UK
(EU)
Radio | Frequency Bands | Maximum Total EIRP Power Level (dBm) |
---|---|---|
Wi-Fi | 2400-2483.5M Hz | 23 |
5150-5250 MHz | 23 | |
5250-5350 MHz | 23 | |
5470-5725 MHz | 30 | |
5945-6425 MHz | 23 | |
Bluetooth Low Energy (BLE) | 2400-2483.5MHz | 9.92 |
(UK)
Radio | Frequency Bands | Maximum Total EIRP Power Level (dBm) |
---|---|---|
Wi-Fi | 2400-2483.5MHz | 23 |
5150-5250 MHz | 23 | |
5250-5350 MHz | 23 | |
5470-5725 MHz | 30 | |
5725-5850 MHz | 23 | |
5925-6425 MHz | 23 | |
Bluetooth Low Energy (BLE) | 2400-2483.5MHz | 9.92 |
This equipment complies with EU & UK radiation exposure limits set forth for
an uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cm between the radiator & your body.
CE The device is restricted to indoor use only when operating in the 5150
to 5350 MHz, 5945 to 6425MHz frequency range.
| AT| BE| BG| HR| CY| CZ| DK
---|---|---|---|---|---|---|---
EE| Fl| FR| DE| EL| HU| IE
IT| LV| LT| LU| MT| NL| PL
PT| RO| SK| SI| ES| SE| UK
UKThe device is restricted to indoor use only when operating in the 5150 to 5350 MHz, 5925 to 6425MHz frequency range.
| UK
---|---
Hereby, Cisco Systems Inc. declares that the radio equipment type CW9162I series is in compliance with Directive 2014/53/EU and Radio Equipment Regulations 2017. The full text of the EU/UK declaration of conformity is available at the following internet address: https://meraki.cisco.com/compliance/?sortby=most-recent
Safety caution:
Ensure to connect the power cord of the power adapter to a socket outlet with
an earthing connection.
This equipment is suitable for use in environment air spaces(plenums)in
accordance with Section 300.22(C) of the National Electrical Code, and
Sections2-128,12-010(3) and 12-100of the Canadian Electrical Code, Part 1,
CSAC22.2. External power supply, power adapter and/or power injector, if
provided, are not suitable for installation in air spaces. Statement 440
Ensure that the AP is powered using a UL-compliant PoE power source. You must
connect the unit only to PoE network without routing to the outside plant.
Copyright
© 2020 Cisco Systems, Inc.
All rights reserved. Trademarks
www.ciscosystems.com
Cisco Systems, Inc. 170
West Tasman Drive San
Jose, CA 95134 USA 25
References
- Wi-Fi 6E | Network Security | Switches | Routers | Cisco Meraki
- Meraki Collateral | Cisco Meraki
- Document
- Cisco Meraki
- Document
- Meraki Collateral | Cisco Meraki