WARNING:
Please read the instructions carefully before commissioning. Failure to comply
with the safety instructions and instructions may result in electric shock,
fire and/or serious injury. Keep all safety instructions and instructions for
future reference.
Heads up! Do not open the unit until the mains plug is removed from the
mains socket.
Danger to life through electric shock! Have repairs carried out only by an
authorised specialist workshop.
Only install the device in rooms with a surface area of more than 20m². Do not install the appliance in a place where flammable gas can escape.
The environmentally friendly R290 is used as refrigerant. R290 has no harmful effect on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Due to its efficient energy properties, R290 is an excellent coolant for this application. Due to the high flammability of the coolant, special precautions must be taken.
Symbols
Danger from flammable gas
This symbol draws your attention to dangers to health and life caused by
extremely flammable gas.
Observe operating instructions
This symbol draws your attention to the fact that the operating instructions
must be followed before installing and operating the device.
Observe operating instructions and operating notes
This symbol draws your attention to the fact that the operating instructions
and the operating notes contained therein must be taken into account and
observed.
Rep ir instructions, observe technical manual
Activities on the refrigeration circuit, such as disposal, repairs and
maintenance activities, may only be carried out by persons with a relevant
certificate of competence and only in accordance with the manufacturer’s
specifications. Repair instructions as well as maintenance and disposal
information can be obtained from the manufacturer on request.
Danger
There is danger for the device or objects in the vicinity of the device.
Electrical hazard
shock hazard
Safety Instructions
Do not use any agents other than those recommended by the manufacturer to
speed up the defrosting process or to clean the dehumidifier.
The appliance must be stored in
a room without constantly operating ignition sources (e.g. naked flames, a gas
appliance switched on or an electric heater switched on).
Do not puncture or burn the
device, even after use.
Use the on/off switch to switch the unit on and off
Never use the plug to switch the appliance on and off
The device may only be installed, operated and stored in a room with a floor
space of more than 20m².
Maintenance may only be carried out in accordance with the manufacturer’s
instructions.
The unit must be stored in a well-ventilated area where the room size
corresponds to the room size specified for operation.
All work processes that affect
safety-relevant aspects (e.g. repairs) may only be carried out by qualified
personnel.Do not immerse the unit in
water or other liquids. If the power cord is damaged, it must be replaced by
the manufacturer, its service partner or similarly qualified persons to
avoid any risk of danger.
Please contact a professional to have the product repaired. Improper repairs can lead to injuries to the user. Disconnect the appliance from the power supply before moving, cleaning or servicing it and also when it is not in use or in case of malfunction. Never pull the power cord. Observe the national installation regulations and only connect the device to a correctly installed grounded contact socket with a mains voltage/frequency as specified on the type plate. Do not place or place any objects on the dehumidifier. Do not climb or sit on the device. Do not unplug the device by pulling on the power cord. Always grasp the mains plug for this purpose. Do not tilt or fall the device. As the water that escapes through this can damage the device. This appliance may be used by children aged 8 years and older and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, provided they have been supervised and/or instructed in the safe use of the appliance and understand the hazards involved. Do not allow children to play with the device. Cleaning and maintenance must not be carried out by children without supervision. Do not place the unit directly against a wall or under a wall cabinet or similar. The unit requires a clearance of at least 50 cm at the top and on all sides.
The device is only to be used in the temperature range between 5°C and 35°C.
Do not use the device in a wet area. The device is not protected against
splash water.
Position the device on a flat, stable, non-slip, hard and dry surface. This is
to prevent increased noise, vibration, water leakage or electric shock.
Never insert your fingers or other objects into the device. This can lead to damage to the device. Do not touch the air inlet or the aluminium fins of the unit. Unplug the device after switching it off or if you do not intend to use it for a long period of time. The working area of the device must be at least 20m².
It must be ensured that there are no flammable materials in the working area of the device. Do not clean the dehumidifier with water or chemicals.
Prevent water from getting on/on the appliance. Do not spray the unit withflammable liquids or cleaning agents. Do not touch the ventilation slots. Keep the air inlet and outlet free of obstacles. Keep all necessary ventilation openings free of obstacles. Do not use the device if the power cord is damaged. Do not use the device in hermetically sealed rooms.
eep the water tank free of foreign objects. Install the unit away from heaters or heat generating devices. The device must not be used in environments with high dust or chlorine content. Only use the device if your power outlet is equipped with an RCD (FI) circuit breaker.
Do not operate/touch the device with wet hands. Do not attempt to carry out repairs or other adjustments to the device yourself. Do not let children play with the packaging, such as plastic foil. Make sure that the dehumidifier is positioned far away from fire, flammable, corrosive and explosive materials. Insert the power plug firmly and securely into the power outlet. Do not operate the dehumidifier via a multiple socket, plug adapter orextension cord. Do not operate the appliance if it has been dropped or damaged, or if it shows signs of malfunction. Do not operate the unit in the immediate vicinity of walls, curtains or other objects that may block the air inlet and outlet. If the unit has been tilted more than 45°, leave it upright for at least 24 hours before use. Do not operate or store the device in direct sunlight or rain.
Never place the power cord or the device on hot surfaces or near heat sources.
Route the power cord so that it does not come into contact with hot or sharp
objects.
Do not bend the power cord or wrap it around the appliance as this may cause
the cord to break. Please note that in addition to switching off the device,
you must also pull the mains plug out of the protective contact socket to
disconnect the device completely from the mains. Do not use naked flames,
cigarettes or other possible ignition sources inside or near the equipment.
Transport, storage and disposal
When transporting equipment and parts that contain flammable refrigerants, the transport regulations must be observed. The disposal of appliances containing flammable refrigerants must be carried out in accordance with national regulations. The maximum number of units that may be storedtogether is determined by local regulations The device must be stored insuch a way that no mechanical damage can occur. Empty the water tank before moving the appliance to avoid water leakage.
Notes on the refrigerant R290
The unit is only designed for use with R-290(propane) gas as refrigerant. The
refrigerant circuit is sealed. Maintenance work in this regard may only be
carried out by a qualified technician. The maintenance manual must be
requested from themanufacturer by the technician. Do not release the
refrigerant into the atmosphere.
R290 (propane) is extremely flammable and heavier than air. It first collects
in low areas, but can be circulated by fans. If propane gas is present, or
suspected to be present, do not allow untrained personsto search for the
cause. The propane gas used in this unit is odourless. Therefore, gas may have
escaped even without any perceptible smell.
The components used are designed for propane gas and are therefore non- ignitable and non-sparking. Components may only be replaced by identical spare parts approved by the manufacturer. Note that the refrigerant is odourless. Compliance with national gas regulations must be observed.
Failure to comply with the safety instructions can lead to explosion, death, injury and material damage.
Attention| Any person carrying out work on the refrigerant circuit
shall hold a current valid certificate of competence issued by an assessment
body accredited by the industrywhich demonstrates their competence to safely
handle refrigerant in accordance with a procedure recognised by the industry.
---|---
Attention| Maintenance may only be carried out in accordance with the
manufacturer’s instructions. During maintenance and repairs requiring the
assistance of other specialists, the person trained in handling flammable
gases must constantly monitor the work
If you do not understand something or need help, please contact the manufacturer. You will find the contact details at the end of this manual.
Appropriate use
The dehumidifier is only intended for dehumidifying privately used rooms (e.g. living rooms, bedrooms, storage rooms or cellars). The user must comply with the specified operating parameters of this manual. The machine may only be used for its intended purpose. Any other use beyond this is not intended. The user/operator and not the manufacturer is liable for any damage or injury of any kind resulting from this.
Operating instructions
The device is designed for a temperature range between 5 and 35°C. Below 5°C
the air
humidity tends to be very low, so you do not need to use a dehumidifier. Above
35°C, the overheating protection may automatically switch off the unit. The
device is not approved for operation outside the temperature range. The
dehumidifier warms the air so that it can dehumidify optimally. Therefore the
room temperature can rise by 1-2 degrees. This is quite normal and increases
the efficiency of the device. When the water tank is full, the appliance
switches off automatically.
Leave the appliance in its final, upright position for at least 24 hours before starting it up for the first time. Always operate the appliance in an upright position and do not tilt it during operation.
Technical data
- Product name: Comedes BTR 50
- Voltage: AC220~240V/50 Hz
- Nominal power: 650W (30°C 80% humidity)
- Power consumption: 3.1 A (30°C 80% humidity)
- Dehumidification capacity: 51 l/ day (30°C 80% humidity)
- Weight: 36 kg
- Permissible operating temperature: 5-35°C
- Coolant / quantity: R290/230g
- Water tank size: 5,5 l
- Noise level: ≤ 52 dB(A)
- Dimensions: 430x515x825 mm
- Max. suction/pressure side
- Operating pressure: 0.7MPa/3.2MPa
- Max. permissible pressure on the
- High/low pressure side: 3.2MPa
- Max. permissible pressure heat exchanger: 3,2MPa
Device description
_Figure 1:
Figure 2:
_
Control panel
Figure 3: Display
Display:
The display shows the prevailing room air humidity. While setting the timer
and target humidity, the selected values are displayed. When the setting is
completed, the current room air humidity is displayed again.
Assembly
Accessories included in delivery
- Air dehumidifier
- Transport handle
- Stainless steel screw
- Spacer washer
- Wheel
- Spacer washer
- Screw nut 8 Pedestal
For the assembly is required:
- Wrench M6
- Screwdriver
- Soft underlay (blanket, sleeping mat, towel or similar)
Assembly steps for the BTR 50:
Attention Please note that the device is heavy. To avoid injuries or damage to the device and objects in the vicinity, the installation should be carried out by 2 persons.
A) Preparation
a. Remove the dehumidifier from the packaging and check it for damage
b. Check the accessories (mounting set) for completeness.
c. Prepare the tools required for the assembly
B) Mounting (See Figure 4)
a. Carefully place the device on its front side. Lay a soft surface
(blanket, mattress, towel, etc.) underneath to avoid damage such as scratches.
b. Assemble the transport handle using the 4 stainless steel screws, as
shown in Figure 4.
c. Mount the two wheels as shown in Figure 4.
d. Now carefully place the device on its back. Lay a soft surface
(blanket, mattress, towel, etc.) underneath to avoid damage such as scratches.
e. Mount the stand as shown in Figure 4.
f. Return the dehumidifier to an upright position.
Leave the appliance in its final, upright position for at least 24 hours before starting it up for the first time. Always operate the appliance in an upright position and do not tilt it during operation.
Installation Instructions
Operate the device only in rooms with at least 20m². floor space
-
Remove all adhesive tapes that were used for transport securing.
-
Check that the device is standing securely on firm, level and dry ground.
-
Never install the unit where it may be exposed to the following conditions:
- Never install the unit where it may be exposed to the following conditions:
- Heat sources, such as radiators, heat registers, stoves or other products that generate heat
- In an area where oil or water can be splashed.
- Direct solar radiation
- Mechanical vibrations or shocks
- Excessive dust exposure
- Lack of ventilation, e.g. in a cupboard or bookshelf
- Uneven surface
-
Make sure that the power outlet is equipped with an RCD (ground fault circuit interrupter).
If you are not sure whether this is the case, you can ask your electrician or use a personal protection plug (available at a hardware store). -
To save power and avoid potential hazards, disconnect the unit when not in use.
-
Keep at least 50cm distance around the device to walls and objects. Make sure that the air outlet is free and that there are no curtains or textiles above it.
Before commissioning
After unpacking the device, check it for completeness and possible transport damage to avoid any hazards. In case of doubt, do not use it, but contact our customer service. The service address can be found at the end of this manual.
Your device is in a package to protect it from transport damage.
- Carefully remove the device from its sales packaging.
- Remove all packing parts.
- Clean the unit and all accessories from packaging dust residue, as described in the chapter “Maintenance”.
Commissioning
Before connecting the power plug, check the device and especially the cable
for damage. The device may only be operated with a faultless mains cable.
Connect the power cord and switch on the unit with the on/off switch.
WARNING: Always allow the appliance to run for at least 35 minutes before
switching it off and never switch it off and on continuously. There would be a
risk of compressor damage. Leave the Comedes BTR 50 to stand for at least 3
minutes after switching off, without moving the appliance, so that the water
in the drip tray can drain completely. The higher the humidity in a room and
the higher the temperature in it, the better the Comedes BTR 50 can dehumidify
the air. Therefore, the compressor will generate heat and thus heat the room
air. This is quite normal and need not worry you.
Note: Before using the device for the first time, we recommend that you operate it for 5-10 minutes with the window open to remove any production- related residues. Any smell that may occur is normal and disappears after a short time. This is not a malfunction of the device. Ensure adequate ventilation.
**On / Off switch:**
Press the On / Off switch to switch on the appliance; the dehumidifier starts in continuous operation and the current indoor humidity is shown on the display. Press the On / Off switch again to turn the unit off. The compressor switches off immediately, the fan switches off with a 1 minute delay. In standby, “- -” is shown on the display.
Automatic operation
The device is equipped with a modern hygrostat (humidity controller) and
switches off
automatically when the desired humidity is reached. The compressor switches
off first and then the fan 60 seconds later. If the humidity in the room rises
again, the Comedes BTR 50 switches on again automatically. In automatic mode,
values from 20% to 90% can be set. The basic setting in automatic mode is a
target humidity of 50%. If the “CNT” LED does not light up, the unit is in
automatic mode and the desired target humidity can be set in 5% steps by
repeatedly pressing the plus or minus key. The switching hysteresis is 3%RH.
Continuous operation
To operate the unit in continuous operation (CNT), press the “CNT” key. If the device works in continuous operation, the corresponding “CNT” LED is lit. To switch from continuous operation back to automatic mode, press the “CNT” key. The “CNT” LED goes out. During operation, the current humidity is shown on the display. In continuous operation, the appliance dehumidifies until the water tank is full, or the appliance is switched off manually or a set running time has elapsed.
Timer
Press the timer button to start the timer function. You can set a time of 1-24
hours by
repeatedly pressing the Plus or Minus key. If the timer is activated, this is
indicated by the corresponding LED. If you activate the timer during
operation, the unit switches off after the set time. If you activate the timer
while the unit is in standby mode, the unit will start automatically after the
set time has elapsed. If the timer is active, the “Timer” LED lights up. To
turn off the timer, press the timer button again.
Temperature display
Press and hold the Timer button for at least 3 seconds and the current room
temperature is shown on the display. After approx. 10 seconds, the current
room humidity is displayed again.
Empty water tank:
When the water tank is full, the Comedes BTR 50 will automatically shut down and the Tank Full indicator ( Fig. 3) will light up. This is also signalled acoustically (15x beeps). To stop the alarm, press the power button and turn off the unit. You must empty the water tank to be able to put the BTR 50 back into operation. To do this, always switch off the device first and pull the mains plug.
The water tank is located behind a cover on the front of the unit. Open this
cover to access the tank. Now grasp the water tank by the handle on its upper
side and pull it horizontally out of the appliance.
Now empty the water tank completely into a sink or similar and put it back into the appliance. Make sure that the tank is correctly inserted to ensure proper operation of the unit.
Make sure that the plug of the water tank closes the connection for the hose
securely and firmly.
Attention:
-
To ensure correct and safe operation of the unit, the float must not be removed from the water tank
-
If the water tank is dirty, it should be cleaned. Use cold or warm water without
additives. Additives or cleaning utensils such as detergent, steel wool, benzene or other chemical cleaners are not suitable as these can damage the tank and cause leakage. -
To protect the compressor, it has a 3 minute switch-on delay.
Hose drainage
The Comedes BTR 50 can also be operated with a drainage hose (Ø11.0mm). To do
this, remove the water tank and attach a drainage hose. Proceed as follows:
- Remove the water tank and empty it completely.
- Pull the plug from the hose connection of the water tank and insert it back into the appliance.
- Insert a suitable drainage hose from the outside through the opening provided in the housing.
- Now attach the hose to the hose connection of the water tank. If necessary, pull the water tank slightly out of the device. Then close the tank cover.
- Now lay the drainage hose to a suitable drain and make sure that the hose remains in the intended position there.
- To use the unit in tank operation again, pull off the drainage hose and close the connection for the hose on the water tank securely and firmly with the plug.
Attention:
- Make sure that the hose does not run higher than the hose connection on the appliance at any point, so that the water can run off without disturbance.
- Make sure that the drainage hose does not hang in the water.
- Make sure that the drainage hose is not kinked or blocked. Check this regularly.
After each use and before attaching or removing accessories, the appliance must be switched off and disconnected from the mains by removing the mains plug from the socket outlet with earthing contact after switching off. Allow the appliance to cool to room temperature before cleaning and/or storing.
Automatic defrosting system
To ensure safe operation of the unit, the dehumidifier switches off automatically at ambien temperatures <5°C and >38°C. The dehumidifier is equipped with a temperature-dependent defrost function. When the temperature sensor detects a temperature of ≤-1°C (for at least 10 seconds) on the evaporator, the appliance starts defrosting. The compressor switches off and the fan continues to run. During defrosting the corresponding (“DEFROST”) indicator on the control panel is lit. The defrosting process is active until the temperature measured at the evaporator exceeds 5°C or a defrosting cycle of 15 minutes has been carried out.
Recommendations for drying with the Comedes BTR 50
In order to achieve the best possible dehumidification result with the BTR 50,
the
energy use, we provide the following information: Since this manual can only
give limited help, we recommend that you find more information at:
www.comedes.com.
Basics for dehumidification with the Comedes BTR 50
The dehumidifier works similar to a refrigerator with a refrigerating
machine. This creates a cold surface (at the evaporator) where water
condenses. Depending on air humidity and ambient temperature, the water
condenses at the dew point temperature. For the dehumidifier to dehumidify,
the cold surface must be below the dew point temperature. As the water would
freeze at negative dew point temperatures, the dehumidifier can only work with
positive dew point temperatures. To ensure this, the dehumidifier is equipped
with a modern, temperaturecontrolled automatic defrosting system that keeps
the evaporator temperature between 0 and 5°C. To be able to dehumidify
sensibly, the dew point temperature should be above 5°C. If the dew point
temperature is below this, dehumidification is either not possible at all or
only very inefficiently. With the following table you can determine the dew
point temperature in your case. If the dew point temperatures are too low,
heating is recommended.
Attention:
Only heat the room with water-bearing heating units such as underfloor heating
and permanently installed radiators. If this is not possible, the room can be
preheated with another electric heater. However, the dehumidifier must not be
located in this room. The safety and operating instructions in this manual
must be followed under all circumstances.
Drying in case of problems with condensation
Condensation moisture usually occurs in cellars when moist air enters the
cellar in summer and condenses on the cold cellar walls. We recommend to
dehumidify the cellar room by room in continuous operation at first. Let the
appliance run continuously at first until you notice that the amount of water
you drain from the tank every day becomes less. Now place the device in the
next room. Once you have dried all rooms, we recommend selecting a central
installation location and operating the unit in automatic mode. This type of
dehumidification is more energy-efficient than if you dehumidify immediately
in automatic mode, as the appliance then switches off and on very frequently.
Drying in case of construction defects or water damage
In the case of construction defects and water damage, the cause should first
be eliminated. The rooms can then be dried with condensation dryers such as
the BTR 50. The dehumidifier is operated in continuous operation. The ambient
temperature should be at least 20°C(no more than 27°C).
Caution: Only heat the room with water-bearing heating units such as
underfloor heating and permanently installed radiators. If this is not
possible, the room can be preheated with another electric heater. However, the
dehumidifier must not be located in this room. The safety and operating
instructions in this manual must be followed under all circumstances. Please
note that, depending on the construction defect, drying of the insulation
layer may also be necessary can be. This must be carried out by a specialist
company.
Recommended air humidity for rooms
Basically this depends on the ambient temperature. The higher the temperature
of the room, the lower the relative humidity should be set, otherwise mould
growth in the room is favoured. The pleasant air humidity ranges from 35% to
65% relative humidity, depending on the ambient temperature. The following
diagram gives an indication of which humidity is optimal at which ambient
temperatures.
The diagram assumes that temperatures >=20°C are living rooms and temperatures
<=20°C are basement rooms.
Maintenance
Always switch off and unplug the appliance before starting cleaning,
maintenance or repair work.
A maintenance log must be kept for the operation of the device as follows
Maintenance log for Comedes BTR 50:
Serial number: ————————
Maintenance and service interval| 1| 2| 3| 4| 5|
6| 7| 8| 9| 10| 11| 12| 13| 14|
15
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
Check air inlet and outlet and removeimpurities.| | | | | | | | | | | | | | |
External cleaning| | | | | | | | | | | | | | |
Visual inspection of the water outlet(hose connection) for contamination| | |
| | | | | | | | | | | |
Check air filter for dirt and foreign bodies, clean or replace if neces-sary|
| | | | | | | | | | | | | |
Check device for damage (powercable, housing, tank, fan wheel)| | | | | | | |
| | | | | | |
Check fastening screws| | | | | | | | | | | | | | |
Trial run| | | | | | | | | | | | | | |
Empty tank or check hose drai- nage| | | | | | | | | | | | | | |
Visual inspection of the sockets used.| | | | | | | | | | | | | | |
Testing of the RCD (ground fault cir- cuit interrupter).| | | | | | | | | | |
| | | |
1. Date: Signature| 2. Date: Signature| 3. Date: Signature| 4.
Date: Signature
---|---|---|---
5. Date: Signature| 6. Date: Signature| 7. Date: Signature| 8.
Date: Signature
9. Date: Signature| 10. Date: Signature| 11. Date: Signature|
12. Date: Signature
13. Date: Signature| 14. Date: Signature| 15. Date: Signature|
16. Date: Signature
Maintenance intervals:
Maintenance and service interval
| before each Commis- sioning| At De- mand| At least all
2 weeks| At least all 4 weeks| At least all 6 months| At least
annually
---|---|---|---|---|---|---
Check air inlet andoutlet and remove im- purities. (Fig 1, Fig 2.)| X| | | X|
|
External cleaning| | X| | | | X
Visual inspection of the water outlet (hose connection) for conta-mination| |
X| | | | X
Check air filter for dirt and foreign bodies, clean or replace if ne-cessary|
X| | X| | |
Check device for da- mage (power cable,housing, tank, fan wheel)| X| | | | |
Trial run| | | | | | X
Empty tank or check hose drainage| | X| | | |
Visual inspection of the sockets used.| X| | | | |
Testing of the RCD (ground fault circuit interrupter).| | | | X| |
Check air inlet and air outlet
The unit sucks in air from the front (Fig. 1) and blows it out from the side
(Fig. 2). Make sure that the air inlet and outlet are not blocked and check
this each time you use the unit. Make sure that no objects or walls obstruct
the air inlet or outlet and observe the distance rules.
Check the drainage hose:
Check the hose used for hose drainage regularly for blockages and damage. If
the hose is clogged or damaged, replace it with a new one.
Storage of the dehumidifier
If the dehumidifier is not used for a longer period of time:
- Switch on and disconnect the device.
- Empty the water tank completely and make sure that there is no more water in the appliance.
- Remove and clean the dust filters. Make sure that the filters are completely dry before reinstalling them.
- Bundle the power cable and attach it to the cable holder on the back of the device.
- Store the dehumidifier in a cool dry place. Keep the device away from direct sunlight, high/low temperatures and high dust exposure.
Check air filter:
This should be done every 2 weeks.
To do this, switch off the unit, disconnect the power cable and then
remove the front panel. The air filter is located on the inside of the front
panel.
Rinse the filter with warm (maximum 40°C) clear water and let it dry. Make
sure that the filter is not exposed to high temperatures and do not use
cleaning agents or other
substances (such as petrol or alcohol). You can then insert it back into the
front panel and reattach it to the unit.
Frequently asked questions (FAQ)
Current operating instructions can be found at: www.comedes.com
Device cannot be switched on.
- is the device correctly plugged in?
- is the water tank inserted correctly?
- is the tank full indicator lit up?
- did the fuse blow?
- is the room temperature above 35°C or below 5°C?
- is the timer function activated?
- if the above points are ok, try again in 10 minutes
- if the device is still not working, please contact service@comedes.com
The dehumidification capacity is too low.
- is the dust filter dirty?
- is the air inlet or outlet blocked?
- is the temperature or humidity too low?
The unit does not switch off in automatic mode.
- are the windows and doors closed?
- does a device produce steam in this room?
- Is the room too big?
The device is very loud.
- is the dust filter dirty?
- is it on firm, level and suitable ground?
- does the device touch the room wall?
- in the case of tiled floors, it is recommended to put a piece of carpet underneath.
Display messages:
Code | Cause | Follow | Solution |
---|---|---|---|
**** E1 | Temperature sensor defective. | Cycle: 30 minutesdehumidification, 15 | |
minutes defrosting. | Please contact us at: |
service@comedes.com
E2| Humidity sensor defective| Cycle: 30 minutesdehumidification, 15
minutes defrosting.| Please contact us at:
service@comedes.com
CL| Ambient temperature <5°C| Device switches off| Wait until the
temperature isback in the permitted working range.
**** CH| Ambient temperature >38°C| Device switches off| Wait until the
temperature isback in the permitted working range.
LO| Ambient air humidity <20| Device switches off| Wait until the humidity has
increased.
HI| Room air humidity ≥95%| Device continues to operate normally|
The fuse blows all the time.
****The RCD (FI) circuit breaker trips continuously. Stop operating and
contact us at:service@comedes.com
The power cord or plug becomes disproportionately warm.
****Stop the operation and contact us
atservice@comedes.com
There are objects or water in the device
Stop operating and contact us at:
service@comedes.com
Attention: Switch off and disconnect the device immediately and contact customer service if anything unusual happens
This product must not be disposed obf with household waste. This dehumidifier must be returned to a recycling point for electronic and electrical equipment. You can obtain further information about the relevant collection points from your local or city administration or from Comedes GmbH.
Dear customer,
Thank you for choosing the BTR 50 from Comedes GmbH.
You have purchased a powerful and reliable dehumidifier. To ensure that the device will be a faithful servant for a long period of time, we ask you to study the operating instructions, especially the safety instructions, thoroughly.
If you still have questions about the device after reading the operating
instructions, please do not hesitate to contact us:
E-mail address: service@comedes.com
If you provide your phone number, we will call you back free of charge.
We welcome any feedback from customers and would be pleased if you contact us.
With kind regards
Philip Thannhuber
Managing Director
Comedes Ltd
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>