The Crosby Group IPU10-3 CrosbyIP lifting clamp User Manual

June 10, 2024
The Crosby Group

**The Crosby Group IPU10-3 CrosbyIP lifting clamp

**

IP(U)10 Vertical lifting

IP\(U\)10 Vertical lifting

General

You have chosen a CrosbyIP lifting clamp.

CrosbyIP lifting clamps are the most reliable lifting clamps available. But using reliable tools does not automatically mean that practices are reliable. The people who work with clamps play an equally important role in reliable lifting. Ensure that everyone who works with CrosbyIP lifting clamps has been instructed in the proper application of the clamps.

CrosbyIP provides a 10 year warranty for its clamps. To keep CrosbyIP lifting clamps in optimum condition and keep warranty, regular maintenance is important. Preventive maintenance and repair shall be carried by a repairer authorized by CrosbyIP. In order to benefit from this warranty programme and for more details on maintenance procedures, please consult www.thecrosbygroup.com/resources/crosbyip-10-year- guarantee for more information.

Please read and understand these instructions before using the lifting clamp.

It is not permitted to stay in the danger zone of the load.

Ensure that the load remains on the ground when turning.

No changes may be made to CrosbyIP clamps. Never straighten, attempt to bend or heat treat parts.

Clamps suited for stainless steel, must be used only for handling stainless steel, to avoid contact corrosion.

Safety precautions

  • Proper instruction for the personnel is of vital importance. This will contribute to maximum reliability in the working environment.
  • IP(U)10 clamps may be applied per piece, per set or several at the same time for the lifting of plates.
  • Ensure that each clamp receives its proportionate share of the load. When using two clamps or more, a spreader beam is recommended.
  • Hardness: With the standard clamps it is possible to lift steel with a surface hardness of 363 HV10. With the clamps IP(U)10H steel up to a surface hardness of 472 HV10. For harder steel types contact your CrosbyIP Customer Service Centre.
  • Contact your CrosbyIP Customer Service Centre before using this clamp for plates and constructions that have a radius.
  • Temperature: the operating temperature is between –40 ºC (–40 ºF) and 100 ºC (212 ºF). For other temperatures contact your CrosbyIP Customer Service Centre.
  • There are restrictions for operation in special atmospheres (e.g. high humidity, explosive, saline, acid, alkaline).
  • Loads: For proper application of the clamp consult the load diagrams 1.
  • Ensure that all attachments between lifting eye and crane are properly fitted, secured and coupled.
  • For each lift only one plate may be transported or lifted.
  • The clamping yaws may not be placed on sloping or conical surfaces. Contact your CrosbyIP Customer Service Centre for assistance in selecting a clamp suitable for bevelled plates.
  • When the crane hook or attachment is too large and/or too heavy, use properly sized CrosbyIP 5000 stinger assembly or a chain sling with D-shackle of 75 cm (30 inch), with a strength that corresponds to the W.L.L. of the clamp. This will, when setting the load down, prevent the hook from descending to far allowing the clamp to open under the weight of the hook, or, in the case of an unprotected crane hook, its descending from the lifting eye. When suspending the clamp directly on the secured crane hook attention must be given to ensuring that the crane hook can move freely in the lifting eye. Ensure that the crane hook and other material is protected.
  • Remark: when handling the load, one should ensure that the load and or clamp does not encounter obstacles which could release the load on the clamps prematurely.
  • A clamp is a device that must be clean when used. Dirt has an adverse effect on the operation and also on the reliability of the clamp. When cleaning the clamp care should be taken to ensuring that moving parts are lubricated and the gripping surfaces are clean. Regular cleaning will enhance the life and reliability of the clamps.

Inspections protocols

Prior to every application of the clamp it is important the clamp operator inspects the clamp for proper functioning. Attention must be paid to the following (see illustration(s) 2 for part reference):

  • Ensure that the plate surface with which the clamp is to come into contact is free of scale, grease, oil, paint, water, ice, moisture, dirt and coatings that might impede the contact of the gripping surface with the plate.
  • Inspect pivot(s) (C) and camsegment (B) for wear and defects. The pivot(s) and teeth must be sharp and free of dirt.
  • Check the body (N) and the jaw for damage, cracks or deformation (this may indicate overloading). The clamp must open and close properly (when the operation of the clamp is stiff or heavy, it should be removed from operation for inspection).
  • Check the lifting eye (D) and camsegment shaft (G) for readily detectable wear and/or damage.
  • Check the spring (M). Press when the latch lever (A) is closed on the lifting eye (D). There should be clearly apparent spring tension. The clamp should, when the lifting eye is released, return to the closed position without problems.
  • Check whether the W.L.L. and the jaw opening stamped on the body corresponds with the load to be lifted. When this is no longer readable, remove the clamp from operation.
  • Always apply the minimum load, otherwise the load risks slipping out unintentionally.

Minimum load permitted:
5% of the W.L.L. applying to plate surface hardness up to 279 HV10.
10% of the W.L.L. applying to plate surface hardness up to 363 HV10.
For clamps IP(U)10H: 10% of the W.L.L. applying to plate surface hardness up to 472 HV10.
For clamps 0,5 IP(U)10: 5% of the W.L.L. applying to plate surface hardness up to 363 HV10.

The pivot(s) and the camsegment are the most critical parts in the clamp and require extra attention during inspection. Ensure in any event for good light during inspection. Observe the following rules during every inspection:
Pivot(s): Reject when the sharpness of one ring is damaged or worn for 50% or more.
Camsegment: Reject when the sharpness of one tooth is damaged or worn for 50% or more.

On the inside of the front cover illustrations have been included of damaged and worn (rejected) pivots and camsegments:

  1. One complete tooth not sharp and one damaged
    Inspections protocols

  2. Two teeth damaged for 50%
    Inspections protocols

  3. One tooth damaged for 100% and one tooth damaged for 50%
    Inspections protocols

  4. Two rings damaged for 100%
    Inspections protocols

  5. Interior ring damaged for 100%
    Inspections protocols

These areas of damage, precisely as wear, are not covered by the warranty.
In most cases however the areas of damage are much less extensive. In doubtful cases an authorised repairer should assess the clamp.

How to operate the clamp

DO NOT lift a clamp with load on the lifting brackets!

IP(U)10 lifting clamps are suitable for the lifting, turning and vertical transport of steel plates and structures. Lifting clamps with a Working Load Limit (W.L.L.) of 12 ton or more are equipped with lifting brackets on the body to place and to remove the lifting clamp horizontally on and from the load. For this operation, an auxiliary chain with hook attached to the master link is needed.

See illustrations 3 – 7 for part reference.

Instructions for use
Instructions for use

  1. Open the clamp by pulling the latch lever (A) towards the jaw (3).
  2. Place the clamp securely on the plate so that the jaw of the clamp rests on the plate (E) (4).
  3. Pull the latch lever (A) towards the lifting eye (D). The clamp will now close and will remain on the plate in pretensioned position, allowing lifting to commence (5).
  4. As soon as the load is at its destination let the crane hook descend until the clamp is fully free of load, meaning that the lifting chain is no longer taut and the lifting eye (D) of the clamp can move freely. To release the load pull the latch lever (A) towards the jaw, allowing the clamp to be and remain opened (6).
  5. The clamp may now be used again immediately or put away in opened position. This position will protect the teeth from damage (7).
  6. When the lifting brackets are used to place or remove the clamp from the load, be aware that the auxiliary hook is removed from the lifting bracket, allowing lifting to commence.

A reliable clamp, a secure basis for lifting

10 Year warranty preventive maintenance procedure:
During every maintenance service the most critical parts, being pivot(s), camsegment and spring are replaced and, when necessary, any rejected parts will be replaced.

10 Year warranty repair procedure:
During every repair service the most critical parts, being pivot(s), camsegment, spring, shafts and latch lever will be replaced and, when necessary, any rejected parts will be replaced.
For clamps with a Working Load Limit (W.L.L.) of 9 ton or more, parts will be replaced only when they no longer meet our standards.
Please consult www.thecrosbygroup.com/resources/crosbyip-10-year-guarantee for more
information on maintenance procedures.
Maintenance without 10 year warranty: Annually clamps are subjected to inspection and parts will be replaced only when they no longer meet our standards.
CrosbyIP authorised repairer

Explanation test certificate

EU Declaration of Conformity : We hereby declare that the equipment described at the front page conforms to the relevant fundamental safety and health requirements of the appropriate EU Directives, both in its basic design and construction as well as in the version marketed by us. This declaration will cease to be valid if any modifications are made to the machine without our express approval.

Relevant EU Directives: EU Machinery Directive (2006/42/CE) Applied standards: EN 13155 and ASME B30.20

UK Declaration of Conformity: We hereby declare that the equipment described at the front page meets the essential safety requirements of the Supply of Machinery (Safety) Regulations 2008 and section 6 of the Health and Safety At work Etc. Act. 1974. This declaration will cease to be valid if any modifications are made to the machine without our express approval.

Applied standards: EN 13155 and ASME B30.20
Manufacturer
CrosbyIP Lifting Clamps – Inter Product BV
Celsiusstraat 51
6716 BZ Ede
The Netherlands

Ede, 25-1-2021 W. Fabricius
Copyright © 2021 The Crosby Group LLC. All Rights Reserved.

WARNING

  • Loads may disengage from clamp if proper procedures are not followed.
  • A falling load may cause serious injury or death.
  • The clamp shall not be loaded in excess of its rated load or handle any load for which it is not designed. Read instructions in user manual to determine minimum load permitted and proper load thickness.
  • Never operate a damaged or malfunctioning clamp, or a clamp with missing parts.
  • Clamp not to be used for personnel hoisting.
  • Prohibition of handling above persons.
  • Do not leave suspended loads unattended.
  • Operator and other personnel shall stay clear of the load.
  • Do not lift loads higher than necessary.
  • Do not make alterations or modifications to clamp.
  • Do not remove or obscure warning labels.
  • See ANSI/ASME B30.20 BELOW-THE-HOOK LIFTING DEVICES for additional information.
  • Read, understand, and follow these instructions and the product safety information in user manual before using clamp.

Customer Service

Manufacturer:
CrosbyIP Lifting Clamps – Inter Product BV
Celsiusstraat 51
6716 BZ Ede
The Netherlands
Customer Service Centres

BELGIUM
Industriepark Zone B n°26
2220 Heist-op-den-Berg
P: (+32) (0)15 75 71 25
F: (+32) (0)15 75 37 64
[email protected]

UNITED KINGDOM
Station Street
Cradley Heath
West Midlands B64 6AJP
P: (+44) (0)1226 290 516
F: (+44) (0)1226 240 118
[email protected]

U.S.A
P.O. Box 3128
Tulsa, OK 74101
P: (+1) (918) 834 46 11
F: (+1) (918) 832 09 40
[email protected]

CANADA
1195 Courtney Park Drive East
Mississauga, Ontario
Canada L5T 1R1
P: (+1) 877 462 7672
F: (+1) 877 260 5106
[email protected]

The Crosby Group

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

The Crosby Group User Manuals

Related Manuals