ruck VENTILATOREN DHA EC CP 20 Roof Fan with Constant Pressure Control EC Motor Instruction Manual

June 10, 2024
ruck VENTILATOREN

ruck VENTILATOREN DHA EC CP 20 Roof Fan with Constant Pressure Control EC

Motor

Product Information

The DHA…EC CP 20 / …EC O CP S is a roof fan with constant pressure control that is manufactured in the European Union. It comes with a nameplate and meets several applicable standards, including DIN VDE 0100-100 and DIN EN 60204-1. The product is subject to constant quality controls and may be updated without prior announcement by the manufacturer.

Product Usage Instructions

Before using the DHA…EC CP 20 / …EC O CP S roof fan, please read the installation, operating, and maintenance instructions carefully, as well as the applicable documents listed in section 2.1 of the user manual. Ensure that the product is installed and operated correctly and only use it in perfect technical condition.

Check the device for any obvious defects and only use it in the power range specified in the technical data and on the nameplate. Ensure that protection against contact and being sucked in and safety distances are provided in accordance with DIN EN 13857. Electrical and mechanical protection devices should be provided by the client and safety components must not be bypassed or put out of operation. The product can only be operated by personnel with limited physical, sensory or mental capacities if they are supervised or instructed by responsible personnel. Children must be kept away from the product.

Remember that improper use may result in danger to life and limb or damage to the system or other property. If you have any questions about using the DHA…EC CP 20 / …EC O CP S roof fan, please refer to the installation, operating, and maintenance instructions or contact Ruck Ventilatoren GmbH for assistance.

FOREWORD

Dear customers,
Thank you for choosing our device.
Before operating the unit, please read carefully these installation, operating and maintenance instructions. If you have any questions, please contact: (Contact details see page 1)

The data provided in these installation, operating and maintenance instructions are for the product description only. A statement about a certain condition or a suitability for a certain application cannot be derived from our information. The information does not release the user from his own assessments and examinations.

All rights reserved by the manufacturer, even in the event of industrial property rights.
Any disposal such as copying and distribution rights lies with us.

IMPORTANT INFORMATION

This manual contains important information on the safe and appropriate assembly, transport, commissioning, operation, maintenance, disassembly and simple troubleshooting of the product.
The product has been manufactured according to the accepted rules of current technology.
There is, however, still a danger of personal injury or damage to equipment if the following general safety instructions and the warnings before the steps contained in these instructions are not complied with.

  • Read these instructions completely and thoroughly before working with the product.
  • Keep these instructions in a location where they are accessible to all users at all times.
  • Always include the operating instructions when you pass the product on to third parties.

Applicable Documents
The following documents and information on the exhaust fan must be observed in addition to the installation, ope-rating and maintenance instructions:

Other applicable standards

  • DIN VDE 0100-100
  • DIN EN 60204-1
  • DIN EN ISO 13857
  • DIN EN ISO 12100
  • VDMA 24186-1

Available documents at www.ruck.eu

  • Installation, operating and maintenance instructions
  • Programming instruction FU (three-phase version)
  • EC Declarations of conformity
  • EC-Declaration of Incorporation (Directive 2006/42/EC)
  • Commissioning report
  • Call to Tender
  • Dimensioned drawing
  • Technical drawing DWG
  •  Technical drawing DXF
  • 3D STEP

Provisions and regulations
When properly installed and operated, the device complies with the applicable standards and EU Directive at the time of its placing on the market.
In addition, observe generally valid, legal and other binding regulations of the European or national legislation as well as the regulations in your country for accident prevention and environmental protection.

Warranty and liability

Our devices are manufactured to the highest technical level in accordance with the generally accepted rules of techno-logy. They are subject to constant quality controls. Because the products are being constantly developed, we reserve the right to make changes to the products at any time and without prior announcement. We assume no liability for the correctness or completeness of these installation, operating and maintenance instructions.

To ensure your warranty claims, it is imperative to provide a commissioning report and a maintenance record.
Warranty and liability claims for personal injury and property damage are excluded if they are due to one or more of the following causes:

  • Improper use
  • Improper mounting, commissioning, operation and maintenance
  • Operating the device with defective and / or non-functional safety and protective devices
  • Failure to observe the instructions regarding transportation, installation, operation and maintenance
  • Unauthorized structural changes to the device
  • Poor monitoring and replacement of maintenance parts
  • Improperly performed repairs
  • Disasters and force majeure

GENERAL SAFETY INSTRUCTIONS

Planners, plant engineers and operators are responsible for ensuring that the product is installed and operated correc-tly.

  • Use our devices only in perfect technical condition.
  • Check the device for obvious defects, such as cracks in the housing or missing rivets, screws, caps or other applica-tion-relevant defects.
  • Only use the device in the power range specified in the technical data and on the nameplate.
  • Protection against contact and being sucked in and safety distances should be provided in accordance with DIN EN 13857.
  • Generally prescribed electrical and mechanical protection devices are to be provided by the client.
  • Safety components must not be bypassed or put out of operation.
  • The product may be operated by personnel with limited physical, sensory or mental capacities only if they are su-pervised or have been instructed by responsible personnel.
  • Children must be kept away from the product.

Intended use

Our devices are incomplete machineries as defined in the EU Machinery Directive 2006/42/EC (partly completed ma-chinery). The product is a not ready-for-use machine in terms of the machine directive.

It is intended exclusively for installation in a machine or in ventilation equipment and installations or for combination with other components to form a machinery or installation. The product may be commissioned only if it is integrated in the machinery/system for which it is designed and the machinery/system fully complies with the EC machinery di-rective.

Observe the operating conditions and performance limits specified in the technical data.
Conveying and ambient temperatures must be observed according to the technical data and the nameplate. Intended use also implies that you have fully read and understood this manual.

warning: Improper use may result in danger to the life and limb of the user or third parties or damage to the system or other property.

Improper use

Any use of the product other than described in chapter “Intended use” is considered as improper. The following points are improper and dangerous:

  • Delivery of explosive and flammable media or operation in potentially explosive atmospheres.
  • The conveyance of greasy and moist media (over 90% relative humidity).
  • Delivery of aggressive and abrasive media.
  • Operation without the duct system.
  • Operation with closed air connections.
  • The use on vehicles, aircrafts and ships.

Personnel qualifications

Assembly, commissioning, operation, disassembly and service (including maintenance and repair) require basic mecha-nical and electrical knowledge, as well as knowledge of the appropriate technical terms. In order to ensure operating safety, these activities may therefore only be carried out by qualified technical personnel or a person under the direc-tion and supervision of qualified personnel. Qualified personnel are those who can recognize possible hazards and institute the appropriate safety measures due to their professional training, knowledge, and experience, as well as their understanding of the relevant conditions pertaining to the work to be done. Qualified personnel must observe the rules relevant to the subject area.

Safety instructions in this manual

In this manual, there are safety instructions before the steps whenever there is a danger of personal injury or damage to the equipment. The measures described to avoid these hazards must be observed.

Safety instructions are set out as follows:

  • Safety sign (warning triangle)
    • Type of risk!
    • Consequences → Precautions
  • Draws attention to the risk.
  • Identifies the type or source of the hazard.
  • Describes what occurs when the safety instructions are not complied with.
  • States how the hazard can be avoided.

Safety sign (warning Consequence triangle)

General warning!
Indicates possible hazardous situations. Failure to observe the warnings may result in personal injury and / or damage to property.
Electricity warning (hazardous voltage)!
Indicates possible hazards due to electricity. Failure to observe the warnings may result in death, injury and/or damage to property.
Hot surface warning!
Indicates possible hazards due to high surface temperatures. Failure to observe the warnings may result in personal injury and/or damage to property.
Finger-Crushing Warning!
Indicates possible hazards due to moving and rotating parts. Failure to observe the warnings may result in personal injury.
Overhead load warning!
Indicates possible hazards due to overhead loads. Failure to observe the warnings may result in death, injury and/or damage to property.
Follow important information!
Instructions for safe, optimum use of the product

General warning
Failure to observe the warnings may result in personal injury and / or damage to property. Unauthorized repairs may cause personal injury and / or damage to property, in which case the manufacturer‘ s guarantee or warranty will not apply

Electricity warning (hazardous voltage)
Failure to observe the hazard may result in death, injury or damage to property. Before performing any work on conductive parts, always disconnect the unit completely from the electricity supply and make sure that it cannot be switchedback on again.

Caution! Burning hazard.
Failure to observe the hazard may result in personal injury and/or damage to property. Do not touch the surface until the motor and heater have cooled.

Never reach into the impeller or other rotating or moving parts.
Failure to observe the hazard may lead to serious injury. Work may only be performed once the impeller has come to a complete halt.

Never clean the internal space with flowing water or a high-pressure cleaner. Do not use aggressive or easily flammable products for cleaning (impellers/ housing). Only use mild soapsuds. The impeller should be cleaned with a cloth or brush.

ADHERE TO THE FOLLOWING INSTRUCTIONS

General instructions

  • Persons who assemble, operate, disassemble or maintain our devices must not be under the influence of alcohol, drugs or pharmaceuticals that may affect perception and responsiveness.
  • Responsibilities for the operation, maintenance and regulation of the product should be clearly determined and observed so that there can be no unclear areas of responsibility with regard to safety.

Indications assembly

  • Disconnect all of the product‘s poles from the mains before installing the product or connecting or removing plugs. Make sure that the product cannot be switched back on again.
  • Lay cables and lines so that they cannot be damaged and no one can trip over them.
  • Information signs must not be changed or removed.

Indications Commissioning

  • Make sure that all electrical connections are either used or covered. Commission the product only if it is installed completely.
  • The power switch must always be fully functional and easy accessible!

Indications during operation

  • Only authorized personnel is allowed to operate the setting mechanisms of the components or parts, under the provision that the system is used as intended.
  • In an emergency, or if there is a fault, or other irregularities, switch the equipment off and make sure it cannot be switched back on again.
  • The technical data given on the rating plate must not be exceeded.

PRODUCT INFORMATION

Description

  • Roof fan with constant pressure control
  • The temperature of the conveying medium of the individual types can be found in the technical data
  • Horizontal discharge
  • Backward curved radial impeller
  • Motor inside the airflow
  • Integrated thermal motor monitoring
  • Power switch integrated
  • Outdoor installation over heated rooms
  • Installation position vertical
  • Snow load class 0
  • Connection flange dimensions according to DIN 24154R3
  • The housing is made of plastic
  • Electronically commutated (EC) external rotor motor.
  • The roof fan with constant pressure control is used in ventilation sistems to maintain a constant set pressure level.
  • The constant pressure control is integrated in the air handling unit housing. It controls the fan speed to reach and keep the set-point of the differential pressure constant.

Nameplate

ATTENTION: The information on the nameplate must always be observed !ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-1

DELIVERY CONTENTS

  • 1 x roof fan with constant pressure control
  • 1 x Installation, operating and maintenance instructions
  • EC Declarations of conformity
  • EC-Declaration of Incorporation (Directive 2006/42/EC)

TECHNICAL DATA

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-
EC-Motor-fig-2

DIMENSIONS

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-3

TRANSPORT AND STORAGE

Transport and storage should only be performed by specialist personnel in accordance with the assembly and opera-ting manual and regulations in force.
The following points should be noted and followed:

  • Check the delivery according to the delivery note to ensure it is complete and correct and check for any damage. Any missing quantities or damage incurred during transport should be confirmed by the carrier. No liability is accep-ted if this is not observed.
  • For weight see technical data
  • It should be transported with suitable lifting equipment in the original packaging or on the transport equipment indicated.
  • If transported with a forklift, it should be ensured that the product is resting with the basic profile or base frame completely on the forks or on a pallet and the product‘s centre of gravity is between the forks.
  • The driver must be authorized to drive a forklift.
  • Do not go beneath the suspended load.
  • Avoid damage or deformation of the housing.
  • The product must be stored in a dry area and protected from the weather in the original packaging. Open pallets should be covered with tarpaulins. Even weatherproof modules should be covered because their weather resistan-ce is only guaranteed after complete installation. If moisture has penetrated into the original packaging, remove it immediately.
  • Storage temperature between +5 °C and +40 °C. Avoid severe temperature fluctuations.
  • If the product has been in storage for more than a year, check the smooth running of impellers and valves by hand.

ASSEMBLY

Assembly work may only be performed by specialist personnel in accordance with the installation and operating ma-nual and the regulations and standards in force.

The following points should be noted and followed:

  • The foundation must be even and levelled. It must not exhibit unevenness or a slope in any direction.
  • Set up and align the machine with the aid of a water level. A perfect function of the device can be guaranteed only if levelled mounted.
  • Only suitable installation aids, in accordance with regulations, should be used.
  • The device must be installed in such a way that it is easily accessible for maintenance and cleaning purposes.
  • The unit should only be installed with authorized and suitable fastening materials at all fastening points.
  • Do not distort the unit when installing.
  • Just use the indicated mounting and fixing places. No holes should be made in the housing or any screws screwed into it.
  • The duct system must not be supported on the housing.
  • For structure-borne sound decoupling, a flexible connection is recommended when connected on a duct system.
  • The length of straight tube before fan must be at least 2.5 times the fan diameter
  • The pressure measurement hose is placed in the duct to be controlled (va- cuum side). Check leak tightness while installing.ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-Motor-fig-4
  1. Cover
  2. Constant pressure control
  3. Mounting screws
  4. Roof fan
  5. Connection cable
  6. Pressure measurement hose
  7. Roof socket (Accessories)

Mounting on roof socket (DSF)ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-
with-Constant-Pressure-Control-EC-Motor-fig-5

  • Fasten the roof fan (2) with screws and washers (3) and (4) on the roof socket (1)

Mounting of electrical connectionruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-
with-Constant-Pressure-Control-EC-Motor-fig-6

Connection power supply:

  • Release screws (1)
  • Remove cover (2)
  • Perform the wiring according to the terminal diagram

Installation examples

DSF – Flat roof socket / Sloped roof socketruck-VENTILATOREN-DHA-EC-CP-20
-Roof-Fan-with-Constant-Pressure-Control-EC-Motor-fig-7Illustrations exemplaryruck-
VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-Motor-
fig-8DSS – Socket silencer / Sloped roof socket silencerruck-VENTILATOREN-DHA-EC-CP-20
-Roof-Fan-with-Constant-Pressure-Control-EC-Motor-fig-9Illustrations exemplaryruck-
VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-Motor-
fig-10

ELECTRICAL CONNECTION

Electricity warning (hazardous voltage): F ailure to observe the hazard may result in death, injury or damage to property. Before performing any work on conductive parts, always disconnect the unit completely from the electricity supply and make sure that it cannot be switched back on again

The electrical installation may only be carried out by qualified electricians in compliance with the installation, operating and maintenance instructions and the applicable national regulations, standards and guidelines:

  • ISO, DIN, EN and VDE specifications, including all safety requirements.
  • Technical connection conditions.
  • Safety at work and accident prevention requirements.

This list does not claim to be complete.
Requirements should be applied under one‘s own personal responsibility.

  • The electrical connections must be made as shown in the corresponding wiring diagrams and terminal diagrams.
  • The type of cable, size of cable and method of laying should be determined by an authorized electrician.
  • Low and extra-low voltage cables should be laid separately.
  • If no repair switch is integrated in the device, an all-pole mains disconnecting switch with min. 3 mm contact opening must be provided in the supply line.
  • Use a separate cable inlet for each cable.
  • Any cable inlets that are not used must be sealed so that it is airtight.
  • All cable inlets must have strain relief.
  • Create equipotential bonding between the unit and the duct system.
  • Check all protective measures after the electrical connection work (earthing resistance, etc.)
  • Motor current and motor power must not exceed the values stated on the motor nameplate. The specified max. fan speed must never be exceeded, otherwise the motor and fan will be destroyed by this overload and dissolved or flying parts can destroy other components.

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-11

  • X3, X4 Open: day-time operation
    Closed: night-time operation

  • 7. X5, X6 Open: regulator OFF Closed: regulator ON

  • Set-point: day 10-990 Pa

  • Set-point: night 10-990 Pa

Only potential-free contacts may be connected at terminals X3 and X4, and X5 and X6. Applying an external voltage can seriously damage the regulator.
The regulations for safety extra-low voltages must be observed.

info: The maximum pressure in a ventilation plant must not exceed 5000 Pa. This would result in severe damage to the regulator. Low voltage control leads must be installed so that they are separated from mains leads.

Unit supply cable / Electrical connection / wiring diagram
Connect the mains supply cable as shown in the wiring diagram. For the dimensioning of the line, observe the unit‘s rating plate and the relevant guidelines. Appropriate protection with correctly dimensioned automatic safety breakers (circuit protection breaker) must be provided.

The device must be connected according to the wiring diagram. For fans which are controlled by external control de-vices, the corresponding operating instructions of the manufacturer must be observedruck-VENTILATOREN-DHA-EC-
CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-Motor-
fig-12

Thermal motor protection
During operation, electric motors heat up. Under certain circumstances (excessively high ambient or fluid temperatu-res, heavy contamination, etc.), the motor temperature may exceed the safety limit of the electrically isolated parts.
In case of EC motors an electronic temperature monitoring is present.

Fault current protection switch
If a fault current protection switch is used, only AC/DC sensitive RCD protective devices (type B or B+) are permitted.

warning: Even when the device is switched off, voltage is applied to terminals and connections. Do not touch the de-vice for 5 minutes after all- pole disconnection from the mains.

COMMISSIONING

warning: Commissioning by trained technical personnel may only be performed after any risk has been ruled out. The following checks should be performed in accordance with the installation and operating manual and the regu-lations in force:

  • Correctly sealed installation of the unit and duct system.
  • Check the duct system, unit and medium lines, if present, remove any foreign bodies if necessary.
  • The intake opening and inflow into the unit must be clear.
  • Check all mechanical and electrical protection measures (e.g. earthing).
  • Voltage, frequency and type of current must correspond with the rating plate.
  • The pressure measuring tube will be laid in the duct.
  • Setting of the desired differential pressure see 13. Operation

OPERATION

Operation without a control unit

CAUTION: Isolate electrical installation

Adjust set-point
After removing the cover, you have free access to the pressure regulation circuit board. Adjust set-point for the desired differential pressure at the two upper decade switches (8).
Switching the regulator on and off
Bridging terminals X5 and X6 switches the constant pressure regulator CON P1000 on, and removing the bridge swit-ches it off again.
Turning the night mode ON and OFF
By bridging the terminals X3 and X4 the night mode is switched on, by removing the bridge, it is switched off.
Changing day-time set-point
Adjust set-point Day with the decade switches (8). e.g. 3 2 = 32 x 10 = 320 Pa
Adjusting the night-time set-point
Adjust set-point Night with the decade switches (9). e.g. 4 1 = 41 x 10 = 410 Paruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-13

Operation with a control unit (optionally)

ATTENTION: When disconnecting the control unit from the unit after programming, the adjusted set-points will be deleted. The manually adjusted setpoints by the rotary switch will then apply.

The control unit is used for controlling and entering various functions. The display shows the various operating parame-ters and error messages. You can select individual menu points or change values with the various buttons.

1) Mode Button
Switches to the control unit parameter menu.
2) ON/OFF Button
Button for switching the unit on or off or switching to menu ma-nagement.
A) Button A
Buttons for increasing and decreasing the set-point for “DAY”
B) Button B
Buttons for increasing and decreasing the set-point for “NIGHT”
3) Control cable
4) Displayruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-
Control-EC-Motor-fig-14 Adjustment of the control unit parameter

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-16

Menu functions

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-17

Parameter settings Menuruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-
Constant-Pressure-Control-EC-Motor-fig-18

You move to the parameter settings menu menu P by pressing the ON/OFF button, which must be held down for approx. 10 seconds.
Parameter P01 is displayed on the screen. With the A (▲ and ▼) buttons on the control unit, the individual P parameters can be called up. Press the „mode button“ (M) once to return to the starting function.

P 1 Minimum set-point on control unit

  • Parameter for display and setting of the minimum set-point.
  • The setting range is from 10 Pa to 500 Pa.
  • The parameters can be changed with the buttons B (▲ and ▼).

P 2 Maximum set-point on control unit

  • Parameter for display and setting of the maximum set-point.
  • The setting range is from 100 Pa to 990 Pa.
  • The parameters can be changed with the buttons B (▲ and ▼).

P 3 P – component

  • The setting range is from 5 to 15. 05 = no gain 10 = average gain 15 = high gain
  • The parameters can be changed with the buttons B (▲ and ▼).
  • The works setting is 5.
  • The regulation tends to pulsate at high gain.

P 4 Pressure correction

  • The works setting is “0”.
  • The parameters can be changed with the buttons B (▲ and ▼).
  • Settings between -20 Pa and +20 Pa are possible.

P 5

  • Control of the decade switches for Day and Night.
  • The current program version is listed below „P05“.
Operation with Modbus communication interface

Wiring diagram

To activate Modbus operation, jumper J2 must be set as shown in the following figure.

Interface information
The device works as a Modbus RTU slave. The interface configuration is 8N1, 9600Baud, slave address 1. The address and the baud rate can be set, see the following figure. As bus line is recommended a twisted pair data cable with 120 Ohm impedance.ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-
Pressure-Control-EC-Motor-fig-20

Functions implemented

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-21ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-
Control-EC-Motor-fig-22

Parameter table

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-23ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-
Control-EC-Motor-fig-24

Example for switching on and off:

  • To switch on, 128 (decimal) must be written into register 33 (status and control word).
  • To switch off, 64 (decimal) must be written into register 33 (status and control word).

Current value table

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-25

Current value table, protocol addresses 24 (error numbers)

Value

  1. Reserved
  2. Reserved
  3. Reserved
  4. Reserved
  5. Reserved
  6. Reserved
  7. Reserved
  8. Reserved
  9. Reserved
  10. Reserved
  11. Fan defective
  12. Reserved
  13. Reserved
  14. Reserved
  15.  Reserved
  16. Reserved
  17. Reserved
  18. Reserved
  19. Reserved
  20. Reserved
  21. Reserved

MAINTENANCE AND CLEANING

Servicing, troubleshooting and cleaning may only be performed by specialised personnel in accordance with this installation and operating manual and the regulations in force.

  • Make sure that no connections or components are loosened unless the device is disconnected from the mains. Make sure that the equipment cannot be switched back on again.
  • Individual components must not be interchanged. For example, the components intended for one pro-duct may not be used for other products.
  • The regular maintenance and care of our devices is designed to ensure proper function, value retention and avoidance of damage. Keep a maintenance log.
  • Perform the specified maintenance on the unit at the specified intervals.

Our devices require little maintenance when operated properly.
The following work should be performed at regular intervals, in accordance with health and safety regulations:

  • Check the operation of the control system and safety devices.
  • Check electrical connections and wiring for damage.
  • Remove any dirt from the fan impeller or impellers and from inside the fan housing in order to prevent any unba-lance or reduction in output.
    • Do not use aggressive or easily flammable products for cleaning (impellers/housing).
    • Preferably only water (not flowing water) or mild soapsuds should be used.
    • The impeller should be cleaned with a cloth or brush.
    • Never use a high-pressure cleaner.
    • Balancing clips must not be moved or removed.
    • The impeller and fittings must not be damaged in any way.
  • Pressure fittings and hoses should be checked regularly for impurities and, if necessary, they should be cleaned, respectively the pressure hoses should be replaced.

Before putting the unit back into operation after maintenance and servicing work, carry out a visual inspection as described in section 11. and 12.

Checklist Maintenance and Service

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-26

LIFETIME AND DISPOSAL

Product life

The motors are equipped with maintenance-free, permanently lubricated ball bearings. Under normal operating condi-tions, the expected lifetime is about 30,000 operating hours.
The information given here depends strongly on the respective field of application as well as the environmental condi-tions. We recommend replacing these fans after reaching about 30,000 operating hours or 5 years.

Decommissioning and disposal

warning: When disassembling, parts under voltage are exposed, which can lead to electric shock when touched. Before dismantling, disconnect the fan from all poles of the mains and secure against being switched on again!

Parts and components of the device that have reached their lifetime, e.g. due to wear, corrosion, mechanical stress, fatigue and/or all other, not directly recognizable effects, must be disposed of professionally and properly after disas-sembly in accordance with national and international laws and regulations. The same applies to excipients in use such as oils and fats or other substances. The conscious or unconscious reuse of used components such as e.g. impellers, rolling bearings, motors. etc. can lead to a risk to persons, the environment as well as machinery and equipment. The applicable local operating regulations must be observed and applied.

Spare parts (motor + impeller)

  • Only original spare parts may be used.
  • The repair may only be carried out by personnel trained and authorized.

TROUBLESHOOTING

  • Further faults may occur before and during operation of the unit which are not indicated by an error message on the display.
  • If the fan stops due to a malfunction, please disconnect all poles of the fan from the power supply.
  • Please then check whether there is an obvious fault (blocked impeller, damage, etc.) and rectify it. If there are no obvi-ous faults, you can reconnect the fan to the mains after waiting for approx. 1 minute.

ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-Control-EC-
Motor-fig-27ruck-VENTILATOREN-DHA-EC-CP-20-Roof-Fan-with-Constant-Pressure-
Control-EC-Motor-fig-28If there is still no function, please proceed according to the following table:

Information updated

  • print 17.11.2022
  • mdar_pb_16d_k10001_en
  • We reserve the right to make changes

ruck Ventilatoren GmbH

  • address: Max-Planck-Str. 5 D-97944 Boxberg-Windischbuch
  • Tel. +49 7930 9211-300
  • Fax +49 7930 9211-166
  • info@ruck.eu
  • www.ruck.eu