Jetec ELECTRONICS JTC-X40A-WL Remote Parameter Setting Temperature Humidity or CO2 Large Display User Manual
- June 4, 2024
- Jetec ELECTRONICS
Table of Contents
Jetec ELECTRONICS JTC-X40A-WL Remote Parameter Setting Temperature
Humidity or CO2 Large Display
Thank you for purchasing JTC-X40A-WL remote configuration version-LED temperature and humidity display, please read the instruction manual before use and follow precautions to ensure the most optimal performance and to avoid unnecessary damage. Damage caused by man-made improper use will not be warranted.
Warning| Don’t disassemble, repaire or modify display or sensor by yourself
For maintenance matters, please contact the sales store or the company.
---|---
Warning| Do not let this product been dropped, or subjected to an impact force
It may cause screen damage, breakage and failure.
Warning| When wiring, follow the label on the wiring terminals
It may cause electric shock or malfunction.
In order to improve the contents of the operating manual, the company has authority to amend it without notice.Shipment is subject to physical。
Instrument Description
Display instructions
Normal Mode | 3-digit Display(Humidity does not contain decimal points) |
---|---|
Setting Function | 3-digit or 4-digit display |
RED LED | Display value reach the color conversion upper limit |
GREEN LED | Normal display value |
Red and Green Alternation | The display value has reached the upper / lower |
alarm
Wiring Instructions
Parameter Setting Dscription
Item | Set values | Explanation |
---|---|---|
Device Name | Can define Chinese/English name of the device | |
Alarm | ON / OFF | Only for buzzer models |
First row decimal point | ON / OFF | Only 4 ~ 20mA, 0 ~ 5V, 0 ~ 10V Output |
Sensor models
※ If the decimal point is changed, the maximum and
minimum range should be reset.
First row maximum range| -999.0 ~ 999.0
First row minimum range| -999.0 ~ 999.0
First row correction| -999.0 ~ 999.0|
Standard models (JTC-X40A):
Correction value, upper and lower alarm setting and color conversion value refer to table 1
First row upper limit| -999.0 ~ 999.0
First row lower limit| -999.0 ~ 999.0
First row color conversion| -999.0 ~ 999.0
Second row decimal point| ON / OFF| Only 4~20mA, 0~5V and 0~10V Output
Sensor models
※ If the decimal point is changed, the maximum and
minimum range should be reset
Second row maximum range| -999.0 ~ 999.0
Second row minimum range| -999.0 ~ 999.0
Second row correction| -999.0 ~ 999.0|
Standard models (JTC-X40A):
Correction value, upper and lower alarm setting and color conversion value refer to table 1
Second row upper limit| -999.0 ~ 999.0
Second row lower limit| -999.0 ~ 999.0
Second row color conversion| -999.0 ~ 999.0
Third row decimal point| ON / OFF| Only 4~20mA, 0~5V and 0~10V Output
Sensor models
※ If the decimal point is changed, the maximum and
minimum range should be reset
Third row maximum range| -999.0 ~ 999.0
Third row minimum range| -999.0 ~ 999.0
Third row corrections| -999.0 ~ 999.0|
Standard models (JTC-X40A):
Correction value, upper and lower alarm setting and color conversion value refer to table 1
Third row upper limit| -999.0 ~ 999.0
Third row lower limit| -999.0 ~ 999.0
Third row color conversion| -999.0 ~ 999.0
Recording interval| Hours/Min/sec| 30 seconds to 1 hours
Table I . JTC-X40A-WL Standard models
JTC-X40A- WL | Temperature | Humidity | CO2 |
---|---|---|---|
Correction value | -5.0~5.0 ℃ | -10~10%RH | -100 ~ 100 |
High alarm | -10~65°C | 0~99%RH | 0 ~ 5000 |
Low Alarm | -10~65°C | 0~99%RH | 0 ~ 5000 |
LED color conversion values | -10~65°C | 0~100%RH | 0 ~ 5000 |
When recording, if parameter is changed, the record will be stopped.
When recording, if the “record interval” is modified, record will stop and
previous data will be cleared, but the downloaded data will not be affected.
iOS APP Operating instructions
Connection mode
Go to the app Store, search for Jetec remote or scan QR code to install app
- Before starting the APP setting, please turn on the Bluetooth function and confirm that the large display device has been powered on and displayed normally.
Step 1
Open APP and click “search device”
Step 2
From the device list, click the device name you want to set
Step 3
When the administrator first login, please input default password 000000,
which can be revised during “modifying the password” function
Function List
| ****
Storage List
| 1. Store current set value, different settings can be stored to a different list
2. Slide the stored list to left can rename or delete
Save Set up
---|---|---
|
Import settings
| When the stored values are applied, the current settings will be overwritten
※ When recording, import setting will make recording stop
|
Modify password
| When first time change administrator password, default password is 000000
| ****
Download *
record
| 1. Click this key to “start recording”, “End record”, if there is a record file can “download record” Start Record
Download record
cancel
※ Pressing the start record clears the current record data, but the downloaded data is not affected
※ Press the download record to overwrite the “downloaded log file”.
Once it is overwritten, it will not be able to recover. Please export the file and back up in advance
※ When downloading files, avoid obstacle between your phone and your device so as not to affect connection quality and cause file errors or download failures
2. The maximum number of records is 6000. You can download
the data based on per 1000 unit Get DataLog
※ When recording number up to 6000, recording will stop automatically
| ****
Record *
chart
| After downloading the record, click this button to view the graph, below can choose “Select graph”, “Table” and “Export log”
● Select Graph You can view the graph and choose to display the first
row, second row, third row, individually or simultaneously
Select Graph
Analog 1 Analog 2 Combination
cancel
● Table Display detailed record data
Date and time, record number, data of each row, and can do condition screening
● Export Log The record file can be downloaded as a PDF or. csv file
Records can be sent and shared by various means, such as message, mail, etc., or can be wirelessly connected to printer to print PDF files.
---|---|---
Andriod APP Operating instruction
Connection mode
Go to Google Play, search for Jetec remote and install the app
- Before starting the APP setting, please turn on the Bluetooth function and confirm that the large display device has been powered on and displayed normally.
- If the keyboard is not working properly (for example, you cannot enter a decimal point … , etc.), download the world-ready “google keyboard to the Google Play Store
Step 1
Open the app and click “Search Device”
Step 2
You will be asked to turn on positioning to allow app entering, please click
OK
Step 3
The first time you use the Jetec Remote APP, you will be asked to turn on the
Bluetooth , please click “Allow”
As long as the Bluetooth function turned on, the inquiry will not appear for
subsequent use.
Step 4
From the device list, click the device name you want to set
Step 5
When the administrator first login, please input default password 000000,
which can be revised during “modifying the password” function
User default password is 111111,
(This password can only for parameter reading, can not set)
Function List
| ****
Storage settings
| Store current set value , different settings can be stored to a different list
---|---|---
|
Import settings
| When the stored values are applied, the current settings will be overwritten.
※ When recording, import settings will sopt the recording
| ****
- Data download
| Click this button to download the record data and view it in the “display chart”
※ Press the data download will overwrite the downloaded log file, once it is covered, it will not be able to recover. Please export the record files you want in advance
Warning! It will stop the record and start downloading.
CANCLE OK
※ When downloading files, if the number of downloads is not the same as
the total number of records, it means that the download is incomplete.
Please press YES and download it again
---|---|---
| ****
- Display charts
| After downloading the record, click this button to view the graph, below can choose “Select graph”, “Table”, “Export log” and “Report”
●Dialog Graph can be display individually as first/second/third row or display simultaneously
| | ● List Data Detailed record data can be displayed: date and time, record number, row of data, and condition screening
● Export Record files can be downloaded as . csv or PDF file
Data report
Choose the export method
NO PDF CSV
Records can be sent and shared by various means, such as message, mail, etc., or can be wirelessly connected to printer to print PDF files
● Report PDF report can be viewed online
---|---|---
|
Modify password
| When first time change administrator password, default password is 000000
| Start recording| Pressing the start record will clears the
current record data, but the downloaded data is not affected.
Report picture
PDF Report
CSV Report
TEL:+886-4-23729418
FAX:+886-4-23724011
www.jetec.com.tw
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>