Altronix NetWay8G PoE Managed Midspan Solution Installation Guide

June 4, 2024
Altronix

More than just power. TM

Power over the Ethernet

NetWare G Series
PoE Managed Midspan Solution for Standard Network Infrastructure

Models Include:
NetWay8G
– Eight (8) Port PoE Midspan Injector
– 240W total power

NetWay8GP

 – 8-Port Managed Hi-PoE Midspan Injector

 – 480W total power

NetWay16G

 – Sixteen (16) Port PoE Midspan Injector

 – 480W total power

Installation Guide

DOC#: NETG Rev. 050719

Installing Company: _
Service Rep. Name: ____
Address: ___

Phone #: __

Overview:

Altronix NetWay8G, NetWay8GP, and NetWay16G Networked Managed Midspans provide PoE/PoE+/Hi PoE (up to 60W) power per port, and pass data at 10/100/1000  Mbps at distances up to 100m. Features also include an integral battery charger for applications requiring backup and embedded LINQ Technology to monitor, control, and report power and diagnostics from anywhere.

Features:

Agency Listings: Battery Backup:

• UL 60950-1 Information Technology Equipment.
• CE European Conformity.
Input:
• NetWay8G: 115VAC, 60Hz, 3.25A or 230VAC, 50/60Hz, 2.0A.
• NetWay8GP/16G: 115VAC, 60Hz, 5.5A or 230VAC, 50/60Hz, 3.0A.
Power:
• Unit supplies PoE output voltage (55V).
Total power:
NetWay8G (up to 30W per port): 240W.
NetWay8GP (up to 60W per port): 480W.
NetWay16G (up to 30W per port): 480W.
• IEEE 802.3af and IEEE 802.3at compliant (PoE/PoE+/60W).
• Short circuit protection.
Ethernet:
• Eight (8) or sixteen (16) ports for cameras/edge devices over ethernet.
• Wire type: 4-pair CAT5e and higher.
• Speed: 10/100/1000 Mbps.
Functions:
• Auto detection and protection of legacy non-PoE cameras/edge devices.| • Built-in battery charger (optional rack mount battery enclosure -RE2).
• Automatic switchover to stand-by battery when AC fails.
LINQ Technology:
• SSL (Secure Socket Layer) security encryption.
• User-level security.
• Built-in IP management allows for remote camera reset and monitoring.
• Provides local and/or remote access to critical information via LAN/WAN
• Email and Windows Dashboard Alert notifications report real-time diagnostics.
• Event log tracks history.
Accessories:
NetWayXT:
• PoE repeater module extends data range 100m.
NetWayXTX:
• PoE/PoE+ repeater module extends data range 100m.
RE2:
• Rack Mount Battery Enclosure accommodates up to four (4) 12VDC/7AH batteries

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. NetWayG unit is not intended to be connected to outside plant leads. These products are for indoor use only and must be installed within the protected premises. If the battery bracket is removed, then the unit must be installed in a restricted access area (Fig. 1b, pg. 3).Altronix NetWay8G PoE Managed
Midspan Solution

  1. Attach mounting brackets to NetWayG unit for rack or wall mount installation (Fig. 5 or 6, pg. 8). Affix rubber pads to NetWayG for shelf installation (Fig. 7, pg. 8).

  2.  Secure the unit in a rack or on a wall, or place the unit on a shelf as desired.
    Note: The following factors should be taken into consideration when installing these rack mount units:
    a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).
    b. Take care to ensure that there is sufficient airflow around the unit and that obstructions do not impede it.
    c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.

  3. Plug the grounded AC line cord (included) into the IEC 320 connector of the NetWayG unit (Fig. 2g, pg. 4). Plug the unit into the reliable earth-grounded socket. When using multiple units, the sum of the individual nameplate ratings should not exceed the supply circuit rating.
    Do not connect to a receptacle controlled by a switch.

  4. Connect structured cables from port marked [IN] on NetWayG to the corresponding inputs of an ethernet switch or video server (Fig. 2b, pg. 4, Fig. 4, pg. 6).
    Note: All cabling and wire must be UL Listed and/or Recognized wire suitable for their application.

  5. Connect structured cables from port marked [OUT] on NetWayG to PoE-compliant camera/edge devices (Fig. 2a, pg. 4, Fig. 3, pg. 5).

  6. When the use of stand-by batteries is required, they must be sealed lead acid or gel type. Connect four (4) 12VDC batteries in series to terminals marked [+ BAT –] (Fig. 2h,  pg. 4), carefully observing polarity.
    Note: When batteries have not been used a loss of AC will result in a loss of output voltage.

  7. Manual Reset NetWay8G/NetWay8GP:
    Depress button for 3 seconds via pinhole marked RESET on front of the unit.
    Manual Reset NetWay16G: This will require opening the unit.
    CAUTION: Disconnect 115/230VAC prior to the opening of the unit. To manage network settings via USB, or reset to factory default settings via the reset button proceed to open the top of the enclosure chassis removing screws (set screws aside). Plug the laptop into a USB port to manage and review network settings via Altronix  Dashboard as needed. To restore to factory default via manual reset, proceed to open the unit as described above and depress the reset button (for 3 secs.) located on board. Close enclosure with screws and power unit once again

Altronix NetWay8G PoE Managed Midspan Solution - fig

2a OUT 1-8 (1-16): Structured cable to PoE-compliant cameras/edge devices.
2b IN 1-8 (1-16): Structured cable to an ethernet switch or video server.
2c LED(s) 1-8 (1-16): Port status LEDs.
2d Manual Reset: Restores unit to factory settings.
NetWay8G/NetWay8GP: Located on the front of the unit.
NetWay16G: Located internal (refer to installation instructions above)
2e USB Port
NetWay8G/NetWay8GP: Located in the front of the unit.
NetWay16G: Located internal (refer to installation instructions above)
2f Ethernet Port
2g IEC 320 Connector: 115/230VAC (grounded line cord included).
2h Built-in battery charger: Charges stand-by batteries for applications requiring backup, (optional rack mount battery enclosure available – RE2)

NetWay16G

Altronix NetWay8G PoE Managed Midspan Solution - fig1 NetWayG Installation Guide

Technical Specifications:

Parameter Description

No. of Ports

| NetWay8G:       Eight (8) PoE/PoE+ Ports (10/100/1000 Mbps). NetWay8GP: Eight (8) PoE/PoE+/Hi-PoE Ports (10/100/1000 Mbps). NetWay16G:     Sixteen (16) PoE/PoE+ Ports (10/100/1000 Mbps).
Input Power Requirements| NetWay8G:       115VAC, 60Hz, 3.25A or 230VAC, 50/60Hz, 2.0A. NetWay8GP:     115VAC, 60Hz, 5.5A or 230VAC, 50/60Hz, 3.0A. NetWay16G:     115VAC, 60Hz, 5.5A or 230VAC, 50/60Hz, 3.0A.
Indicators| Port Status LEDs.


Environmental Conditions

| Operating Ambient Temperature:        – 20ºC to 50ºC (– 4ºF to 122ºF). Relative Humidity:   85%, +/– 5%.
Storage Temperature:                            – 20ºC to 70ºC (– 4ºF to 158ºF).
Operating Altitude:                             Up to 2,000m.


Weights (approx.)

| NetWay8G| NetWay8GP| NetWay16G
Product Weight: 6.06 lb (2.75 kg).

Shipping Weight: 8.0 lb. (3.63 kg).

| Product Weight: 6.06 lb (2.75 kg).

Shipping Weight: 8.0 lb. (3.63 kg).

| Product Weight: 6.06 lb (2.75 kg).

Shipping Weight: 8.0 lb. (3.63 kg).

Fig. 3 – NetWayXTGAltronix NetWay8G PoE Managed Midspan Solution -
fig2

Installing a NetWayXTG Repeater Module:
NetWayXTG will work with PoE/PoE+ devices.
NetWayXTG is not intended to be connected to outside plant leads.

  1. Mount NetWayXTG in the desired location utilizing the mounting hole (Fig. 3a, pg. 5). Use a proper fastener and/or wall anchor when securing NetWayXTG to the wall.
  2. Connect the structured cable from port marked [OUT] on NetWayG to port marked [IN] on the NetWayXTG (Fig. 3b, pg. 5).
  3. Connect the structured cable from the port marked [OUT] on NetWayXTG to the PoE camera/ device or the next NetWayXTG repeater (Fig. 3b, pg. 5, Fig. 4, pg. 6 ).
  4. Port status LEDs will illuminate on NetWayXTG indicating the port is operational (Fig. 3a, pg. 5, refer to Port LED definitions below).

Port LED Definitions for NetWayXTG Repeater:

Status PoE/PoE+ Output LED Green LED Yellow LED
OFF No PoE/PoE+ Output Indicates no link. Indicates no link
ON Normal PoE/PoE+ Output Indicates 1G link Indicates 10/100 link
Blinking Indicates 1G activity Indicates 10/100 activity

NetWayG Typical Applications:
NetWay8G is shown (similar to NetWay8GP). NetWay16G is similar with twice as many ports

Altronix NetWay8G PoE Managed Midspan Solution - fig3

The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.

CAUTION: To reduce the risk of electric shock do not open the enclosure. There are no user-serviceable parts inside. Refer servicing to qualified service personnel.

Configuring NetWayG for Network Connection
Please be sure to visit altronix.com for the latest firmware and installation instructions
Factory Default Settings

  • IP Address: 192.168.168.168
  • User Name: admin
  • Password: admin
  1. Set the static IP address for the laptop to be used for programming to the same network IP address as the NetWayG. The default address of the NetWayG is 192.168.168.168, E.I. 192.168.168.200.
  2. Connect one end of the network cable to the network jack on the NetWayG and the other to the network connection of the laptop.
  3. Open a browser on the computer and enter “192.168.168.168” into the address bar. A dialog box Authentication Required will appear requesting both user name and password. Enter the default values here. Click on the button labeled Log In.
  4. The status page of the NetWayG will appear. Click on the tab labeled Network Settings. This will open the Network Setting screen. In this screen, the MAC Address of the  NetWayG module will be found along with the Network Settings and Email Settings.

Network Settings:
In the IP Address, the Method field selects the method that the IP Address for the NetWayG will be obtained (STATIC or DHCP), then follow the appropriate steps.
Static:
A. IP Address: Enter the IP address assigned to the NetWayG by the network administrator.
B. Subnet Mask: Enter the Subnet of the network.
C. Gateway: Enter the TCP/IP gateway of the network access point (router) being used (gateway configuration is required to properly receive emails from the device).
D. HTTP Port: Enter the HTTP port number assigned to the NetWayG module by the network administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.
E. HTTPS Port: Enter the HTTPS port number assigned to the NetWayG module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access.
F. Click the button labeled Submit Network Settings. A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.

DHCP:
A. After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings.
A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
Next, click on the button labeled Reboot Server. After rebooting the NetWayG will be set in the DHCP mode. The IP address will be assigned by the router when the NetWayG is connected to the network.
It is recommended to have the assigned IP Address reserved to ensure continued access (see the network administrator).
B. Subnet Mask: When operating in DHCP, the router will assign the subnet mask values.
C. Gateway: Enter the TCP/IP gateway of the network access point (router) being used.
D. HTTP Port: Enter the HTTP port number assigned to the NetWayG module by the network administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.

Secure Network Setup (HTTPS):
In order to set up HTTPS for a Secure Network Connection, a Valid Certificate and Key must be used. Certificates and Keys should be in a “.PEM” format. Self Certifications should only be used for testing purposes as no actual authentication is being performed. In a Self-Certified mode, the connection will still state that it is unsecure. How to upload  Certificate and Key to setup HTTPS:

  1.  Open Tab Labeled “Security”
  2. Select Tab Labeled “Email/SSL”
  3. Scroll to the bottom under “SSL Settings”
  4. Click “Select Certificate”
  5. Browse and select a valid Certificate to upload from the server
  6. Click “Select Key”
  7. Browse and select a valid Key to upload from the server
  8. Click “Submit Files”

Once the Certificate and Key are uploaded successfully you can proceed with setting up
HTTPS in Network Settings.
A. HTTPS Port: Enter the HTTPS port number assigned to the NetWayG module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443.
Being encrypted and more secure, HTTPS is highly recommended for remote access.
B. Click the button labeled Submit Network Settings.
A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.

Mounting Options:

Rack Mount Installation

  1. Remove and discard factory-installed screws from both sides of the rack chassis (Fig. 5a).
  2. Install mounting brackets (A) on the left and right side of the rack chassis using the four (4) flat head screws (B) (included) (Fig. 5b).
  3. Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 5c).

Altronix NetWay8G PoE Managed Midspan Solution - fig4

Wall Mount Installation

  1. Install mounting brackets (A) on the left and right side of the rack chassis using four (4) flat head screws (B) (included) (Fig. 6a).
  2. Place the unit at the desired location and secure it with #6 size screws or larger (not included) (Fig. 6b).
    Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.

Altronix NetWay8G PoE Managed Midspan Solution - fig5

Shelf Installation

  1. Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 7).
  2. Place the unit in the desired location.

Altronix NetWay8G PoE Managed Midspan Solution -
fig6Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IINetWayG H23U

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals