SCHONSTEDT GA-92XTd Magnetic Locator Instruction Manual
- June 4, 2024
- SCHONSTEDT
Table of Contents
- SECTION I: INTRODUCTION
- SECTION II: OPERATING CONTROLS
- SECTION III: VISUAL AND AUDIBLE INDICATORS
- SECTION IV: CONNECTORS AND ACCESSORIES
- SECTION V: BATTERY REPLACEMENT
- SECTION VI: OPERATING RECOMMENDATIONS AND APPLICATION NOTES
- Search Procedure
- Basic Signal Patterns
- Strongly Magnetized Markers
- Correct Stake Orientation
- Locating Manholes, Septic Tanks and Well Casings
- Locating and Tracing Barbed Wire
- Searching Areas along a Chain Link Fence
- Locating Valve Boxes
- Locating Cast-Iron Pipes
- Locating Steel Drums
- Locating Ordnance and Weapons
- Other Notes
- SECTION VII: SPECIFICATIONS
- SECTION VIII: TECHNICAL SUPPORT
- SECTION IX: WARRANTY / SERVICE INFORMATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SCHONSTEDT GA-92XTd Magnetic Locator
Seattle 425-771-7776
Tacoma 253-922-6087
Portland 503-641-3388
Salt Lake City 801-878-9763
Las Vegas 702-586-1152
St. George 702-586-1152
Boise 208-369-4388
Schonstedt Instrument Company
100 Edmond Road, Kearneysville, WV 25430
P: (800) 999 – 8280 www.schonstedt.com |
schonstedt.inf@spx.com
SECTION I: INTRODUCTION
The GA-92XTd magnetic locator detects the magnetic field of ferromagnetic objects. It responds to the difference in the magnetic field between two sensors that are spaced approximately 9.5 inches apart. This difference is referred to as the “signal strength” throughout this manual and is represented in the instrument by an audio tone, the display of a bar graph, and a numeric indication. In addition, the polarity of the signal strength is shown as a + or sign on the display, and determines the side (right or left) on which the bar graph is displayed. Although most objects can be located using the audio indication alone, simultaneous use of the audio and visual responses will provide additional information to help you pinpoint a target and determine its orientation.
Figure 1 illustrates an application of the GA-92XTd locator in which it is used to detect an iron marker used for property line identification. As shown, the magnetic field of the iron marker is stronger at sensor A than it is at sensor B. This creates a signal strength that is larger than zero (which would occur when the field strength is the same at both sensors).
The audio response of the GA-92XTd is designed so that the frequency of the audio tone increases as the detected signal strength increases. As a result, the frequency of the audio output is higher than the idling frequency (~ 30 Hz) that exists when the signal strength is approximately zero. The larger signal strength also causes the bar graph display to peak in either the positive or the negative direction.
The GA-92XTd unit can be operated either in the open or closed position and any position in between (see Figure 2).
NOTE: In the closed position using non-lithium batteries, a slight signal may be detected in the high gain settings even if no ferrous material is present. This can be avoided by 1) decreasing the gain, 2) operating the unit in the extended position or 3) using a lithium battery.
The GA-92XTd has an internal detent mechanism to keep the unit in either the fully extended (open) or fully retracted (closed) position. To extend the unit, grasp the looped end of the locator and pull until the shaft locks into place. To return the unit to the closed position, push the looped end back into the shaft. The unit will lock into place.
SECTION II: OPERATING CONTROLS
ON / Volume : To turn the unit on, push this button. Upon turn on, the volume defaults to HIGH. Pushing the button a second time changes the volume to MEDIUM. Pushing the button a third time MUTES the volume. Additional pushes of this button cycle the volume through HIGHMEDIUM-MUTE.
OFF: To turn the unit off, push this button.
GAIN : The sensitivity of the unit can be increased (to detect smaller objects at greater depths) or decreased (to detect larger objects at smaller depths) by adjusting the gain up or down pushing the UP or DOWN arrow buttons.
SECTION III: VISUAL AND AUDIBLE INDICATORS
Gain Level Indicator: The gain range is indicated by a 4-segment LCD as
shown in Figure 4: L (Low), M (Medium), H (High) and XH (Extra High). Upon
turn on, the gain defaults to M (Medium). Each press of the UP or DOWN arrow
buttons will cause the gain level indicator to change accordingly.
Battery Level Indicator: The battery level is indicated by a 4-segment
LCD indicator, as shown in Figure 5. When all four segments are black, the
voltage level is between 100% and 75%. As the voltage decreases, the number of
black segments decreases. Battery life varies with usage and the ambient
temperature. Cold temperatures reduce battery life. Low temperatures may
result in only two or three segments being black. This could be temporary, and
all segments will change to black as the temperature increases.
Signal Strength and Polarity Indicator: The signal strength, defined as the difference (or delta Δ) between the magnetic field detected at the top and bottom sensors, is shown as a numerical indication in mG (milligauss) units, is preceded by the polarity of the signal (+ or -), and is followed by the Δ symbol (to emphasize that it represents a “difference” between the two ends of the sensor array).
In addition, the signal strength is shown in a semi-circular bar graph, with
more bars indicating a stronger signal. Depending on polarity, the bar graph
will switch to the + (right) or (left) side. The signal strength is also
indicated by the frequency of the audio signal; a higher audio frequency
indicates a stronger signal.
Figure 6 shows the various visual indications of signal strength and polarity.
SECTION IV: CONNECTORS AND ACCESSORIES
Headphone Jack: The headphone jack is located on the side of the unit
near the face of the locator. Headphones are optional and may be purchased
from Schonstedt as an accessory. The headphone jack is monaural. Standard
stereo headphones may be used, but they will produce sound in only one ear.
When the headphones are plugged in, the speaker sound will be muted, but the
ON/Volume button still controls the volume of the headphones.
Headphone Jack Plug: A Headphone Jack Plug has been included with this
product. It is recommended that the plug remain inserted into the jack any
time that headphones are not in use. This aids in making the instrument more
water-resistant.
SECTION V: BATTERY REPLACEMENT
The GA-92XTd is powered by one 9-volt battery. The battery is located in the
handle of the instrument and can be accessed by turning the screw
counterclockwise. To remove the battery, tilt the unit so that the handle is
pointing down, and the battery will slide out. When replacing the battery,
look at the outside of the battery door for the proper battery orientation. As
a safety measure, the unit will not turn on if the battery is not inserted
correctly. You should never have to force the battery door closed. If the
battery does not seem to be going in all the way, remove the battery, reverse
its orientation and then replace it.
SECTION VI: OPERATING RECOMMENDATIONS AND APPLICATION NOTES
Search Procedure
Turn the instrument ON. The gain defaults to Medium (M). Grasp the locator, as illustrated in Figure 10.
Since the upper sensor is located near the handle of the instrument (especially if it is being used in the collapsed position), wristwatches may produce unwanted changes in the audio signal and in the meter indication. Therefore, watches should be removed. Keep the locator away from your shoes as they may contain magnetic material.
To obtain a maximum coverage area, sweep the locator from side to side. When the locator comes within range of an iron object, the signal strength will peak, the frequency of the audio signal will peak, the bar graph will expand in the positive or negative direction, and the digital readout will peak. This is shown in Figure 11.
NOTE: The number of bars shown in the bar graph, the number displayed in the digital readout, and the frequency of the audio signal will all depend on the signal strength, which is affected by the type of iron object detected, its orientation, and the gain setting.
Basic Signal Patterns
When the GA-92XTd is positioned directly over a vertical target, the signal strength will peak (audio signal, digital readout, and bar graph) at either a positive or negative polarity.
The audio signal, digital readout, and bar graph indications also peak over each end of a horizontal target. One end is positive, the other is negative. This will help you to distinguish between two vertical pipes or one horizontal pipe. Usually two vertical pipes buried in close proximity will produce bar graph indications with the same polarity.
After you have detected the presence of a target, hold the locator vertically and slowly move it back and forth in an “X” pattern while listening to the audio response and observing the bar graph indicator. For a given gain setting, the number of bars will be greatest when the locator is directly over a vertical target or the ends of a horizontal target. The “X” pattern, as shown in Figure 13, is ideal for pinpointing small objects. A 1-1/4 inch PK nail buried up to 10 inches can be located precisely using this technique.
If you are looking for a corner marker and detect two or three signals in the same general vicinity, raise the locator several inches above the ground or decrease the gain setting. Any signal that disappears when the locator is held higher or when the gain is decreased is likely coming from a smaller target. The signal from a rusty bolt or other small item (see Figure 14) is much weaker than the signal from a larger target, such as an 18-inch length of 3/4 inch rebar which can be located at depths up to 8 feet.
Strongly Magnetized Markers
A strongly magnetized marker that is at or near the surface will provide a weaker indication on both sides of the marker, and that could be mistaken for the marker.
The heavy line in Figure 15 represents the increase and decrease in the audio and bar graph indications as you move the locator over a marker. Between points A and B, the signals increase slightly and then decrease. Just beyond B, the signals increase rapidly, peak directly over the marker and then decrease at point C. From C to D, the signals increase and decrease again. Therefore, if you do not move the locator completely across the marker, you might assume that the weaker indication on either side of the marker is its location. The two weaker indications occur because the locator is extremely sensitive to the magnetic field components that are parallel to its long axis. At points B and C, the field is perpendicular to the locator; therefore, no significant audio or bar graph indications are produced at these points.
Correct Stake Orientation
When placing stakes, correct orientation is important.
For checking purposes, the orientation of the pin relative to the locator is
shown in Figure 16.
Check the pin with one orientation. Then rotate the pin 180°. The orientation
that gives the largest reading is the one that should be used. This reading
should be positive in the Northern Hemisphere and negative in the Southern
Hemisphere.
An iron pin has two types of magnetization. One is the magnetization induced by the Earth’s magnetic field. The induced magnetization is always downward in the Northern Magnetic Hemisphere and produces a positive output no matter which end of the stake is driven into the ground. The other type of field is the permanent magnetization that is fixed to the pin. For maximum detection, the stake should be driven into the ground such that the permanent magnetization is in the same direction as the induced magnetization.
Locating Manholes, Septic Tanks and Well Casings
The magnetic field is strongest at the edge of a shallow manhole cover. You can easily trace the edges of covers near the surface. Locating depths for manhole covers range up to 9 feet.
The great length of a well casing provides a strong field at the surface that makes it easy to locate casings buried up to 16 feet deep.
The GA-92XTd can also be used to precisely locate the metal handles or reinforcing bars on septic tank covers at depths of up to 4 feet.
Locating and Tracing Barbed Wire
You can often trace barbed wire (from old fence lines) buried just beneath the surface. Even if the wire is only a trail of rust, it can still be detected near the surface. Tip the locator a little lower than usual – but not parallel with the ground.
Examine trees for bench marks and bits of embedded barbed wire. Hold the locator parallel with the direction of the wire.
Searching Areas along a Chain Link Fence
Searching in the vicinity of a chain link fence requires a reduced sensitivity setting and some control over the orientation of the locator. As illustrated in Figure 22, position the locator horizontally with its long axis perpendicular to the fence. This insures that the upper sensor is kept away from the fence.
Perform the search by slowly moving the locator forward along the fence while also moving it to the right and to the left. As you move forward, this technique allows you to search an area several feet wide. Listen for an abrupt drop in the signal (as shown by the null in Figure 23) that will occur when the lower sensor, located 1-1/2 inches from the end of the locator, is directly over the stake. Any variation in the position of the locator will produce an abrupt rise in the frequency of the signal.
Locating Valve Boxes
Both the valve and its casing, when iron, provide strong magnetic fields that make them easy to locate. Plastic enclosures containing magnets (which are typically used with non-ferrous valve boxes) are easily located at depths of up to 9 feet.
Locating Cast-Iron Pipes
As illustrated in Figure 25, cast-iron pipes produce the strongest magnetic signals at their joints.
After an initial sweep search identifies the general direction of the pipe, the steel pipe joints or transition points can be more accurately traced by the following procedure:
- Set the Sensitivity control to maximum (XH indication).
- Hold the locator vertically approximately 1 to 1-1/2 feet above the surface.
- Walk without turning or tilting the locator.
- Mark the locations where the maximum signal levels occur.
- Return to an area of maximum signal strength and hold the locator several inches above the surface. The sensitivity will probably have to be reduced during this second pass. Four-inch pipes can be located at depths up to 9 feet.
Locating Steel Drums
As shown in Figure 26, the GA-92XTd’s signal pattern will vary depending on the vertical or horizontal orientation of the drum and how deep it is buried.
A fifty-five gallon drum can be located at depths ranging from 4 feet to 9 feeet.
Locating Ordnance and Weapons
The versatile, lightweight, cost-effective GA-92XTd is also designed to aid EOD technicians and law enforcement officers during area search operations.
Other Notes
- A burbling sound indicates the presence of an energized power line. This will not influence the meter indication unless it is associated with a magnetic structure.
- The instrument will not respond to non-ferrous metals, such as gold, silver, copper, brass and aluminum.
| This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (l) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
---|---
| Application of Council Directive(s): 2004/ 108/EC
Standard(s) to which Conformity is Declared: EN 6 I 000-6-1:2001 ,
EN61000-4-2, EN6 l 000-4-3, EN 61000-6-3:2004, EN55022:1998 with Amendment Al
:2000 (CISPR-22)
SECTION VII: SPECIFICATIONS
(Specifications subject to change without notice)
Output:| Audio: Signal increases or decreases in frequency with signal
strength (gradient field intensity). Audio frequency range: 30 to 4000 Hz.
---|---
Visual: Expanding bar graph and +/- signs indicates polarity and signal
strength. Digital readout shows gradient field intensity expressed in
milligauss (mG). Range: 0 to 500 mG
Battery Indicator| 4-segment LCD
Gain| 4-Level LCD: Low (L), Medium (M), High (H), Extra High (XH)
Volume| 3 Levels: Muted, Medium and High
Input Power| One 9V battery
Battery Life| 24 Hours (intermittent usage)
Operating Temperature| -13° F to 140° F (-25° C to 60° C)
Water and Dust Resistance| Rated IP54, when operated with earphone jack plug
(provided)
Overall Length| Open: 26” (66 cm), Closed: 15.5” (39 cm)
Nominal Sensor Spacing| 9.5” (24 cm)
Weight| 2.4 lb. (1.1 Kg)
Construction Material| High impact ABS
SECTION VIII: TECHNICAL SUPPORT
Schonstedt offers technical support and sales support. For any reason regarding usage and application please contact our technical support team at888-367-7014.
SECTION IX: WARRANTY / SERVICE INFORMATION
Limited Warranty:
Schonstedt Instrument Company (Schonstedt) warrants each product of its
manufacture to be free from defects in material and workmanship subject to the
following terms and conditions.
The warranty is effective for 7 years* after the shipment by Schonstedt to the
original purchaser. Please complete the warranty registration card and send
back to Schonstedt Instrument Company.
Schonstedt’s obligation under the warranty is limited to servicing or adjusting any product returned to the factory for this purpose and to replacing any defective part thereof. Such product must be returned by the original purchaser, transportation charges prepaid, with a description of the defect in writing. If the fault has been caused by misuse or abnormal conditions of operation, repairs will be billed. Specifically, this warranty does not cover product that has been subject to inundation by fire, water or other liquid intrusion, or units that have been damaged or compromised due to repair, alteration or modification by anyone other than an authorized repair representative. Prior to a repair being performed by Schonstedt, a cost estimate will be submitted and no work will be completed until authorized by the customer. Batteries are specifically excluded under the warranty and should be addressed to the manufacturer of batteries in question.
Schonstedt shall not be liable for any injury to persons or property or for any other special or consequential damages sustained or expenses incurred by reason of the use of any Schonstedt product.
- For Military & EOD applications, the warranty is 1 year.
Service Information:
If your locator needs service, please return it to the factory along with the following information: Name, Address, Telephone, Fax number, Where Purchased, Date, and Description of Trouble(s). An estimate will be provided prior to service work being done.
For Service or Repair
Please ship locator (in its case) to:
Schonstedt Instrument Company 100 Edmond Road Kearneysville, WV 25430
Manufactured By
Schonstedt Instrument Company 100 Edmond Road, Kearneysville, WV 25430
Phone: 800-999-8280
Fax 304-725-1095
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>