National Luna Legacy SMART Portable Refrigerator User Manual
- June 9, 2024
- National Luna
Table of Contents
National Luna Legacy SMART Portable Refrigerator
Safety information
Failure to follow these instructions may result in damage to the appliance or injury to yourself and others.
-
Suitable for camping use.
-
This product is not designed for marine applications.
-
Do not expose the appliance to water, rain, corrosive liquids or strong chemicals.
-
Do not operate near explosive or flammable gases or materials.
-
Do not operate or store in high-temperature environments.
-
Always operate this product on a stable surface.
-
Do not invert the refrigerator during operation or storage.
-
Do not store explosive or hazardous materials inside the fridge.
-
Do not use in restricted spaces or areas with limited ventilation.
-
Do not block or cover the ventilation holes.
-
Do not push objects of any kind into ventilation slots or holes.
-
Do not use the appliance for purposes other than indicated in this manual.
-
This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
-
Children being supervised not to play with the appliance.
-
Do not attempt to service this product yourself. Refer to qualified technician.
-
Ensure electrical supply meets the input specifications listed on the appliance rear panel.
-
The appliance may be connected to more than one source of energy.
-
WARNING: When positioning the appliance, ensure the supply cord is not trapped or damaged.
-
WARNING: Do not locate multiple portable socket outlets or portable power supplies at the rear of the appliance.
-
Do not use damaged or modified power cables.
-
Do not handle electrical cables with wet hands.
-
Do not fill the interior with liquid or ice without suitable water-tight containers.
-
Store foods in original packaging or suitable containers.
-
Clean interior surfaces that may be in contact with food regularly.
This appliance is intended to be used in household and similar applications such as : -
Staff kitchen areas in shops, offices and other working environments.
-
Farm houses and by clients in hotels, motels and other residential-type environments.
-
Bed and breakfast type environments.
-
Catering and similar non-retail applications.
When used in a mobile environment :
- Secure the appliance with straps or a mounting fixture designed for this purpose.
- Ensure cables are not under tension and are protected from areas of movement.
- Ensure cables are not exposed to sharp edges or risk of crushing.
- Use the appropriate cable size and type for dedicated wiring circuits.
Introduction
Thank you for your purchase of a National Luna Legacy Smart refrigerator.
This product comes from a wide family of high-efficiency, high-quality
refrigerators designed specifically for mobile applications or remote
installations such as off-road vehicles, caravans, trailers and solar
applications.
The SMART series inherits the rugged design and superior cooling performance
of the LEGACY series and now also offers the ability to monitor and control
the fridge operations wirelessly using the new NL CONNECT mobile application.
All models offer dual USB charge ports that support multiple high-speed
charging protocols for mobile devices.
For compatibility with space-constrained applications, the NL35, NL45, NL50
and NL52 offer a main door that can be re-configured to open in a different
orientation. In addition, all models offer a control panel that can be shifted
between the front and side.
Every model can be powered directly from a 12V or 24V battery as well as 100V
to 240V AC supply. Standard features include : LED interior lights, folding
carry handles, bottle-openers, low-battery protection, automatic speed control
and independent cooling on Double-Door and Dual models.
Models covered in this manual
Single compartment : NL35, NL40, NL45, NL52, NL55, NL65, NL80, NL125
Dual compartment : NL50, NL60, NL70, NL90
Double Door : NL72, NL110
Side-mount (specially-modified versions of) : NL70, NL72, NL80, NL90, NL110,
NL125
Symbols and terms used in this document
Some symbols are used in this manual or on the product.
These symbols have the following meanings :
Ventilation clearance
- Slots and openings in the body are provided for ventilation; to ensure reliable operation and to protect against overheating, these opening should never be blocked or covered.
- A minimum clearance of 60mm is recommended on the back, side and front of the fridge for ventilation.
- This product should never be placed in a built-in installation with limited airflow unless adequate ventilation is provided.
Closed compartments should provide for cool air intake and warm air exhaust.
Guide to electrical wiring
This appliance is optimised for mobile use. Standard 12V accessory sockets
used in many motor vehicles can be used but may result in unreliable operation
due to thin wiring and high voltage loss. For long-term reliable operation in
a motor vehicle or other mobile application, it is recommended to install
dedicated 12V / 24V wiring and suitable DC-rated connectors.
A minimum cable gauge of 4mm2 (12 AWG) should be used between the fridge and power source (battery). For safety, a 15A fuse should be installed close to the battery on the positive cable.
When connecting the AC supply, make sure the cable plug is appropriate for the
region or country of use and the cable is not damaged. Verify the AC supply
voltage is within the fridge operating voltage range. Do not place AC plug
adaptors or power supplies on or behind the fridge.
Protect all cables from potential damage, particularly in applications where
the fridge or cables are likely to move, such as in sliding or drawer systems.
Protect the cables from sharp edges and areas that may be exposed to high
heat.
- DO NOT use a modified or damaged power cable. Doing so may result in serious injury or damage to the appliance.
- If dedicated wiring is installed to supply the fridge, a 15A fuse should be fitted on the positive cable near to the battery.
- Before installation of any additional wiring, check that this action will not void any vehicle warranty or service agreement.
External features
Single compartment
Single Compartment models : NL40, NL52, NL55, NL65, NL80, NL125
Single Compartment models : NL35, NL45
Dual Compartment and Double Door
Dual Compartment models : NL50, NL60, NL70, NL90
Double Door models: NL72, NL110
Side-mount
Side-mount models are specially-modified versions of single or dual- compartment models.
This modification can only be applied to NL70, NL72, NL80, NL90, NL110 and NL125 models.
The control panel and power inputs have been shifted to better fit specific applications where there is limited access to these features, such as trailer sliding systems.
The AC and DC power inputs are recessed on side-mount models.
Side-mount models do not have USB charge ports.
Latches and Handles
Depending on the model, the fridge will have one or two door latches which are
used to keep the main door closed securely.
Stainless steel latches provide a locking hole that can be used with locks or
tamper-evident seals.
The plastic latches are only on the NL35 and NL45 models.
Bottle-opener strip
Each door handle has an integrated bottle-opener strip.
This can be used to remove standard bottle caps.
Hook the bottle cap on the metal strip and pull the bottle upwards against the
handle to detach the bottle cap.
USB charge ports
There are two independent USB-charging ports available on the side.
Each port is capable of fast-charging up to 24W maximum power and will be
active when the fridge is connected to DC or AC power sources.
USB charge ports remain active if the fridge is in standby mode.
USB charge ports are not affected by low-battery protection.
Securing fridge in a mobile application
-
Using a base plate (optional accessory)
It is recommended to use a base-locking plate
(available separately) to secure a fridge in a mobile application.
The base plate is usually bolted to the vehicle load area or onto a sliding mechanism and allows the fridge to be secured without additional straps.
The fridge slide-locks onto the base-plate and is secured in place with locking pins. -
Using straps
Carry handles each feature a tie-down slot that can be used with standard 25mm straps.
These can be used to secure the fridge to tie-down points.
Take care not to over-tighten straps as this can cause damage to the handles or fridge body.
Only use the provided tie-down slot. Do not strap to the folding hand-hold.
Changing door configuration – NL50 and NL52 models
NL50 and NL52 models have the ability to shift the door opening direction from
the front to the side. This can be useful for applications with limited
access.
-
Prepare new handle and latch position
Remove the screws from the new handle and latch location. -
Remove the door handle & latch
Remove the door handle and latch from their current location. The handle includes a metal latch hook and bottle-opener strip. Take note of the order they are removed. -
Attach handle & latch
Using the same screws, attach the handle and latch to the new location.
Note that the metal door hook fits underneath the plastic handle.
Align the lower latch to the door hook and tighten the screws. -
Remove hinge covers & hinges
Prepare the new hinge locations by removing the upper and lower covers.
Remove the hinges from their current location. -
Attach hinges
Attach the loose hinges to their new locations using the same screws.
It is best to attach the lower half of the hinge to the fridge body first.
Before tightening the screws, check the tension on the lid seal. (refer to page 29 for details) -
Cover unused locations
Use the hinge covers removed earlier to cover the unused hinge locations.
Insert the remaining screws from the door handle into the unused holes.
NL35 and NL45 models
The unique door design and updated door latches of the NL35 and NL45 models allows the lid to be configured to open from the front, end or in the reverse direction to better suit a particular application.
The below procedure shows changing from the default front-opening
configuration to the end-opening
configuration.
When changing between front and end-opening, only one latch needs to be moved.
- Remove the upper and lower hinge covers from the unused hinge positions.
- Remove both hinges from their current locations.
- Attach the hinges to their alternate locations and adjust door alignment to the body.
- Remove the upper and lower door latches. In most cases, only one latch needs to move.
- Attach the upper and lower door latch to the alternate position. Adjust if necessary.
- Remove the door handle with bottle-opener strip from its current location.
- Re-attach the door handle to its alternate location.
- Cover the unused hinge locations with the upper and lower hinge covers.
- Secure the remaining screws in the door handles’ previous location.
After re-configuring the door, the seal tension should be adjusted.
Refer to page 29 for this procedure.
Changing control panel position
The control panel can be moved from its default front-facing position to the alternate end-facing position.
This configuration is useful for applications where the front is not easily accessible, such as in drawer systems.
CAUTION
Moving the control panel can be technically challenging and damage can occur
if this procedure is not undertaken carefully. This procedure should be
performed in an environment suitable for electronics with appropriate anti-
static precautions observed.
Ensure all power sources are disconnected before starting this procedure.
- Remove the 4 screws and locking washers holding the control panel.
- Allow the control panel to drop downwards. It can then be pulled forward.
- Open the connector locking clips and detach the cable from the control panel.
- Remove the 4 screws and locking washers holding the side cover panel.
- The cover panel can be tilted and removed from the side opening. Set it aside.
- Pass the cable detached earlier through the side opening and attach to the control panel.
- Install the control panel into the side opening, passing the top edge in first.
- Align the control panel with the opening and insert the screws and lock washers.
- The loose cover plate can be installed into the front opening.
- Hold the cover plate in place and install the remaining screws with lock washers.
Connecting power
DC supply input
For battery-powered applications, connect the supplied DC cable (or approved
replacement) into the DC input socket and ensure it is properly inserted.
Connect the other end to the DC power source.
Ensure polarity is correct before connecting the DC supply. Incorrect polarity may result in permanent damage.
AC supply input
For AC power sources, connect the supplied AC cable (or approved IEC cable) to
the AC input socket and ensure it is properly inserted.
Connect the other end to the AC supply.
AC and DC supply can be connected simultaneously. The fridge will switch between the available power sources automatically. Priority is given to AC power.
User interface
Depending on the fridge model, the control panel will provide either a Single
or Dual temperature interface.
Both types provide Battery Protection and Speed control settings as well as
Fault and Run status indicators.
Start display sequence
When power is applied to the fridge, the control panel will display a start
sequence.
During this initialization period, all digits will be turned on, followed by a
version number.
This identifies which program version the fridge is running.
The sequence ends with a display of the currently-measured temperature. The fridge is now ready for operation.
Single compartment models
Dual compartment models will show the configured model on the left display and the program version on the right display.
-
Display test.
-
Configured model and program version.
(NL50 shown in this example) -
Current temperatures are shown
If the configured model number does not match the physical model of the fridge there can be unexpected behavior. Contact technical support for instructions on how to reset the model configuration.
Battery protection
Battery protection is used to prevent excessive discharge and potential damage
to a source battery. The choice of setting will depend on the specific
application.
Press and hold the battery button to cycle through available options.
- HIGH is recommended when powering the fridge from a vehicle main battery. This provides the highest protection level.
- MED is recommended for most applications where a deep-cycle auxiliary battery is used to power the fridge.
- LOW can be used to prioritize fridge run-time over battery discharge.
12V | STOP | RESTART |
---|---|---|
HIGH | 11.5V | 12.5V |
MED | 10.5V | 11.8V |
LOW | 9.5V | 10.9V |
12V | STOP | RESTART |
--- | --- | --- |
HIGH | 11.5V | 12.5V |
MED | 10.5V | 11.8V |
LOW | 9.5V | 10.9V |
Speed control
Under normal conditions, the fridge will automatically balance cooling
performance and efficiency.
This is preferred for most applications.
TURBO mode will increase cooling performance but at the expense of increased energy consumption.
The TURBO mode can be toggled by holding the TURBO button for 3 seconds.
TURBO mode may increase power consumption.
Standby mode
The fridge can be put into a standby mode by holding the UP button for 3
seconds.
(right compartment control on Dual models)
Press and hold the UP button again to exit standby and return to normal
operation.
The ON/OFF state is saved if power is removed. This setting is restored when
power is applied.
When in standby mode, the fridge interior light and USB ports will remain operational.
Choosing the temperature display units (°C / °F)
The temperature display units can be toggled between °C / °F by briefly
pressing both UP and DOWN buttons together.
The display will then change to the selected units.
On Dual models, press the two buttons on the Right Compartment.
Setting the desired temperature
-
The compartment temperature can be adjusted by entering the SET mode on the respective compartment :
Hold the DOWN button until the display begins to flash.
The procedure is the same for both controls on
Dual-compartment models. -
When the display is flashing, press UP or DOWN to increase or decrease the compartment temperature.
When the desired value is reached, release all buttons.
After 10 seconds, the display will stop flashing and the new setting will take effect.
The display will then return to showing the current temperature.
Disabling a compartment – dual models only
On Dual models, it is possible to independently turn off the left or right
compartment.
This can be used to reduce power consumption if only one compartment is
needed.
To turn off a compartment, enter the settings mode.
Increase the temperature setting until “OFF” is displayed. Release the
buttons.
To re-activate the compartment, enter set mode and set any desired
temperature.
RUN indicator
The RUN status indicator will show when the fridge compressor is running. Dual compartment models will have two RUN indicators which will show which compartment is being cooled.
- OFF – The compartment is not cooling.
- ON – The compressor is running and the compartment is being cooled.
Flashing (1/2 second on, 1/2 second off) –
Start delay before compressor runs.
Flashing (1 second on, 1 second off) –
Compressor is slowing down before stopping.
Fault diagnostics
There are several parameters being monitored by the fridge during
operation.
If a fault is detected, it will be identified by flashing the Fault-ID indicator
between 1 and 6 times within a 4-second period. The number of flashes will
indicate which fault has been detected.
1 flash
| Low voltage – The DC supply voltage is lower than the chosen battery
protection level. Check the battery and all wiring from the battery. This can
also occur with an AC power supply fault.
---|---
2 flash
| Fan over-current – This can occur if the ventilation fan is blocked or damaged. Check the fan intake for signs of excess dust or debris. This can also occur if the fan has failed.
3 flash
| Motor start error – The compressor is unable to start. This can occur in extreme environments with high temperatures and heavy loads. This error can be temporary and may clear automatically.
4 flash
| Minimum speed error – The compressor is unable to maintain a minimum speed. This can be an electronics failure or over- pressurised system.
5 flash
| Over-temperature – The electronic driver is too hot and has shut down. This can occur if the ventilation intake is blocked or the fan is damaged.
6 flash
| Driver failure – The electronic driver has suffered a failure. This may be permanent damage and may require replacement.
In addition to the 6 flash codes, if a fault is detected on the internal
temperature sensors, a “PrF” message is displayed. This indicates a “Probe
Failure” and that the sensor may need to be replaced.
Dual models have two sensors. A “PrF” message may be displayed on either the
left or right display – this will show which of
the two sensors is problematic.
NL CONNECT Mobile application
Legacy SMART fridges include Bluetooth® wireless technology that allows the
status and settings to be monitored by a connected mobile device.
The NL CONNECT application allows the user to observe the fridge status,
adjust settings and be notified of fault conditions.
The NL CONNECT application is available for iOS and Android devices and can be
downloaded from the respective APP stores.
Scan the QR code below or type the web address into your mobile device to
access download links.
www.nationalluna.com/nlconnect
NL CONNECT requires that Bluetooth® and location services are enabled on the mobile device.
Supports :
iOS version 13 or later Android version 6 or later
Scanning and connecting to devices
When opening the CONNECT APP, a scan for nearby devices will start
automatically.
A scan can also be started manually by tapping SCAN.
Nearby compatible devices will be listed with their default names.
If a custom name was set for a previously-connected device, this name will be
displayed instead.
The scan process must complete or be cancelled before connecting to a device.
Tap a listed device to establish a connection with it.
When connecting with a new device, a prompt to enter the PIN will be
displayed.
Enter the fridge serial number as displayed on the back of the fridge and then
press ENTER.
see page 35 for details about where to locate the serial number.
If the PIN is correct, a connection to the fridge will be established.
If a device has been previously connected, it will be remembered and entering a PIN will not be required.
Removing remembered devices
Previously-connected devices will be remembered by the APP and listed with a
trash icon in the scan list.
In order to forget a device, tap the trash icon and then OK on the confirmation
prompt.
This will forget the device PIN and any custom name that may have been set for it.
CONNECT Dashboards
When a connection is established, a dashboard relevant to the connected device will be shown. This dashboard will show the device name, temperatures, setting options and the current status.
Setting desired temperatures
Temperature dials will show the current temperature and whether the
compartment is cooling or idle.
To adjust a temperature setting, tap on the respective temperature dial. The
current setting is displayed.
- The status bar will now show controls to increase or decrease the setting. Press + to increase temperature. Press – to decrease temperature.
- Press OK to complete the setting.
Change battery protection level
To adjust the battery protection level, press the PROTECTION dial. Each press will cycle between the available options.
11.5V (High) – This is best when the fridge is powered by a vehicle main battery and the least discharge level is preferred.
10.5V (Med) – Best for most applications where the fridge is powered by a deep-cycle auxiliary battery.
9.5V (Low) – This can be used if priority is to have longer run time at the expense of deep battery discharge.
It can also be used to temporarily compensate for some installation faults.
A LOW battery protection setting may result in excessive battery discharge.
Changing speed mode
The speed control will toggle between the AUTO mode, where the fridge will automatically balance cooling performance, and TURBO mode where maximum cooling performance is desired at the expense of increased power consumption.
AUTO – Best for most applications. The fridge will manage compressor speed automatically.
TURBO – Over-ride the speed control and run at maximum speed. This increases cooling performance.
TURBO mode can increase power consumption.
Changing temperature units (°C / °F)
To toggle between °C and °F, first access the settings page by pressing the
gear icon.
On the settings page, select the preferred temperature units.
There may be a short delay for the fridge display to update.
Press back to return to the dashboard.
Status and Fault indication
The status bar shows the current fridge status at any moment. It will indicate
if the fridge is running, is idle or in a startup delay.
Any detected faults will also be indicated on the Status bar.
The fridge has reached temperature and is idle.
The fridge is preparing to start the compressor and cool a compartment.
The compressor is running and a compartment is being cooled.
The compressor is slowing down before stopping.
A fault has been detected.
Press the up arrow for more information about the fault.
Setting a custom name (nickname)
A custom name can be set for a connected fridge. This name is saved in the APP
memory and is linked to the fridge unique hardware number.
The configured name will be displayed on the dashboard and in the scan list
when scanning for nearby devices.
To set a custom name, go to the settings page.
Tap the text block with the current device name.
A keyboard will appear and you can type a new name.
Press OK or Enter when done.
Connect automatically option
If this option is set, when the APP is opened, it will attempt to connect
automatically to the last-connected device if it is within range.
You will not need to select the device from the scan list.
Keep screen on option
This option will prevent the screen of the mobile device from turning off
while the APP is open.
Note – this will increase battery use on the mobile device.
Defrosting
It is normal for ice to accumulate on the cooling surfaces of a freezer. This
will be more significant in humid environments. Increased ice build-up will
reduce cooling performance and should be removed periodically.
- Before defrosting, remove any contents of the fridge or freezer compartments.
- Disconnect all power cables from the fridge and open the main door.
- Allow any ice or frost to melt.
- Use a soft cloth to remove melting ice and water.
- Do not use sharp objects to scrape ice from the cooling surfaces.
It is best to dry the interior before turning on the fridge.
Care and cleaning
Use a soft cloth with mild detergent if necessary to clean the exterior of
your fridge.
Make sure surfaces are dry before storage.
- The interior should be cleaned regularly to prevent bacteria and odours from forming.
- Use a soft cloth with mild detergent or anti-bacterial soap, do not use abrasive or strong chemicals.
- Do not use ammonia-based cleaning agents or strong acids.
- Do not use sharp tools to remove ice on the cooling surfaces.
- The ventilation intake on the rear of the fridge may accumulate dust or debris over time. Check the vents regularly and blow out any dust, remove any loose debris.
A blocked air intake can result in poor cooling performance and increased power consumption.
Storage when not in use
When your fridge is not in use, it is best to clean the interior and exterior
prior to storage. Turn off the fridge and remove power cables.
It is recommended to keep the door open to allow air to circulate inside the
fridge.
This will help keep the interior dry and prevent odours.
A door latch can be used to keep a door open as indicated below
TIP – Place baking soda in an open container and position inside the fridge. This will help to absorb odours.
Adjusting door tension
Over time, the door seal may compress or deform.
This is normal and it may be necessary to adjust the door tension.
Adjustable door hinges
- Unclip the door latches.
- Loosen the 3 lower screws on each door hinge.
- Apply light, even pressure on the back edge of the door. The door seal should be lightly compressed.
- Tighten the 3 screws on each hinge.
- Close the door latches and check their tension.
They should not be loose or overly tight.
Adjustable door latches – NL35 and NL45 only
The door latches on the NL35 and NL45 models can be adjusted to increase or
decrease door tension on the opening edge of the fridge.
To adjust tension :
- Unclip and fully open the door latch.
- Tighten the brass nut to increase tension or loosen the nut to decrease tension.
- Make small changes, checking the tension between each adjustment. The latch should operate easily with light force. Do not over-tighten.
Take care not to over-tension the door catches or hinges as this can over- compress the door seal or damage the door catch components.
Removing door seal
The door seal can be removed for cleaning simply by pulling from one corner.
Clean and dry the seal and replace by pushing it firmly into the recessed slot
in the lid.
Over time the door seal may become less flexible and not seal completely.
Remove the seal and place in a warm environment, such as in the sun.
This can help the seal to return to its original shape.
If the seal is damaged, replace with a new one.
(spare part available)
Removable hinges – optional accessory
Applications with limited space where it is not possible to fully open the
main door can benefit from removable hinges.
These replace the standard hinges and allow the door to be completely removed
after opening partially.
Remove each of the standard hinges and replace with a removable hinge. Adjust
the door tension if necessary.
Recommended temperature settings
Fruits, vegetables, dairy products, unfrozen meats. | 3°C to 6°C | 37°F to 43°F |
---|---|---|
Cold beverages | 0°C to 5°C | 32°F to 41°F |
Short-term frozen meats | -6°C to -10°C | 21°F to 14°F |
Frozen meats & fish | -10°C to -12°C | 14°F to 10°F |
Ice-cream and frozen deserts | -18°C | 0°F |
Optimising efficiency
Follow these simple tips to reduce your fridge’s energy consumption :
- Keep your fridge in a cool, well-ventilated area.
- Set the internal temperatures appropriate for the contents. Setting temperatures colder than necessary can increase energy consumption.
- Avoid opening the main door more than necessary.
- Load pre-frozen foods into the freezer or freeze the contents when AC power is available.
- Turn off an unused compartment on a Dual-compartment model to reduce energy use.
- Dual-compartment models often have one compartment with thicker insulation and seperate lid. Use this as the freezer if a fridge + freezer combination is used.
- With Dual-compartment models, defrost frozen foods by moving them from the freezer to the fridge compartment. This will help to keep the fridge contents cool and also prevent bacterial growth. Note – This will increase the defrost time so careful planning is required.
Solar panel, battery and inverter sizing
For most remote applications where solar is the primary energy source, a solar
panel size of 100-150W is recommended if 6-8 hours of direct sunlight is
available each day.
This should be combined with a battery of at least 100Ah and solar regulator
suitable for the solar panel used.
A larger battery capacity will allow the fridge to run longer between re-
charges and can extend battery life by reducing the chance of deep discharge.
If the fridge is powered by an AC inverter or generator, it should have a
rating of 150W or more.
The inverter or generator output must be within the fridge AC voltage limits.
Large voltage surges can cause permanent damage to your fridge.
Note – It is more efficient to power a fridge directly from a battery than to use an inverter.
Troubleshooting
In the event of unusual or undesired operation, consult the table below of common fault conditions and potential solutions.
Problem | Possible Cause | Solution |
---|
Fridge will not run when connected to a vehicle or 12V source.
Fridge will only run when battery protection is set to LOW.
Fault-ID light is flashing once every 4 seconds.
| The DC supply may be interrupted or below the minimum operating voltage.
The DC input fuse may be blown.
There is a loose connection or the supply wiring is too thin.
The supply wiring may have too many connections or is improperly installed.
| Recharge the battery if it is low.
Check fuses and connectors in the application wiring. Check the DC input fuse on the fridge.
Replace if necessary.
The supply wiring may be of the incorrect gauge, replace with the recommended size.
Fridge will not run when connected to an AC supply.| The AC supply voltage may
be below the minimum AC voltage rating for the fridge.| Ensure AC supply
voltage is within operating specification.
| The AC plug or cable may be loose or damaged.| Inspect the AC cable.
Replace it if it is damaged.
| The fridge power supply module may be damaged.| Refer the fridge for
service.
The fan is noisy or not running at all.
Fault-ID light is flashing twice every 4 seconds.
| The ventilation fan may be obstructed by debris or excessive dust.
The fan may have a broken blade. The fan may be defective.
| Clear any dust or debris around the fan and ventilation vents.
Refer the fridge for service if the fan is broken or not moving.
Fault-ID light is flashing three or four times every 4 seconds.| The compressor
is unable to start correctly. This can occur if the refrigerant pressure is
too high.| This problem can resolve without intervention after a short period.
Compressor is starting and stopping intermittently.| The compressor or drive
electronics are faulty.| If fault does not resolve, refer the fridge for
service.
Fault-ID light is flashing five times every 4 seconds.| The compressor drive
electronics have over-heated.
This can be a result of blocked ventilation, damaged cooling fan or very high ambient temperature.
| Ensure the ventilation vents are clear.
Check the cooling fan for obstructions or excess dust.
Fault-ID light is flashing six times every 4 seconds.| Compressor drive electronics failure.| Refer the fridge for service.
Specifications
Power Supply
AC supply voltage| 100V – 240V 50/60Hz
DC supply voltage| 9.6V – 32V
Running power| 40W – 75W ( no USB loads connected )
DC input fuse| 15A blade (ATO type)
USB charge (each port)| 24W max : 5V, 9V, 12V
|
Other
Refrigerant type| R134a
Insulation| CFC / HFC free PU
Climate class| T (tropical)
Operating environment| -5°C to +43°C
Communications
Type| Bluetooth® 5.0
Radio frequencies| 2.402 to 2.480 GHz
Safety standards| SANS 60335-1:2018 Ed 3.1
SANS 60335-2-24:2021 Ed 5.2
IEC 60335-1:2016 Ed 5.1
IEC 60335-2-24:2017 Ed 7.2
EN 301 489-1 V2.2.3
EN 301 489-17 V3.2.4
EN 55014-1 / CISPR 14.1
EN 55014-2 / CISPR 14.2
Minimum temperature settings
MODEL | LEFT | RIGHT / SINGLE |
---|---|---|
NL35, NL40, NL45, NL52, NL55, NL65, NL80, NL125 | – | -30°C (-22°F) |
NL50 | -18°C (0°F) | -24°C (-11°F) |
NL60, NL70, NL90 | -24°C (-11°F) | -18°C (0°F) |
NL72, NL110 | -24°C (-11°F) | -24°C (-11°F) |
The BLUETOOTH word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by National Luna is under license. Other trademarks and trade names are those of their respective owners.
While every effort is made to ensure documentation is correct, specifications may change without prior notice.
MODEL | A | B | C | D | E | F | G | H |
---|---|---|---|---|---|---|---|---|
NL35 | 670 | 392 | 430 | 634 | 350 | 765 | 390 | 282 |
NL40 | 635 | 420 | 515 | 600 | 398 | 890 | 371 | 315 |
NL45 | 670 | 392 | 480 | 634 | 350 | 815 | 390 | 282 |
NL50, NL52 | 710 | 385 | 506 | 675 | 360 | 845 | 436 | 284 |
NL55, NL60 | 750 | 425 | 535 | 718 | 400 | 913 | 476 | 324 |
NL65 | 635 | 420 | 715 | 600 | 398 | 1090 | 371 | 315 |
NL70 | 835 | 495 | 475 | 800 | 468 | 920 | 571 | 385 |
NL72, NL80, NL90 | 835 | 495 | 525 | 800 | 468 | 980 | 571 | 385 |
NL110 | 835 | 495 | 706 | 800 | 468 | 1151 | 571 | 385 |
NL125 | 835 | 495 | 735 | 800 | 468 | 1195 | 571 | 385 |
- Dimensions are in mm
- Dimensions are shown for models with the default door configuration.
- While every effort is made to ensure documentation is correct, specifications may change without prior notice.
Serial number and specification label
A unique serial number is located on the rear of the appliance. Take note of
this number when contacting technical support or making a warranty claim.
Do not remove the serial number plate.
This number is also used as the PIN when using the NL CONNECT application on a
mobile device.
A specification label located on the rear panel will indicate the operating
voltages and current rating.
Before connecting your fridge to a power source, make sure the voltage is
within the indicated AC or DC voltage ranges.
A punched hole in the top row will indicate the specific model. Take note of
this model when contacting technical support.
Punched hole denotes model| | | | | | | | | | | | | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
NL MODEL| 35| 40| 45| 50| 52| 55| 60|
65| 70| 72| 80| 90| 110| 125
R134a Refrigerant| 45g| 45g| 45g| 45g| 45g|
45g| 40g| 55g| 45g| 45g| 55g| 45g| 55g|
65g
NATIONAL LUNA OFF-ROAD COMPRESSOR| CLIMATE CLASS| T
---|---|---
DC VOLTAGE RANGE| 12V – 24V| 5A – 3A
AC VOLTAGE RANGE| 100V – 240V 50Hz| 1.1A
SANS 60335-1:2018 Ed 3.1
SANS 60335-2-24:2021 Ed 5.2
IEC 60335-1:2016 Ed 5.1
IEC 60335-2-24:2017 Ed 7.2
Manufactured in South Africa
EN 301 489-1 V2.2.3
EN 301 489-17 V3.2.4
EN 55014-1 / CISPR 14.1
EN 55014-2 / CISPR 14.2
Air transport
This product complies with Special Provision A26 of the Dangerous Goods
Regulations (DGR) listed by International Air Transport Association (IATA) and
International Civil Aviation Organization (ICAO) and is exempt from
declaration as dangerous air cargo based on the following :
This product contains a maximum of 70 grams of non-flammable, non-toxic
refrigerant gas.
This is less than the 12kg limit allowed for safe air transport.
At the end of this products’ life, do not dispose with normal household waste. This appliance should be disposed of responsibly by delivering to an appropriate recycling or waste-disposal facility.
Designed and manufactured in South Africa Issue 4 : March 202336
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>