General notes

Read these original operating instructions and the enclosed safety instructions before using the device for the first time. Act in accordance with them. Keep both books for future reference or for future owners.
Intended use
Only use the appliance in private households. The appliance is intended for cleaning with steam and can be used with appropriate accessories as described in these operating instructions. Detergents are not required. Observe the safety instructions.
Environmental protection
The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations. Electrical and electronic appliances contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which – if handled or disposed of incorrectly – can pose a potential threat to human health and the environment. However, these components are required for the correct operation of the appliance. Appliances marked by this symbol are not allowed to be disposed of together with the household rubbish.
Notes on the content materials (REACH)
Current information on content materials can be found at: www.kaercher.de/REACH
Accessories and spare parts
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely. Information on accessories and spare parts can be found at www.kaercher.com.

Scope of delivery

The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

Safety devices

CAUTION
Missing or modified safety devices Safety devices are provided for your own protection. Never modify or bypass safety devices.

Symbols on the appliance

(according to type of appliance)

  • Risk of burns, surface of appliance becomes hot during operation
  • Risk of scalding from steam
  • Read operating instructions

Pressure controller
The pressure controller keeps the pressure in the steam boiler as constant as possible during operation. The heating is switched off when the maximum operating pressure is reached in the steam boiler and is activated if there is a pressure drop in the steam boiler as a result of a steam removal.
Safety thermostat
The safety thermostat prevents the device from overheating. If the pressure regulator and the boiler thermostat fail and the unit overheats, the safety thermostat switches the unit off. Before resetting of the safety thermostat, contact the responsible KÄRCHER Customer Service.
Boiler thermostat
The boiler thermostat switches off the heating in the event of a fault; for example, if there is no water in the steam boiler and the temperature in the steam boiler rises. As soon as you refill the water, the device is ready for use again.
Maintenance lock
The maintenance lock seals the steam boiler from the steam pressure present. The maintenance cap is also a pressure relief valve. If the pressure regulator is defective and the steam pressure in the steam boiler rises, the pressure relief valve opens and steam is escapes through the lock. Prior to restarting the device, contact the responsible KÄRCHER Customer Service

Device description

The maximum amount of equipment is described in these operating instructions. Depending on the model used, there are differences in the scope of delivery (see packaging). For the figures, please refer to the graphics page Illustration A

KARCHER-1.512-450.0-SC 4-EasyFix-Steam-Cleaner-FIG1

  1. Water reservoir
  2. Filling hole, water reservoir
  3. Switch – On
  4. Switch – Off
  5. Indicator light (green) – heating
  6. Indicator light (red) – water shortage
  7. Carrying handle
  8. Holder for accessories
  9. Holder for accessories
  10. Maintenance lock
  11. Storage for mains connection
  12. Park bracket for floor nozzle
  13. Mains connection cable with mains plug
  14. Non-driven wheels (2 x)
  15. Steering roller
  16.  Steam gun
  17. Steam lever
  18. Unlocking button
  19. Selector switch for steam volume (with child lock)
  20. Steam hose
  21. Spotlight nozzle
  22. Round brush (small)
  23. Power nozzle
  24. Round brush (large)
  25. Manual nozzle
  26. Manual nozzle microfibre cover
  27. Extension tubes (2 x)
  28. Unlocking button
  29. Floor nozzle
  30. Hook and eye connection
  31. Microfibre floor cloth (1 x)
  32. Microfibre floor cloth (2 x)
  33. Carpet glider

SC 4 EasyFix Premium

Installation

KARCHER-1.512-450.0-SC 4-EasyFix-Steam-Cleaner-FIG2 KARCHER-1.512-450.0-SC 4-EasyFix-Steam-Cleaner-
FIG3

Installing accessories

  1. Insert and engage the steering roller and non-driven wheels.
    Illustration B

  2. Push the open end of the accessory onto the steam gun so that the unlocking button on the steam gun engages.
    Illustration I

  3. Push the open end of the accessory onto the spotlight nozzle.
    Illustration J

  4. Connect the extension tubes with the steam gun.

    • Push the first extension tube onto the steam gun so that the unlocking button on the steam gun engages. The connection pipe is connected.
    • Push the second extension tube onto the first extension tube. The connection pipes are connected.
      Illustration K
  5. Push the accessory and / or the floor nozzle onto the free end of the extension tube. The accessory is connected.

Disconnecting accessories

  1. Set the selector switch for the steam volume to the rear. The steam lever is locked.
  2. Push the unlocking button and pull the parts apart.
    Illustration Q

Operation

Filling water
The water reservoir can be removed at any time for filling or be filled directly at the device.
ATTENTION
Damage to the device
Unsuitable water can block the nozzles or damage the water level indicator. Do not fill in pure distilled water. Use a maximum of 50% distilled water mixed with tap water. Do not use condensation from the clothes dryer for filling. Do not use collected rain water for filling. Do not use cleaning agents or other additives (e.g. scents) for filling.
Remove the water reservoir for filling

  1. Pull the water reservoir vertically upwards.
    Illustration C

  2. Fill the water tank vertically with tap water or a mixture of tap water and no more than 50% distilled water up to the “MAX” mark.

  3. Insert the water reservoir and press downwards until it locks into place.

Filling the water reservoir directly on the device

  1. Fill tap water or a mixture of tap water and no more than 50% distilled water from a vessel into the filling hole of the water reservoir up to the “MAX” mark.
    Illustration D

Switch on the device
Note
If there is no or too little water in the steam boiler, the water pump starts to run and pumps water from the water reservoir into the steam boiler. The filling process can take several minutes.
Note
The device briefly closes the valve every 60 seconds causing an audible soft click. Closing prevents the valve from clogging. This does not affect the steam output.

  1. Place the device on a firm surface.

  2. Insert the mains plug into a socket.
    Illustration E

  3. Press the ON switch.
    The green heating indicator light flashes.
    Illustration F

  4. Wait until the green heating indicator stays on.
    Illustration G

  5. Press the steam lever.
    Illustration H
    Steam leaks out

Regulating the steam volume
The expelled steam volume is regulated using the selector switch for steam volume. The selector switch has 3 positions:

  Maximum steam volume
  Reduced steam volume
  No steam – child lock

Note

In this position, the steam lever cannot be operated.

  1. Set the selector switch for the steam volume to required steam volume.
  2. Press the steam lever.
  3. Before starting cleaning, point the steam gun at a cloth until steam is expelled evenly.

Refilling water
If there is not enough water, the water shortage indicator lamp flashes red and a signal tone sounds.
Note
The water pump fills the steam boiler at intervals. If the filling is successful, the red water shortage indicator lamp goes out.
Note
If there is no or too little water in the steam boiler, the water pump starts to run and pumps water from the water reservoir into the steam boiler. The filling process can take several minutes.
ATTENTION
Damage to the device
Unsuitable water can block the nozzles or damage the water level indicator. cDo not fill in pure distilled water. Use a maximum of 50% distilled water mixed with tap water.  Do not use condensation from the clothes dryer for filling. Do not use collected rain water for filling. Do not use cleaning agents or other additives (e.g. scents) for filling.

  1. Fill the water tank with tap water or a mixture of tap water and no more than 50% distilled water up to the “MAX” mark. The device is ready for use.

Switching off the device

  1. Press the OFF switch.
    Illustration O
    The device has been switched off.

  2. Press the steam lever until no more steam flows out.
    Illustration P
    The steam boiler is depressurised.

  3. Set the child lock (selector switch for steam volume) to the rear. The steam lever is locked.

  4. Pull the mains plug out of the socket.

  5. Drain the water reservoir.

Rinsing out the steam boiler
Rinse the device’s steam boiler out after every tenth filling of the tank.

  1. Switch the device off; see Chapter Switching off the device.

  2. Allow the device to cool down.

  3. Drain the water reservoir.

  4. Remove the accessory/accessories from the accessory holders.

  5. Open the maintenance lock. To do this place the open end of an extension tube on the maintenance lock, insert this into the guide so it engages and open it.
    Illustration T

  6. Fill the steam boiler with water and swing it around vigorously. Lime residue which has been deposited on the bottom of the steam boiler will be released as a result.

  7. Drain the water completely out of the steam boiler.
    Illustration U

Storing the device

  1. Connect the extension tubes to the large mounts for accessories.

  2. Connect a manual nozzle and spotlight nozzle to each extension tube.

  3. Fasten the large round brush to the spotlight nozzle.

  4. Connect the small round brush and nozzles to the medium-sized mount for accessories.

  5. Hang the floor nozzle in the park bracket.
    Illustration R

  6. Wind the steam hose around the extension tube and connect the steam gun to the floor nozzle.
    Illustration S

  7. Wind the mains cable around the extension tube.

  8. Stow the mains cable in the accessory compartment.

  9. Store the device in a dry location that is protected from frost

Important application instructions

Cleaning the floor areas
We recommend sweeping the floor or vacuum cleaning it before using the appliance. In this way the floor will be cleared of dirt and loose particles before the wet cleaning.
Freshening up textiles
Prior to using the appliance, always check the compatibility of the textiles at a concealed point: Steam down the textile, allow it to dry and then check it for any change in colour or shape. Cleaning coated or painted surfaces
ATTENTION
Damaged surfaces
Steam can loosen wax, furniture polish, plastic coatings or paint and edge band from edges.  Do not direct the steam at glued laminated edges as the edge band may loosen. Do not use the appliance for cleaning unsealed wood or parquet floors. Do not use the appliance for cleaning painted or plastic coated surfaces such as kitchen or living room furniture, doors or parquet.

  1. To clean these surfaces, steam a cloth briefly and use it to wipe over the surfaces

Glass cleaner
ATTENTION
Glass breakages and damaged surfaces
Steam can damage sealed points of the window frame and, at low outside temperatures, lead to tension on the surface of window panes and hence to glass breakages. Do not direct the steam at sealed points on the window frame. At low outside temperatures, heat up the window panes by gently steaming the full surface of the glass.

  • Clean the window area with a manual nozzle and cover. To remove the water, use a squeegee or wipe the surfaces dry.

How to use the Accessories

Steam gun
The steam gun can be used for the following applications without accessories:

  • For removing slight creases from the hanging clothing items: Steam the clothing item from a distance of 10-20 cm.
  • For wiping damp dust: Steam a cloth briefly and use it to wipe over the furniture.

Spotlight nozzle
The spotlight nozzle is suitable for cleaning areas, joins, fittings, drains, sinks, WCs, blinds or radiators that aredifficult to access. The closer the spotlight nozzle is to the soiled area, the greater the cleaning efficiency will be as the temperature and steam volume are at their highest at the nozzle opening. Larger lime deposits can be treated before steam cleaning with a suitable detergent. Allow the detergent to soak in for approx. 5 minutes and then steam it off.

  1. Slide the spotlight nozzle onto the steam gun.
    Illustration I

Round brush (small)
The small round brush is used for cleaning stubborn dirt. Stubborn dirt can be removed more easily by brushing.
ATTENTION
Damaged surfaces
The brush may scratch sensitive surfaces. It is not suitable for cleaning sensitive surfaces.

  1. Fit the round brush to the spotlight nozzle.
    Illustration J

Round brush (large)
The large round brush is suitable for cleaning large rounded surfaces, e.g. wash basin, shower tray, bath tub, kitchen sink.
ATTENTION
Damaged surfaces
The brush may scratch sensitive surfaces. It is not suitable for cleaning sensitive surfaces.

  1. Fit the large round brush to the spotlight nozzle.
    Illustration J

Power nozzle
The power nozzle is used for cleaning stubborn dirt, blowing down corners, joins etc.

  1. Install the power nozzle onto the spotlight nozzle according to the round brush.Illustration J

Manual nozzle
The manual nozzle is used for cleaning small areas that can be washed down, shower cubicles and mirrors

  1. Push the manual nozzle onto the steam gun according to the spotlight nozzle.
    Illustration I

  2. Pull the cover over the manual nozzle

Care and service

KARCHER-1.512-450.0-SC 4-EasyFix-Steam-Cleaner-FIG4

Descaling the steam boiler
Note
Since the lime clogs the appliance, we recommend descaling the appliance based on the number of times the water reservoir is filled as specified in the table (TF=tank fillings).

Hardness range °dH mmol/l TF
I soft 0-7 0-1.3
II Medium 7-14 1.3-2.5
III Hard 14-21 2.5-3.8
IV Very hard >21 >3.8

Note
Your water board or municipal utilities authority can provide information on hardness of tap water.
ATTENTION
Damaged surfaces
The descaler may corrode sensitive surfaces. Fill and empty the appliance carefully.

  1. Switch off the appliance, see Chapter Switching off the device.

  2. Allow the appliance to cool down.

  3. Drain the water reservoir.

  4. Remove the accessory/accessories from the accessory holders.

  5. Open the maintenance lock. To do this place the open end of an extension tube on the maintenance lock, insert this into the guide so it engages and open it.
    Illustration T

  6. Drain the water completely out of the steam boiler.
    Illustration U
    ATTENTION
    Appliance damage due to descaler An unsuitable descaler or incorrect dosing of the descaler may damage the appliance. Only use KÄRCHER descaler. Use 1 dosing unit of the descaler for 0.5 l water.

  7. Apply descaler solution to the descaler according to the details.

  8. Fill the descaler solution into the steam boiler. Do not seal the steam boiler.

  9. Allow the descaler solution to take effect for approx. 8 hours.

  10. Drain descaler solution completely out of the steam boiler.

  11. Repeat the descaling process if necessary.

  12. Rinse the steam boiler 2-3 times with cold water in order to drain all the descaler solution residue.

  13. Drain the water completely out of the steam boiler.

  14. Dry the mounting for the grid connection cable.

  15. Close the maintenance lock with an extension tube

Care of accessories
(Accessories – depending on scope of delivery)
Note
The floor cleaning cloth and the cover for the manual nozzle have been washed beforehand and can be used immediately for working with the appliance. The micro fibre cloths are not suitable for dryer.
Note
When washing the cloths, observe the instructions on the washing tag. Do not use any liquid softeners as this will affect the ability of the cloths to pick up dirt.

  1. Wash the floor cleaning cloths and covers at a max. temperature of 60 °C in the washing machine

Troubleshooting guide

Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.
WARNING
Risk of electric shock and burns
Trying to eliminate faults while the appliance is connected to the mains or has not yet cooled down is always dangerous.
Remove the mains plug. Allow the appliance to cool down. The steam boiler is scaled.

  • Descale the steam boiler

The water shortage indicator light flashes red and a signal tone sounds No water in the tank.

  • Fill the water reservoir up to the “MAX” marking.

The water shortage indicator light is lit in red No water in the steam boiler. The pump’s overheat protection has triggered.

  1. Switch the device off; see Chapter Switch off the device.
  2.  Fill the water reservoir.
  3. Switch on the device; see Chapter Switching on the device.

The water tank is not inserted correctly or is calcified.

  1. Remove the water reservoir.
  2. Rinse the water reservoir.
  3. Insert the water reservoir and press downwards until it locks into place

The steam lever cannot be pressed
The steam lever is locked with the child lock.

  • Set the child lock (selector switch for steam volume) to the front. The steam lever is released.

Long heating-up time

The steam boiler is scaled.

  • Descale the steam boiler.

High water output
The steam boiler is scaled.

  • Descale the steam boiler.

Technical data

Electrical connection

Voltage| V| 220-240
Phase| ~| 1
Frequency| Hz| 50-60
Protection class|  | IPX4
Protection category|  | I
Performance data|  |
Heating capacity| W| 2000
Maximum operating pressure| MPa| 0.35
Heating-up time| Minutes| 4
Continuous steaming| g/min| 50
Maximum steam blast| g/min| 110
Filling quantity|  |
Water reservoir| l| 0.8
Steam boiler| l| 0.5
Dimensions and weights|  |
Weight (without accessories)| kg| 4.1
Length| mm| 350
Width| mm| 280
Height| mm| 270
Subject to technical modifications.|  |