LONGOT TECHNIC K3 Pro Multi Function Thermal Monocular User Manual
- June 9, 2024
- LONGOT TECHNIC
Table of Contents
LONGOT TECHNIC K3 Pro Multi Function Thermal Monocular
DISCLAIMER
This product is prohibited for illegal use, including illegal hunting,
military, chemical, biological or nuclear weapons, illegal privacy
photographing, and other violations of laws and regulations. It is prohibited
to transport goods prohibited by the United Nations, the European Union or the
OSCE. The products are only sold in the place where the company is registered
and cannot be exported.
Purchase of this machine is equivalent to accepting the constraints of this
statement, equivalent to agreeing to sign the relevant liability statement. In
case of any violation, the company shall not be held responsible.
LONGOT TECHNIC
Device Information
This multi-function thermal monocular can be used for target search and ostentation at night, in dim, no light conditions, sender weather conditions and other complicated scenarios. It is low in Swaps and has long battery life, can be head-mounted, handheld, thermal scope mounted and clip-on thermal scope mounted. It is widely applied in law enforcement, outdoor ostentation, wild adventure, sea arch and rescue, and other fields.
Package details
① Device
② Helmet adapter bracket(optional)
③ Picatinny rail adapter
④ Clip-on hoop
⑤ Thermal scope eyecup
⑥ Cables
⑦ User manual
⑧ Charger and wiring
⑨ Battery
⑩ Warranty card
Device Parameters
Model | K3 Pro | K6 | K 9 |
---|---|---|---|
Pixel Pitch,μm | 12 | 12 | 12 |
Resolution | 384 ‘288 | 384 ‘288 | 640’512 |
Frame Rate,Hz | 50 | 50 | 50 |
Response wave band | 8-14μm | 8-14μm | 8-14μm |
Display, OLED | 1024X768 | 1024X768 | 1024X768 |
Focal Length of Objective Lens | 16mm F-1.0 | 27mm f-1.0 | 27mm f-1.0 |
FOV | 16.3°X 12.3° | 9.a · x1.4• | 16.3 X 12.3″ |
Magnification | lx | l.7x | lx |
Diopter Adjustment | 5, * 2 | 5, * 2 | 5, * 2 |
Exit Pupil Diameter | 12mm | 12mm | 12mm |
Exit Pupil Diameter | 20mm | 20mm | 20mm |
Polarity | Black heat, White heat, Red heat, Rouge, Colorl.Color2 | ||
Mode | Outdoor ,Arctic, Rainforest. Bird, Observation | ||
Digital Zoom | 1-4x | l-8x | l-8x |
Digital Compass | Azimuth, Pitch, Roll | ||
Wi-Filmage Transmission | Support | ||
Image/Video Capture | Support | ||
Battery | l X 18650 (3. N) | ||
M ax. Banery Li le | >6h | >6h | >5h |
Reticle type | 7 Multiple modes | ||
Reticule color | White / Black / Red / Invert Colors | ||
Motion sensor | Support | ||
Laser Pointer | Support | ||
Targel type | 1500m | 2550m | 2550m |
Weight (w/o battery | 356g(<318g) | 378g(<340g) | 378g(<340g) |
Dimension(mm} | 120·12·44 | ||
Mounting Type | H and held, h1 >ad I hl’rmal \COPI’, **clip- |
on lht-rmal ~c-o p .. , k6 n ot wpport )
Waterproof| 20•c~4o•c / 4o•c 4o•c (optional)
O p era t i n g Tempe r atu r e
Range| I P 67
Shock| 6000J
Vibration| 6.06G**
Note: Max. detection range of an object meaning:l.7xl.2 meter target in natural nigh conditions. The distance is affected by temperature, humidity, weather ,anc environment etc.
Installation and Power on
Product Mounting and Dismounting
There are four usage types: handheld, head-mounted, thermal sight, clip-on thermal sight. Different accessories and mounting types for different usages. Install battery first before use.
Battery Installation
Support 18650 battery (Battery diameter :18mm± length: 65mm±O.S)
Handheld
No accessories are needed for handheld use, the monocular can be used directly after the battery is installed, hand held use by default.
Head-mounted Use
The head-mounted adapting bracket (optional) should be installed after the battery is inserted, the mounting procedures are as follows:
- Remove the head-mounted adapting bracket, fix the set screw of the bracket into the holes of the deceive;
- Put the deceive onto the standard helmet support;
Note: The flip image should be set first in the system menu for head- mounted use.
Thermal Sight Use
The Picatinny rail adapter should be installed on the device after the battery is inserted for thermal sight use, then mount the device onto the Picatinny rail, the installation procedures are as follows:
- Remove the Picatinny rail adapter, and mount it on the two screw holes with 2 • MS screws;
- Change eyecup, remove the U-shaped eyecup and install the thermal sight eyecup onto the diopter adjustment wheel of the eyepiece;
- Mount the monocular installed with rail adapter to the Picatinny rail.
Note: you should pull out the U-shaped eyecup from the bottom part, dragging the outer parts may cause eyecup damage.
Clip-on Sight Use
The clip-on hoop should be installed on the monocular after battery insertion during clip-on sight use, then mount the monocular on the optical sight, the installation procedures are as follows:
- Remove the U-shaped eyecup, and mount it on the two screw holes with 2 • MS screws;
- Mount the monocular installed with clip-on hoop onto the objective lens of daylight optical sight.
Note: You should pull out the U-shaped eyecup from the bottom part, dragging the outer parts may cause eyecup damage. The diameter of the daylight sight must be between 40 and 45mm to mate with the clip-on hoop.
Power On
Remove the objective lens cap before power on, long press On/Off button for 2s, the start-up Logo will appear on the screen, the image will be presented after shutter correction.
Operation Introduction
Operations on Main Interface
l Main Menu Display
The display information on Main Menu includes: infrared image, battery capacity, azimuth, pitch, roll, digital zoom magnification, image polarity, the reticle (display after setup in the menu). PIP (display after setup in the menu);
No.
| Icon|
Descriptions
---|---|---
1| Compass| Di play W, NW, N, NE, E, SE, S, S\V, with angle value
2| Laser Icon| Display laser On/Off status
3| Battery Capacity lndicaion| 4 scale for full battery , the icon will turn
to red when the battery is less then 10%
4| Reticle| not displayed by default, displayed after setup ,n menu
5| Pitch| -90° .. 90°
6| Roll| -90° .. 90°
7| PIP| full Screen digital 100m by default , displayed after setup in he menu
8| Image Polarity| Black heat, Wlh1te heat, Red heat, Rouge. Color 1 ,Color2
9| Video Recording| Video recording prompt
10| Image Capture| Image capture prompt
11| D1g1tal Zoom| Support 1-4 x (384 X288), support l -8X (640 X512)
12| Wi- Fi| Display Wi-Fi function
Digital Zoom
Rotate the knob lo adjust the digital zoom on the main Menu,
full-screen display of digital zoom by default.
Support l •4x for 384×288 thermal resolution product,
image-centered lx/2x/3x/4x magnification;
Support l ·8x for 640×512 thermal resolution product,
image-centered lx/2x/4x/6x/8x magnification ;
Mode Switch
Short press the knob to change image mode on the main Menu, and support cyclic switch among Black heal, White heal, Red heal, Rouge, Colorl,Color2.
Manual Image Correct ion
When there is blur, degradation, brightness uniformity or halo on the main Menu, the shutter correction should be performed. Long press ② for 3s to perform manual shutter correction, when you can hear the shutter click, the correction time is less than ls.
Image Capture
Short press button ③ to capture an image on the main menu, the image file will be named and saved according to the current time.
Video Recording
Long press ③ to record videos on the main menu, the video file will be named and saved according to the current time, the max recording time is 30min.
Menu Operations
Long press the knob to enter the menu on the main menu, you can perform image settings, scenario settings, display settings and other settings under menu mode.
Brightness
The brightness level is higher, the image grows brighter. When the main interface is too dark, users can adjust the brightness to adjust the clarity of image displayed. The adjustment range is 1-10, 5 by default.
Contrast
The contrast level is higher, the chiaroscuro and colors contrast is more obvious. users can adjust the contrast lo highlight different targets in complex environments. The adjustment range is 1-10, 5 by default.
Scene mode
Short press the menu button to change the scene mode: observation, arctic,
forest, bird. Different scene modes correspond to different operating
environments.
Users can select proper scene mode to get the better image effect in
previewing.
Wi-Fi
Short press to enable or disable WIFI. The device supports WIFI connection. Users can connect with cellphone by WIFI lo build wireless internet connection.(initial password:12345678)
Video output
Short press to enable or disable video output. After enabling it, users can connect the external display by Type-C cable. It could output the video for extending display and zooming in to check the details of image.
Auto flip
Short press to enable or disable the automatic flip. Automatic flip can automatically adjust the screen aimed at the direction of device.
PIP
Short press the menu button to enable or disable the PIP function. The PIP is the image of zooming in the center of scene partial ly and overlapping in the preview interface, users can open t he PIP to check the details of critical image
Reticle settings
Reticle display
Set reticle display, reticle style, reticle color and reticle movement enable
or disable.
Reticle memory
When the reticle is enabled, users cam select the different reticle memory groups by themselves if the device shares between with many person or has many requirements of reticle setting. Each memory group can independently configure different reticle types. (1-5 memory groups)
Reticle style
When the reticle is enabled, short press the menu button to switch reticle style.(lt has 7 kinds)
Reticle color
When the reticle is enabled, short press the menu button to switch the reticle color(white, black, green and invert color). Please select proper color for recognizing conveniently according to the color of environment. The invert color has adaptive color. (E.g.: the reticle color will change automatically to black if the target is too bright.)
Freezing and calibration
Freezing: Fix the device firmly and short press menu button after shooting to freeze the image. Observing the point of impact in the freezing image, users select “horizon·· (left and right) or “vertical” (up and down) and rotate the button to move the center of reticle to coincide with the point of impact. The parameter will save automatically after exiting and the calibration is finished.
Calibration: Fixing the device firmly and put a piece or lighted cigarette or other heat sources in the point of impact after shooting. Observing the point or impact in the freezing image, users select “horizon• (left and right) or “vertical” (up and down) and rotate the button to move the center of reticle to coincide with the point of impact. Tile parameter will save automatically after exiting and the calibration is finished.
Reset
If any memory group needs to reset the calibration point, users can select reset to restore the current reticle parameters to default.
Other settings
Compass: Display of compass information, pitch angle, roll angle enable
or disable, enable by default.
Azimuth calibration: It is mainly used to calibrate the
azimuth. which is recommended to be performed for the first use or the place
of use is changed. The calibration operation instructions will be presented
after azimuth calibration is selected: rotate 360° horizontal centered by the
device itself and cl ick start then rotate, click OK to finish calibration
after rotation.
Pitch calibration: It is mainly used to calibrate the pitch angle. The
calibration operation instructions will be presented after pitch calibration
is selected: rotate 1so• horizontal centered by the device itself and click
start then rotate, click OK to finish calibration after rotation.
Language: User can switch between Chinese and English according to the
situation.
System time: Short press menu button to switch year, month, day, hour,
min or second. Rotate the button to adjust the time and confirm to finish.
Auto shutter: It can adjust time interval between shutter corrections.
The options are 3,5,7, auto, and off.
Restore to factory default settings: Confirm to restore to factory
default settings will be appear, the device will restore to factory default
settings and exit all menus after Yes is selected.
Device status: It shows the operation time and SN code.
Notice: The operation time will be reset after resetting factory default
settings.
Format: Delete all pictures and videos. Please cautiously use to prevent
being mistaken delete
Malfunction and Correction Actions
The common malfunctions of K series are listed in the below Table, please
check and perform the corresponding corrective actions listed in Table 4,1.
Please confirm whether the problem has. been solved after corrective actions.
Not MI possible malfunctions are listed in Tatrlemtip it t he malfunctions not
Iisl d appear or the problem can not be solved alter corrective actions,
please seek higher. level maintenance.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any Changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment. Note: This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help. The SAR
limit adopted by USA is 1.6 watts/kilogram (W/kg) averaged over one gram of
tissue. The highest SAR value reported to the Federal Communications
Commission (FCC) when it is tested for use at the body is 0.614W/kg, and the
head is 0.106W/kg. The device complies with the RF specifications when the
device is used near your head or at a distance of 0 mm from your body. Ensure
that the device accessories such as a device case and a device holster are not
composed of metal components.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>