Ruffneck FX5 Electric Heaters Wall Mounting Kit Instruction Manual
- June 9, 2024
- Ruffneck
Table of Contents
FX5/FX6/FE2 Electric Heaters
Wall Mounting Kit Installation Instructions
FX5 Electric Heaters Wall Mounting Kit
WARNING. If the heater is installed on a structure that is to be transported, provide additional support for the heater during transit. The suspended weight should not exceed 250 lbs (114 kg). Refer to the unit heater owner’s manual for the mounting specifications and conditions.
Check that your heater model number corresponds to the model number shown on the mounting kit carton (see Table 2).
Step 1
Fasten Z-Sections (#1) to a surface or structure that will support the
heater’s weight using the installer supplied fasteners.
Note: Installer to supply four 3/8″ diameter, grade 5 bolts or equivalent
strength fasteners.
Step 2
Bolt the Arm Assembly (#2) to the Z-Section (#1) using 3/8″-16 UNC X 1″ Bolts
(#5), Locking Washers (#8) and 3/8″-16 UNC Nuts (#11).
Step 3
Bolt Mounting Bracket Attach Assembly (#3) to the heater’s top panel using two
1/2″-13 UNC Bolts (#4), Nuts (#10), Flat Washers (#12) and 1/2″ Locking
Washers (#7).
N Mounting Attach Assembly Bracket (#3) must be placed with the threaded hole
closest to the control enclosure side of the heater, attach to heater using
the rear two holes on top panel.
Step 4
Lift the heater into place and fasten it to the Arm Assembly (#2) using a
5/8″-11 UNC X 1 1/4″ Bolt (#6) and 5/8″ Locking Washer (#9).
CAUTION. This step will require more than one person due to the weight of
the heater. Refer to the unit heater owner’s manual for the weight of the
heater.
Table 1 – Contents
Item | Qty | Description | Part No. |
---|---|---|---|
1 | 2 | Angle, wall mounting kit support | 3152 |
2 | 1 | Arm, mounting | 9706 |
3 | 1 | Mounting Bracket Attach Assembly | 12″ – 9675 |
16″ – 9676
20″ – 9677
4| 2| Bolt 1/2-13UNC x 1 1/4 long, hexagon head| 2940
5| 4| Bolt 3/8-16UNC x 1 1/4 long, hexagon head| 3153
6| 1| Bolt 5/8-11UNC x 1 1/4 long, hexagon head| 3122
7| 2| Lockwasher 1/2″ ID split| 4373
8| 4| Lockwasher 3/8″ ID split| 3159
9| 1| Lockwasher 5/8″ ID split| 3093
10| 2| Nut 1/2-13 UNC hexagonal| 4372
11| 4| Nut 3/8-16 UNC hexagonal| 2785
12| 2| Washer, flat 1/2″| 2941
Table 2 – Wall Mounting Kit
FX5/FX6/FE2 Heater Cabinet Size | Part No. |
---|---|
12″ | 9730 |
16″ | 9731 |
20″ | 9732 |
WARRANTY: Under normal use the Company warrants to the purchaser that
defects in material or workmanship will be repaired or replaced without charge
for a period of 18 months from date of shipment, or 12 months from the start
date of operation, whichever expires fi rst. Any claim for warranty must be
reported to the sales offi ce where the product was purchased for authorized
repair or replacement within the terms of this warranty.
Subject to State or Provincial law to the contrary, the Company will not be
responsible for any expense for installation, removal from service,
transportation, or damages of any type whatsoever, including damages arising
from lack of use, business interruptions, or incidental or consequential
damages.
The Company cannot anticipate or control the conditions of product usage and
therefore accepts no responsibility for the safe application and suitability
of its products when
used alone or in combination with other products. Tests for the safe
application and suitability of the products are the sole responsibility of the
user.
This warranty will be void if, in the judgment of the Company, the damage,
failure or defect is the result of:
- Vibration, radiation, erosion, corrosion, process contamination, abnormal process conditions, temperature and pressures, unusual surges or pulsation, fouling, ordinary wear and tear, lack of maintenance, incorrectly applied utilities such as voltage, air, gas, water, and others or any combination of the aforementioned causes not specifi cally allowed for in the design conditions or,
- Any act or omission by the Purchaser, its agents, servants or independent contractors which for greater certainty, but not so as to limit the generality of the foregoing, includes physical, chemical or mechanical abuse, accident, improper installation of the product, improper storage and handling of the product, improper application or the misalignment of parts.
No warranty applies to paint fi nishes except for manufacturing defects
apparent within 30 days from the date of installation.
The Company neither assumes nor authorizes any person to assume for it any
other obligation or liability in connection with the product(s).
The Purchaser agrees that all warranty work required after the initial
commissioning of the product will be provided only if the Company has been
paid by the Purchaser in full accordance with the terms and conditions of the
contract.
The Purchaser agrees that the Company makes no warranty or guarantee, express,
implied or statutory, (including any warranty of merchantability or warranty
of fi tness for a particular purpose) written or oral, of the Article or
incidental labour, except as is expressed or contained in the agreement
herein.
LIABILITY: Technical data contained in the catalog or on the website is
subject to change without notice. The Company reserves the right to make
dimensional and other design changes as required. The Purchaser acknowledges
the Company shall not be obligated to modify those articles manufactured
before the formulation of the changes in design or improvements of the
products by the Company.
The Company shall not be liable to compensate or indemnify the Purchaser, end
user or any other party against any actions, claims, liabilities, injury,
loss, loss of use, loss of business, damages, indirect or consequential
damages, demands, penalties, fi nes, expenses (including legal expenses),
costs, obligations and causes of action of any kind arising wholly or partly
from negligence or omission of the user or the misuse, incorrect application,
unsafe application, incorrect storage and handling, incorrect installation,
lack of maintenance, improper maintenance or improper operation of products
furnished by the Company.
PLEASE ADHERE TO INSTRUCTIONS IN THIS MANUAL Failure to do so may be dangerous and may void certain provisions of your warranty.
Visit www.thermon.com to contact a Thermon
representative near you.
HEAD OFFICE: 7171 SOUTHWEST PKWY | BUILDING 300 SUITE 200 | AUSTIN, TX | 78735
| UNITED STATES
RUFFNECK: 5918 ROPER ROAD | EDMONTON, AB | T6B-3E1 | CANADA
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>