hoymiles HM-800 Series 2 to 1 Micro Inverter Installation Guide

June 4, 2024
hoymiles

HM-800 Series Quick Installation Guide
*Applicable to HM-600/700/800 microinverters
Installation Guide
hoymiles HM 800 Series 2 to 1 Micro Inverter
-

Accessories

Item Description
A AC End Cable (Female), 2 m 12 AWG Cable
B M8 × 25 Screws
C DC Extension Cable, 1 m
D AC Female End Cap, IP67

*Note: All accessories listed above are not included in the package, and need to be purchased separately. Please contact our sales representative for pricing information. (M8 screws need to be prepared by the installer.)

Installation Steps

Ensure the microinverter is installed in the required environment. (Refer to the product user manual for more details.)

Step 1. Attach Microinverter on Rail
A) Mark the approximate center of each panel on the frame.
B) Fix the screw on the rail.
C) Hang the microinverter on the screw (as shown in the picture), and tighten the screw. The silver cover side of the microinverter should be facing the panel.

*Note: Please install the microinverter at least 50 cm above the ground/roof for better communication with the Hoymiles DTU.

Step 2. Connect AC Cables of Microinverter

A) Plug the AC connector of the first microinverter into the connector of the second microinverter to form a continuous AC branch *circuit.hoymiles HM
800 Series 2 to 1 Micro Inverter - Cables of
Microinverter Note:** The length of the AC cable on the microinverter is around 2.04 m. Use AC extension cable if two microinverters are more than 2.04 m apart.hoymiles HM 800
Series 2 to 1 Micro Inverter - microinverters B) Install the AC end cap on the open AC connector of the last microinverter in the AC branch circuit.hoymiles HM 800 Series 2 to 1
Micro Inverter - last microinverter

Step 3. Connect AC End Cable

A) Make the AC end cable.

  1. Separate the AC port into 3 parts.hoymiles HM 800 Series 2 to 1 Micro Inverter - End Cable

  2. Insert the AC cable through Part 3 into Part 2, and complete the wiring for the L, N, and Ground inside the AC port in Part *1.hoymiles HM 800 Series 2 to 1 Micro Inverter - into Part Note:** L: Brown wire
    N: Blue wire
    G: Yellow/Green wire
    Please use a 12 AWG cable as the AC end cable.

  3. Plug the AC port Part 2 into Part 1 once the wiring is complete, and then screw on Part 3 to complete the AC extension cable.hoymiles HM 800 Series 2 to 1 Micro Inverter - screw on Part B) Connect the AC end cable to the AC male connector of the first microinverter to complete the circuit.hoymiles HM 800 Series 2 to 1 Micro Inverter - cable to the AC male C) Connect the other side of the AC end cable to the distribution box, and wire it to the local grid network.

Step 4. Create an Installation Map

A) Peel the removable serial number label from each microinverter (the position of the label is shown below).
B) Affix the serial number label to the respective location on the installation map.

hoymiles HM 800 Series 2 to 1 Micro Inverter - number
label

Step 5. Connect PV Modules

A) Mount the PV modules above the microinverter.
B) Connect the PV modules’ DC cables to the DC input side of the microinverter.

hoymiles HM 800 Series 2 to 1 Micro Inverter - DC
cables

Step 6. Energize the System
A) Turn on the AC breaker of the branch circuit.
B) Turn on the main AC breaker of the house.
Your system will start to generate power in about two minutes.
Step 7. Set Up the Monitoring System
Refer to the DTU User Manual, DTU Quick Installation Guide, and Quick Installation Guide for S-Miles Cloud to install the DTU and set up your monitoring system.

Product information is subject to change without notice.