FootfallCam 3D PRO2 People Counter Installation Guide
- June 9, 2024
- FootfallCam
Table of Contents
FootfallCam 3D PRO2 People Counter Installation Guide
What Installer Need To Bring
- Screw drivers and drill
- RJ45 crimp tool: To terminate Cat5e network cable
- Ladder: Ladder type depends on the ceiling height
- Laptop: To diagnose counter (Optional)
- Cat5e network cable: Cable length depends on distance between the router and the counter
Part 1 Determine the Correct Counter Position
IMPORTANT
Please make sure the counter live view is not blocked by any drop down
obstacle (e.g. decorations, exit signage, bulk head, wall, etc.). Otherwise,
accuracy of the result may be affected due to the limited tracking zone.
To calculate the required clearance distance between counter and the drop down obstacle, please access www.footfallcam.com/Calculator.
(Optional) Requirement for Staff Exclusion Tag Implementation
-
For sliding doors, position FootfallCam at least 1m away from the door. For swing doors, position FootfallCam at least 1m away from the edge of the door when open widest. Recommended ceiling height is 2.5m – 3.2m. Counter may not be able to detect the staff exclusion tag if the counter is not installed within the recommended ceiling height.
-
Make sure the live view is not blocked by any obstacle. Please send a screenshot of the Live View page to the
FootfallCam Support Team via FootfallCam Support Chat App, and let us know if the staff exclusion tag will be used in this site. -
Peel off the protective film on the Staff Exclusion Tag before use.
**Kindly refer to Appendix A: Staff Exclusion Tag for more details.
Part 2 Wiring Setup Instruction
LED LIGHT INDICATIONS
Note: Kindly refer to Appendix E: Installation Completion Checklist for more details.
Part 3 Configuring the Counter
Read More About This Manual & Download PDF: