AlzaErgo APW-EGET7000 Control Panel User Manual

June 9, 2024
AlzaErgo

AlzaErgo -logo User Manual

AlzaErgo APW EGET7000 Control Panel-

Control Panel
APW-EGET7000

OVERVIEW

AlzaErgo APW EGET7000 Control Panel-overview

1 Up
2 Down
3 Pre-set Settings 1/2/3
4 Pre-set Setting
5 Timer
6 Display
7 Indicator| Adjusting the table height
Adjusting the table height
Adjusting the table height to one of the three pre-set settings
Saving pre-set settings
Setting timer to change the working position
Shows the table height and other relevant information
Shows the timer setting
---|---

HOW TO USE THE CONTROL PANEL

Once connected to a power source, you’ll hear a beeping sound and the actual height of the table will show on the display.
Safety Standby Mode
The safety standby mode is automatically activated when there’s no ac- tivity performed after 60 seconds.
To unlock the control panel press any button.
Changing the Table Height
To adjust the table height, use the up o r down buttons to the preferred position.
Pre-set Setting
To save a given height as a pre-set setting, press the M button. The dis- play will show S-. Afterwards, press one of the buttons 1, 2 o r 3 within 5 seconds. Each of these buttons (1, 2 and 3 ) allow you t o save a pre-set table height setting.
To activate the given pre-set setting, just press down on one of the but- tons that you have previously set (1, 2 and 3).
Please Note: Press any of the buttons (other than the T button) to stop the table from adjusting in height.
Reset
The table must be plugged into a power source. To reset the settings , press the down button until the table is in the lowest position. After – wards, hold the down button once again until the desk of the table moves up and stops. The reset is now complete and you can adjust the table position as desired. During the reset, the display shows r SE.
Timer
The timer is used to indicate a change in a working position. As soon as the set timer elapses, a beep will sound.
To activate the timer, press the T button. The display will flash with 0.5h.
To extend the timer in 30 minute intervals , press the T button again. The timer can be set up to 2 hours. The timer is set a s soon as the display stops flashing with the set time interval, and the indicator in the upper right hand corner of the control panel lights up. As soon a s the set time interval passes, you’ll hear a beeping sound that indicates that the timer has run out .
To cancel the timer, press the T button repetitively until the indicator light turns off in the upper right hand corner o f the control panel.

Changing the Units
The control panel display is pre-set with the units in centimetres. To change this, restart the system by unplugging and plugging back in the power cord, and press down the T button down for 3 seconds. The units will change to inches, which is indicated with two beeping noises. If you’d like to change the units back to centimetres, repeat the steps mentioned above. You’ll know that the units have changed to centime-tres when you hear one beep. Collision Avoidance Settings Press and hold the M and T buttons together for 5 seconds until you hear the controller beeps twice indicating you are in the Collision Avoidance Settings Mode. The screen of the controller will display the current sensitivity level (level 3 by default) Press the ▲ or ▼ button to adjust the desired sensitivity level. When you are finished selecting the new level, press the M button to save the sensitivity level. The Collision Avoidance Settings Mode will automatically exit if there is no further ac-tivity within 8 seconds.
Note: You must press the M button within 8 seconds of selecting the new sensitivity level to save the new setting or the unit will revert to the previous setting level.
Collision Avoidance Sensitivity Levels: 0∼5
0: Turn Off Collision Avoidance.
1∼5: Sensitivity Setting – Level 1 is the lowest sensitivity and the le-vel 5 is the highest sensitivity.

TROUBLESHOOTING

The table shows error messages that can appear on the display panel.

Error Message
| Description
---|---
The r St message is displayed on the display when the reset is in progress.
| The table was overloaded. Check that the load on the table is not greater than its capacity. Disconnect and reconnect the power cord, and perform a Reset. If the message persists, contact customer support.
Please Note: The table features an overload protection setting, which is activated automatically. The table will descend about 30mm and the display will show the actual table height.
| The system is overheated and must cool down.
The overheating protection feature is turned on after 2 minutes when the HOT message appears on the display. You’ll be able to control the table again normally after another 20 minutes.
Please Note: Never unplug the power cord when the overheating protection feature is activated.
Usually there is nothing to worry about. The overheated system can occur due to many reasons, such as due to the surroun­ding temperature, table load or high activity with the control panel.
If the error message continues to show, contact customer support.
| An error has occurred due to the motor connection. Check the cable connected to the motor and the control panel. Unplug and plug back the cable and perform a system Reset.
| The table was overloaded. Check that the load on the table is not greater than its capacity. Disconnect and reconnect the power cord, and perform a Reset. If the message persists, contact customer support.
OR
An overvoltage has occurred. It is necessary to replace the power adapter, contact customer support.

Please Note : Never disconnect the power cord when the overheating protection feature i s activated.

This product meets all of the related basic EU regulation require- ments. The EU declaration of conformity i s available on www.al- zashop.com/DoC.
This product sold i n the European Union meet the requirements of Directive 2011/65/EU on the restriction of the use of certain hazard- ous substances in electrical and electronic equipment (RoHS). The use of the WEEE Symbol indicates that this product should not be treated as household waste. By ensuring this product isdis – posed of correctly, you will help protect the environment. For more detailed information about the recycling of this product, please contact your local authority, your household waste disposal service provider, or the shop where you purchased the item. “For indoor use only” symbol indicates that the product i s not in- tended for outdoor use.

R20220405AlzaErgo -logowww.alzaergo.com
Co. Reg . No. 27082440
Alza.cz a.s., Jankovcova 1522/53, 170 00 Prague 7, Czech Republic
© 2022 Alza.cz a.s. All Rights Reserved.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals