EVbee E100007 FlexCharger EV Mobile Charger User Manual
- June 9, 2024
- EVbee
Table of Contents
EVbee E100007 FlexCharger EV Mobile Charger
Product Overview
How to use
Start charging
❶ Connect the Schake plug to the wall socket.
❷ Set the charging current and the timer
❸ Connect the car plug to the car.
❹ Lock your car
Stop charging
❺ Unlock your car
❻ Disconnect the Schake plug from the wall socket
❼ Disconnect the car plug from the car.
❽ Put on the dust cover for the car plug and store the charger away
Usage tips
- Make sure to use considerable force when plugging in the charger until the pins are well connected to the socket or the car
- If the neutral wire of the wall socket is wrongly positioned, the charger might not work.
- The car needs to be unlocked and powered off to start the charging process.
- The car plug must be plugged directly into a Type 2 socket.
Warning
- Always check the charger for damage and contamination before use.
- Never use a damaged charger, damaged plugs, or any damaged electrical infrastructure.
- Never use contacts that are dirty or wet.
- Do not use the charger with an extension cable or an adapter.
- Do not disconnect the plugs during the charging process.
- If the plugs emit smoke or begin to melt, never touch the charger. If possible, stop the charging process. In any event, disconnect the power supply from the charger.
- Mind the risk of electrical shock or burn.
- The product does not contain any user-serviceable parts.
- Keep the charger out of the reach of children.
- Please refer to the user manual of the car that you want to charge with this product.
- Use the product only in protected outdoor areas.
- Protect the product from moisture, liquids and sunlight.
- Modifications or changes to the product are life-threatening and lead to the immediate exclusion of the warranty.
- Connect the product only to an error-free, properly grounded and suitable infrastructure (mains socket 16A). If in doubt, consult a specialist.
Warranty
Warranty period is 3 years. Please visit evbee.com for full details.
Display Values
Light Indicators
Status
| Light 1 (Green)| light 2 (Green)| Light 3 (Green)|
Light 4 (Red)
---|---|---|---|---
Connected
| ✓| X| X| X
Charging| The three lights flash in sequence.|
X
Charging Completed
| ✓| X| X| X
Connection Error| X| X| X|
1 flash followed by 1.5 seconds pause
Overvoltage
| X| X| X| 2 flashes followed by1.5 seconds pause
Overcurrent| X| X| X|
3 flashes followed by1.5 seconds pause
Under voltage
| X| X| X| 4 flashes followed by1.5 seconds pause
Undercurrent| X| X| X|
5 flashes followed by1.5seconds pause
Relay Failure
| X| X| X| 6 flashes followed by 1.5 seconds pause
Overheated PCB| X| X| X|
7 flashes followed by 1.5seconds pause
leakage Current
| X| X| X| 8 flashes followed by 1.5 seconds pause
leakage Detection Failure| l(| X| X|
10 flashes followed by 1.5seconds pause
Communication Failure
| X| X| X| 11 flashes followed by 1.5secondspause
Ground Fauh| X| X| X|
✓
Unknown Failure
| X| X| X|
1 flash followed by 4 seconds pause
Important information for the correct disposal of the product in accordance with Directive 2012/19/EC. At the end of its useful life, the product must be taken to a collection center for special and differentiated disposal or to a distributor that provides this service.