HUMAN CARE 53211 Svea Trolley Walker User Manual
- June 9, 2024
- HUMAN CARE
Table of Contents
HUMAN CARE 53211 Svea Trolley Walker
Important
You must read the user manual for your device prior to usage. Keep this booklet and information handy for future use.
Symbols
- WARNING symbol indicates a potentially hazardous situation which, if not avoided, could result in serious injury to the user or damage to property and/or the device itself.
- INFORMATION symbol indicates recommendations and information for proper, trouble-free usage.
- WEIGHT CAPACITY symbol indicates maximum user weight for the product. Do not exceed this weight in any circumstance.
- CE MARKING symbol indicates product meets requirements of EU Directive 93/42/EEC (MDD) and/or EU Regulation 2017/745 (MDR).
- RECYCLE according to local regulations.
- MEDICAL DEVICE symbol indicates that the product is a medical device according to the definition of medical device in EU Directive 93/42/ EEC (MDD) and/or EU Regulation 2017/745 (MDR).
- READ INSTRUCTIONS and ensure you fully understand them before using this product.
Product modification is not permitted. Before use, always check that the sling is not damaged or worn.
Human Care’s products are continuously being developed and updated to provide our customers with the highest quality. We reserve the right to make design changes without prior notice. Always make sure that you have the most recent version of the manual which is available for download from our website at www.humancaregroup.com. Contact your local distributor if you have any questions about the product and its use.
Notice to user/patient in case of serious incident
Any serious incident that has occurred in relation to the product, should be
reported to the local contact, who reports to the manufacturer, and the
competent authority of the country in which the user/patient is established.
Compliances and Standards
- Human Care is an ISO 13485:2016 certified Swedish medical device company. The Quality Management System is in compliance with US 21 CFR part 820.
- The product is CE marked in accordance with EU Directive 93/42/EEC (MDD) and/or EU Regulation 2017/745 (MDR), as class I medical device.
- The CE mark is on the product.
- This product has been tested in accordance with ISO 11199-2:2005.
About our products
On delivery
Check the following before using your new product:
- Check that no damage has occurred during transport (if this is the case, please immediately inform the delivery agent).
- Check that the number and type (s) of products detailed on the delivery certificate agree with the goods delivered.
- Check that the delivery is of the desired model and type of product.
Please contact us immediately in case of any delivery problem.
Return or refund
If any product has to be returned for any reason, please contact us to obtain
a claim number and advice on how to proceed. The goods should be returned in
complete and undamaged condition in their original packaging. The following
information should accompany any product on its return. The product’s
identification number, delivery date, the date the user took possession of the
aid, the date of the product’s last service, the person whom we should contact
about the fault, whether it be the user or another, and the nature of the
fault. Human Care HC AB reserves the right to inspect the returned product. If
no fault can be found, the item will be returned to the user. Transport costs
may then be chargeable.
Product lifetime
The product´s expected lifetime is seven (7) years, if the product is used as
intended and maintained according to the manufacturer´s instructions,
depending on the intensity of use and maximum load applied during use. If the
product label is no longer legible, the product should be discarded.
Additional Warnings
- Ensure that all bolts are securely fastened before using the rollator!
- Brakes must be in the parked/locked position before sitting on the rollator!
- DO NOT adjust brake tension until wheels lose molding sheen!
- DO NOT hang anything on backstrap or it may break!
Safety
In the instruction manual, three ways of drawing special attention are used.
These ways are highlighted in the following manner.
- Attention! Risk of personal injury or mechanical fault.
- Important! Risk of mechanical damage or fault.
- Note! Important information to ease handling.
Recycling of products
When recycling, the product’s chassis is separated from other parts. At
separation, the parts can be sorted according to material after unscrewing and
dismantling rivets and other connections. The different parts should be
separated into metal, plastic or combined materials. The products consist
mainly of steel pipe and other metal components. Examples of parts which
consist of combined materials, are the plastic front forks (built up in
several layers), wheels and other components, which consist of a composite of
materials.
Note! Different authorities/recycling companies handle recycled materials in different ways. It is thus fitting when in any doubt over the best way to proceed when recycling, to contact the relevant governing body.
Environment friendliness
Human Care aides are manufactured so as to have as little effect on the
environment as possible during their lifecycles. This allows for the expired
product to be dismantled and for its parts to be recycled. Products with
lengthy lifecycles safeguard our sensitive environment and are thus more
environmentally friendly.
Human Care HC AB is a part of REPA. REPA – A countywide system for recycling
of packaging.
Intended use
Svea is a stable trolley walker which is suitable for use both indoors and outdoors. The trolley walker is available in two heights and two widths.
Technical data
Rollator Art no.| Min.| Max.| Width| Length| Wheel
size| Weight (kg)| Standard (kg)
---|---|---|---|---|---|---|---
53211 Low| 820| 1070| 590| 850| 200×40| 14,9| 150
53221 High| 1010| 1260| 590| 850| 200×40| 15,1| 150
53411 Low| 820| 1070| 680| 850| 200×40| 15,1| 150
53421 High| 1010| 1260| 680| 850| 200×40| 15,3| 150
Accessories
Accessories | Model | Art. no. |
---|---|---|
One-hand break | 10653 |
See respective assembly instruction.
User guide
- Read all warnings and instructions carefully before using the rollator.
- Ensure that the rollator is properly unfolded before use.
- The rollator may only be used as a support for walking.
- Never stand on the rollator.
- Do not use the product on stairs or escalators.
- Be extra careful when using the rollator on slopes or uneven surfaces.
- Never sit on the rollator and roll yourself forward with your feet.
- Distribute weight evenly to prevent the rollator from tipping when you sit on it.
- Always set the parking brake before using the rollator for support while sitting down or getting up.
- Do not place anything on a folded up rollator when it is in storage or being transported as this may cause damage to it.
- Do not store the rollator close to a heat source as this could cause damage to some details.
- Be careful when you handle the rollator if it has been exposed to abnormally high or low temperatures to avoid injuries.
- Do not store the rollator outdoors.
- Save the user instructions for future use.
Adjustment of height
The height of the table is handled steplessly by a gas spring. Push handle
upwards and adjust desired height. When handle is released the gas spring
automatically locks.
Adjustment of driving handle
The driving handle can be adjusted to the position by loosing the wing-nuts
under the table.
Brake adjustment
For desirable braking strenght, adjust the brake wire by screwing outwards.
Brake
Pull the brake handle upwards to brake.
Parking brake
Push the brake handle downwards for parking position.
Cleaning and service
- Important! When changing parts of the rollator, use only Human Care parts to ensure continued CE validation.
- Important! Do not alter the rollator yourself.
- Important! Check the rollator regularly to ensure its continued safety to the user.
Regular checks should be carried out as recommended by the instructions
detailed in maintenance manual 99202.
For more information on servicing, reconditioning, spare parts and
accessories, see Human Care’s website:
www.humancaregroup.com or contact us at the
address, phone number or e-mail address according to back page.
Warranty
The Human Care HC AB warranty covers defects in material and manufacture of
the walking aid. Wear on wheels, brake parts and handles are not included.
Finish damages which have occurred after delivery are not covered. The
warranty presumes that the product has been used in the intended way and that
it has been regularly reconditioned in accordance with our reconditioning
instructions. The ID number of the product must also be identifiable.
Furthermore, the product must not have been modified or customized by any
party other than Human Care HC AB. The warranty period is one (1) year or
according to agreement.
For complaints, please contact us for instructions on how to proceed.
For complaints, the following information should be indicated: product ID
number; the date of the last reconditioning; the name of the consignor
contact; a description of the fault.
HUMAN CARE SWEDEN (HQ)
Årstaängsvägen 21B
117 43 Stockholm
Phone: +46 8 665 35 00
Fax: +46 8 665 35 10
Email: info.se@humancaregroup.com
HUMAN CARE CANADA
10-155 Colonnade Road
Ottawa, ON K2E 7K1
Phone: +1 613 723 6734
Fax: +1 613 723 1058
Email: info.ca@humancaregroup.com
HUMAN CARE UNITED STATES
8006 Cameron Street, Suite K
Austin, TX 78754 USA
Phone: +1 512 476 7199
Fax: +1 512 476 7190
Email: info.us@humancaregroup.com
HUMAN CARE NEDERLAND
Elspeterweg 124
8076 PA Vierhouten
Phone: +31 577 412 171
Fax: +31 577 412 170
Email: info.nl@humancaregroup.com
www.humancaregroup.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>