Trust ZCO-900 Zigbee Carbon Monoxide Detector User Manual

June 9, 2024
Trust

Trust ZCO-900 Zigbee Carbon Monoxide Detector LOGO

Trust ZCO-900 Zigbee Carbon Monoxide Detector

Trust ZCO-900 Zigbee Carbon Monoxide Detector PRODUCT

COMPATIBILITY

This Carbon Monoxide detector works with the Smart Bridge and the ICS-2000 to give additional functionality like receiving push notifications when Carbon Monoxide is detected.
NOTE: For receiving push notifications, a fully working internet connection is required. Replace the detector max 10 years after production date. The production date can be found on the battery label inside the sensor

PLACING CARBON MONOXIDE DETECTOR

  •  The detector must be placed at a horizontal distance between 1 and 3 meters from the CO source (boiler, geyser, central heating system, gas heater).
  •  Ensure that the detector is placed centrally in the room.
  • Place the detector at least 30 centimeters from surrounding walls.
  •  The detector must be placed at breathing level in the bedroom (this is the height at which you sleep)
  •  Always comply with local legislation regarding installation in buildings.
  •  Do not place the detector in or under a cabinet
  • Do not place the detector where it is obstructed by curtains or furniture.
  •  Do not place the detector in a damp room.
  •  Do not place the detector next to existing air inlets or outlets or other objects on the ceiling.

TESTING AND USAGE

  •  Always test the CO detector with the test mode after installation and then once a week. Replace the CO alarm immediately if the test fails.
  • Replace the battery immediately when the CO alarm indicates that the battery is low. (up to 3 years of battery life) (See LED function table)
  •  Never use water, cleaning agents or solvents to clean the CO detector as this may damage the device.
  •  If the CO detector is damaged, replace it immediately.
  •  The CO alarm will not warn residents with a hearing impairment. It is recommended to install special CO detectors to warn people with hearing difficulties.
  •  Use only a CR123A 3.0V lithium battery. Other batteries can cause unreliable operation.
  •  When the battery is removed, the CO alarm will no longer work.
  •  Press the test button to check the operation after replacing the battery.

If you suspect that there is a CO leak, open the doors and windows to ventilate. If possible, switch off all fuel-driven devices, leave the premises and call professional help.
Check www.trust.com/71260 for the latest instructions

REMOVE BATTERY PULL STRIP

  •  Remove the detector from the mounting bracket by twisting it.
  •  Pull the battery pull strip out of the CO detector. After removing the battery pull strip, the CO detector will beep and will warm up (can take up to 2 min). (See LED function table)Trust ZCO-900 Zigbee Carbon Monoxide Detector 01

INDICATORS
The CO detector contains an LED indicator light to indicate the status. Look below for the meaning of the different LED indications.Trust ZCO-900 Zigbee
Carbon Monoxide Detector 02

LED FUNCTION TABLE

Warming up LED light flashes red, green and yellow
Connected successfully LED will light up for 3 sec (The App will also

indicate when the connection is successful)
Detector reset| LED will flash 6x
Test| LED light flashes 4x fast red and the detector beeps 4x
Alarm| LED light flashes red and the detector beeps 4x (85 db) every 5 seconds. The detector stops as soon as no more CO is detected
Operation of CO detector| The LED light flashes 1x green every 30 seconds to indicate that the CO alarm is working properly
Battery low indication| LED light flashes 1x yellow and the detector beeps every 30 seconds
---|---
Error| LED light flashes 2x yellow and the detector beeps 1x long and 1x short every 30 seconds. Remove the battery and insert it again.
Replace detector| LED light flashes 2x yellow and gives 1 long and 1 short beep every 30 seconds. The detector needs to be replaced

DOWNLOAD APP
First download and install the KlikAanKlikUit App from the Google Playstore or App store to connect the CO detector to an ICS-2000 or Smart Bridge bridge.Trust ZCO-900 Zigbee Carbon Monoxide Detector
03

CONNECT DETECTOR
  • In the App, select a room, press the + button and choose Trust Zigbee line/Carbon Monoxide detector and follow the instructions. For manual set up of push-notifications go to the rules tab, press the + button and select notification wizard.Trust ZCO-900 Zigbee Carbon Monoxide Detector 04
 MOUNT THE DETECTOR
  •  Mount the bracket of the  detector on a flat surface on the ceiling and secure it with the included screws.
  1. Place the detector on the mounting bracket.Trust ZCO-900 Zigbee Carbon Monoxide Detector 05
  2.  Secure the detector by twisting it on the bracket to lock it.Trust ZCO-900 Zigbee Carbon Monoxide Detector 06

TEST MODE
Activate the test mode of the detector to check the operation by pressing the Test button. The LED will flash fast and the detector will sound.Trust
ZCO-900 Zigbee Carbon Monoxide Detector 07
Trust ZCO-900 Zigbee Carbon Monoxide Detector 08

RESET DETECTOR AND ACTIVATE CONNECT MODE
Warning: This step will disconnect the detector from the Smart Bridge or the ICS-2000. To reset the detector press the button in the hole at the side for approximately 5 sec with the included pin. The LED will flash 6x to confirm the reset.
Activate connect mode: After resetting the detector you can activate the connect mode by pressing the button in the hole on the side for approx. 2 sec. The LED will flash fast for 1 minute to indicate the connection mode.

REPLACE BATTERY

  • Open the battery  compartment by removing the detector from the bracket.
  •  Remove the empty battery and insert a new 3V CR123A lithium battery in the compartment. Note the positive and negative polarity.
  • Lock the detector back on the bracket. Test if the battery is placed correctly by activating the test mode. (See step 6).Trust ZCO-900 Zigbee Carbon Monoxide Detector 09

DISCLAIMER
Trust cannot be held responsible or liable for injuries caused by a carbon monoxide leak.

TECHNICAL SPECIFICATIONS

Zigbee 2400-2483.5 MHz; 9 dBm
Battery CR123A lithium battery, 3V (included)
Size HxWxL: 60 x 60 x 49.2 mm

www.trust.com/zigbee

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals