COMPATIBILITY
This Carbon Monoxide detector works with the Smart Bridge and the ICS-2000 to
give additional functionality like receiving push notifications when Carbon
Monoxide is detected.
NOTE: For receiving push notifications, a fully working internet
connection is required. Replace the detector max 10 years after production
date. The production date can be found on the battery label inside the sensor
PLACING CARBON MONOXIDE DETECTOR
- The detector must be placed at a horizontal distance between 1 and 3 meters from the CO source (boiler, geyser, central heating system, gas heater).
- Ensure that the detector is placed centrally in the room.
- Place the detector at least 30 centimeters from surrounding walls.
- The detector must be placed at breathing level in the bedroom (this is the height at which you sleep)
- Always comply with local legislation regarding installation in buildings.
- Do not place the detector in or under a cabinet
- Do not place the detector where it is obstructed by curtains or furniture.
- Do not place the detector in a damp room.
- Do not place the detector next to existing air inlets or outlets or other objects on the ceiling.
TESTING AND USAGE
- Always test the CO detector with the test mode after installation and then once a week. Replace the CO alarm immediately if the test fails.
- Replace the battery immediately when the CO alarm indicates that the battery is low. (up to 3 years of battery life) (See LED function table)
- Never use water, cleaning agents or solvents to clean the CO detector as this may damage the device.
- If the CO detector is damaged, replace it immediately.
- The CO alarm will not warn residents with a hearing impairment. It is recommended to install special CO detectors to warn people with hearing difficulties.
- Use only a CR123A 3.0V lithium battery. Other batteries can cause unreliable operation.
- When the battery is removed, the CO alarm will no longer work.
- Press the test button to check the operation after replacing the battery.
If you suspect that there is a CO leak, open the doors and windows to
ventilate. If possible, switch off all fuel-driven devices, leave the premises
and call professional help.
Check www.trust.com/71260 for the latest instructions
REMOVE BATTERY PULL STRIP
- Remove the detector from the mounting bracket by twisting it.
- Pull the battery pull strip out of the CO detector. After removing the battery pull strip, the CO detector will beep and will warm up (can take up to 2 min). (See LED function table)
INDICATORS
The CO detector contains an LED indicator light to indicate the status. Look
below for the meaning of the different LED indications.
LED FUNCTION TABLE
Warming up | LED light flashes red, green and yellow |
---|---|
Connected successfully | LED will light up for 3 sec (The App will also |
indicate when the connection is successful)
Detector reset| LED will flash 6x
Test| LED light flashes 4x fast red and the detector beeps 4x
Alarm| LED light flashes red and the detector beeps 4x (85 db) every 5
seconds. The detector stops as soon as no more CO is detected
Operation of CO detector| The LED light flashes 1x green every 30 seconds to
indicate that the CO alarm is working properly
Battery low indication| LED light flashes 1x yellow and the detector beeps
every 30 seconds
---|---
Error| LED light flashes 2x yellow and the detector beeps 1x long and 1x short
every 30 seconds. Remove the battery and insert it again.
Replace detector| LED light flashes 2x yellow and gives 1 long and 1 short
beep every 30 seconds. The detector needs to be replaced
DOWNLOAD APP
First download and install the KlikAanKlikUit App from the Google Playstore or
App store to connect the CO detector to an ICS-2000 or Smart Bridge
bridge.
CONNECT DETECTOR
- In the App, select a room, press the + button and choose Trust Zigbee line/Carbon Monoxide detector and follow the instructions. For manual set up of push-notifications go to the rules tab, press the + button and select notification wizard.
MOUNT THE DETECTOR
- Mount the bracket of the detector on a flat surface on the ceiling and secure it with the included screws.
- Place the detector on the mounting bracket.
- Secure the detector by twisting it on the bracket to lock it.
TEST MODE
Activate the test mode of the detector to check the operation by pressing
the Test button. The LED will flash fast and the detector will sound.
RESET DETECTOR AND ACTIVATE CONNECT MODE
Warning: This step will disconnect the detector from the Smart Bridge or
the ICS-2000. To reset the detector press the button in the hole at the side
for approximately 5 sec with the included pin. The LED will flash 6x to
confirm the reset.
Activate connect mode: After resetting the detector you can activate the
connect mode by pressing the button in the hole on the side for approx. 2 sec.
The LED will flash fast for 1 minute to indicate the connection mode.
REPLACE BATTERY
- Open the battery compartment by removing the detector from the bracket.
- Remove the empty battery and insert a new 3V CR123A lithium battery in the compartment. Note the positive and negative polarity.
- Lock the detector back on the bracket. Test if the battery is placed correctly by activating the test mode. (See step 6).
DISCLAIMER
Trust cannot be held responsible or liable for injuries caused by a carbon
monoxide leak.
TECHNICAL SPECIFICATIONS
Zigbee | 2400-2483.5 MHz; 9 dBm |
---|---|
Battery | CR123A lithium battery, 3V (included) |
Size | HxWxL: 60 x 60 x 49.2 mm |