SUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign Installation Guide

June 9, 2024
Sunco Lighting

EX_2HFL-RED-6PK EXIT LED Sign
Installation GuideSUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED
Sign The Brighter Choice

EXIT LED SIGN

Install Guide and Manual

CEILING MOUNT

  1. Disconnect AC power, make sure the battery is unplugged before servicing
    •If you are replacing an existing halogen fixture, allow the fixture to cool away from flammable materials.

  2. Unsnap faceplate to open (see figure)
    •For dual-sided EXIT sign, remove backplate and replace with extra faceplate (included)SUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig
2

  3. Unsnap canopy hole cover on the top of fixtureSUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig 3

  4. Feed lead wires through a hole on the top of the fixture, ensure wires are secured into wire guides

  5. Connect leads to AC input leads in the Junction Box. Black wire for 120V, Red/Orange wire for 277V
    •Cap off unused wires
    •Feed excess wire into a junction box

  6. Attach canopy to j-box using bracket and screws (included), wires will go through the center hole in the canopy
    •Snap housing to canopySUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig
6

  7. Connect the battery (see figure)SUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig 7

  8. Snap-in arrows on EXIT faceplate as required

  9. Secure faceplate to housing
    SUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig 8

  10. Test after 24 hours of charging

CEILING  MOUNT DIAGRAM

SUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig 9 IMPORTANT
The battery in this unit may not be fully charged. After electricity is connected to the unit, let the battery charge for at least 24 hours before performing any tests. To test, process “TEST” button and sign should illuminate. Only use LED specified for the fixture when re-lamping.
EQUIPMENT: Flat head Philips screwdriver, drill recommended.SUNCO
LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig 10

WALL MOUNT

  1. Disconnect AC power, make sure the battery is unplugged before servicing
    •If you are replacing an existing halogen fixture, allowing the fixture to cool away from flammable materials.

  2. Unsnap faceplate to open (see figure)
    SUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig 2

  3. Drill holes for knockouts on the backplate that correspond to junction box holes

  4. Feed lead wires through a hole in the center of the backplate, ensure wires are secured into wire guidesSUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig 12

  5. Connect leads to AC input leads in the Junction Box. Black wire for 120V, Red/Orange wire for 277V
    •Cap off unused wires
    •Feed excess wire into a junction box

  6. Fasten backplate to the junction box
    •Snap housing to canopy

  7. Connect the battery (see figure)
    •Snap housing on to the backplate (first top then bottom)SUNCO LIGHTING
EX_2HFL-RED-6PK EXIT LED Sign - Fig 7

  8. Snap-in arrows on EXIT faceplate as required

  9. Secure faceplate to housing
    SUNCO LIGHTING EX_2HFL-RED-6PK EXIT LED Sign - Fig 15

  10. Test after 24 hours of charging

WARNING
When using electrical equipment, basic safety precautions should always be followed. Consult local building codes for approved wiring and installation.

  • Do not use outdoors
  • Do not mount near gas or electric heaters
  • Cap unused wires with wire nuts
  • Use caution when servicing batteries
  • Equipment should be mounted securely in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel.

SPECIFICATIONS

Charging time 220 lm
The AC voltage 5500 ± 500K
Luminous flux 360°
Color temperature 90min
Swiveling flood lights 24h
Backup battery 120/277V

Read User Manual Online (PDF format)