Citimarine Store 2 Station Marine AC Pump Relay in Metal Box User Manual

June 9, 2024
Citimarine Store

Citimarine Store 2 Station Marine AC Pump Relay in Metal Box

Description

Multi-station pump relay with electrically isolated inputs for use with common source water HVAC systems. The relay will turn on the pump when activated by any of the two or six inputs

Specifications

  • Continious AC Current 18 Amps
  • Peak AC Current 35 Amps
  • AC Line Input 90 to 240 VAC
  • Trigger Signal 90 to 240 VAC
  • Humidity 95% non-condensing
  • Temperature Range -20 ºF to 140 ºF (28.9 to 60 ºC)
  • Board Dimensions 4.45” x 4.125” (113 mm x 105 mm)
  • Board Mounting Dimensions 3.525” x 3.5” mounting template; 0.15” hole (89.5 mm x 88.9 mm, 3.81mm hole)
  • Housing Dimensions 8.25” x 6.25” x 2.67” (209.6mm x 158.75mm x 67.8mm)

Product Ordering

  • ASY-110-X01 Two station with enclosure
  • SUB-111-X1V Two station board only
  • ASY-111-X01 Six station with enclosure
  • SUB 111-X2V Six station board only

Typical Applications Wiring

Using External Contactors

Use an external contactor for pumps exceeding the specifications above or for three phase pumps. Cut JMPI only when using a contactor.

Installation Warning

This board must be mounted using only the four corner mounting holes in the circuit board. Some electrical enclosures may have additional mounting points that can contact the bottom of the circuit board. These mounting points must be removed prior to board replacement. Failure to follow this warning can result in irreparable damage to the circuit board that will void the warranty. Please contact CTM Marine with any questions regarding this warning.  www .ctm-marine.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals