KIBIY MS-672 Cordless LED Bald Head Shaver User Manual

June 9, 2024
KIBIY

KIBIY logo MS-672 Cordless LED Bald Head Shaver
User Manual

MS-672 Cordless LED Bald Head Shaver

Thank you for purchasing this product. To ensure proper use and trouble free opera- lion, please read this manual carefully and store it in a safe place for future reference.

Safety Instructions

  1. Do not use salt water, hot water above 113°F/45°C , thinners, gasoline, alcohol to clean the electric shaver.
  2. It is normal for the device to heat up slightly during use or charging.
  3. Please check if the shaver head is damaged or deformed before shaving to protect your skin from hurt.
  4. Do not immerse the appliance into the water for a long time.
  5. Do not charge the appliance with a damaged cable.
  6. Do not plug or unplug the appliance with wet hands.
  7. Do not store the electric shaver in direct sunlight or near other sources of heat.
  8. Cover the shaver head with the protection cover to prevent it from damage.

KIBIY MS 672 Cordless LED Bald Head Shaver - Figure 1

Components

  1. ON/OFF Button
  2. LED Display
  3. Rotary Shaver Head
  4. Facial Cleaning Brush
  5. Nose Trimmer
  6. Hair Trimmer
  7. Massage Head
  8. Protection Cover
  9. Hair Trimrner Guide Comb x3 (3/517rnm)
  10. Type -C USB Cable
  11. Cleaning Brush

Specifications

  • Waterproofing Grade: IPX7
  • Rated Power: 5W
  • Rated Voltage: 3.7V 800mAH
  • Input: 5V 1A(USB)
  • Charging Time: 90 Mins
  • Running Time: 90 Mins

Operation Instruction

KIBIY MS 672 Cordless LED Bald Head Shaver - Figure 2Travel Lock Long press the ON/OFF button for 3 seconds to lock or unlock the device.
Stall Protection: The electric shaver will auto power off and “ ” will light on in the following:

  1. Incorrect shaving head installation.
  2. Shaving head was full of hair.
  3. The motor can not drive the shaving head.
    Clean the shaving head before use.

Cleaning Reminder: Clean the electric shaver when the faucet symbol flashes.

  1. The LED will display that the available time is 90 mins, it means fully charged.
  2. The LED will display the available time when power on.
  3. The LED will display the”time of use” when power off.

How to Use

How to change shavers
KIBIY MS 672 Cordless LED Bald Head Shaver - Figure 4

  1. Gently pull the shaver
  2. Match the lock slot. out and do not twist it.
  3. Insert the shaver into the body.

How to Attach a Comb
KIBIY MS 672 Cordless LED Bald Head Shaver - Figure 5

  1. Hold the comb upwards.
  2. Slide down the comb along the clipper blade till you hear a “snap” sound.

Hair Trimming

  1. Comb and dry hair
  2. Use the hair clipper with the desired guide comb to trim long hair.
  3. If with long hair for head shaving, please use hair clipper with guide comb to cut hair to 3mm, then only use hair clipper to cut hair to 1.5mm, then switch to the rotary shaver to shave closely for a better bald look.
  4. Try to use the rotary shaver at different angles for better shaving performance.
  5. Clean the rotary shaver and cover the shaver head with a protection cover after use.

Shave Beard
KIBIY MS 672 Cordless LED Bald Head Shaver - Figure 6

  1. Check and clean the shaver head.
  2. Press the ON/OFF button to turn on the electric shaver.
  3. Gently move the electric shaver against the growth direction of the beard.

Warm Tip: It’s suggested to use shaving cream for a smooth and close shave.
Vibrissa Trimming

  1. Clean the nasal cavity.
  2. Switch on the device, insert the vibrissa trimmer tip into the nasal cavity, and turn the tip to remove the vibrissa.
    Note: Do not insert the tip exceed 0.2 inches/0.5 cm to prevent the nose from injury.

Ear hair Trimming

  1. Clean the external auditory canal.
  2. Insert the vibrissa trimmer tip into the external auditory canal, and turn the tip to remove the protruding hair.
    Note: Do not trimming too much to prevent the nose from injury.

Maintenance

Charging

  1. Charging the shaver when the indicator flashes.
  2. The number on the display flashes to show that the device is charging.
  3. Charging the shaver with a 5V adapter mobile phone charger, USB port of cars, computers, and others.
  4. Charging and storing the shaver within 59°F/15°C and 95°F/35°C .
  5. Do not charge the shaver for too long.
  6. Unplug the electric shaver after fully charged.

Cleaning

  1. Use the brush to clean the remaining hair on the shaving heads.
  2. Clean the shaver head with water or the equipped cleaning brush after use.
    Note: Do not wipe the shaving head part with tissue or cloth, which may cause damage.

How to clean the rotary shaver
Efficient cleaning tips:
KIBIY MS 672 Cordless LED Bald Head Shaver - Figure 7

  1. Turn on the shaver.
  2. Submerge the shaver head into the water when it is on.

Note:

  1. Please do not clean the machine under hot water exceeding 45°C (113°F).
  2. If there is too much hair in the head attachment of the device, please clean it in the way of the following figure (Figure 1-3).

KIBIY MS 672 Cordless LED Bald Head Shaver - Figure 8

  1. Hold the 2 sides blades to open it slightly.
  2. Pinch the groove of the edge of the blade and take it apart.
  3. Rotate the middle blade with an angle of 15 degrees counterclockwise.

Troubleshooting

Problem Cause Solution
Can’t be turned on Can’t be charged. 1. Use the adapter specified (5V,1A)

and ensure to charge it for 90 Mins for full charging.
2. Charge it at least once a month.
3. Keep and use it within a temperature range of 15-35°C (59-95°F).
Use hot water to rinse resulting in water permeating the product.| The water temperature for cleaning should not exceed 45°C (1-13°F ).
The shaver hasn’t been used for a long time.| Tap the product or install the brush head accessories and twist the brush head artificially for a circle before turning it on.
The lock button is locked.| Long press the button for 3 seconds to unlock.
Switches or other components such as battery or motor were damaged.| Contact Customer Service.
Suddenly stop working after a short time| Low temperature| Keep and use it in a temperature range of 15-35 °C (59-95 °F).
Insufficient charging time| Use the adapter specified and ensure to charge it for 90 Mins for full charging.
Didn’t clean the shaving residues in time.| Remove them promptly after shaving.
The broken battery result in rotation failure.| Contact Customer Service Team
Can’t shave cleanly or come witn skin rash| Too long hair leads to pulling| Use hair clipper with limit comb to cut hair to 3mm, then only use hair clipper to cut hair to 1.5mm, finally use shaver head.
The head shaver becomes dull after long time use| Replace the shaver head once every six months.
Incorrect use of accessories or sensitive skin| 1. Use hair clipper with limit comb to cut hair to 3mm,then only use hair clipper to cut hair to 1.5mm, finally use shaver head.
2. Use with post-shave healing balm to calm the skin.

Warranty
The product supports a 1-year warranty from the date of purchase. This warranty does not apply to products which have been lost, altered, broken, or damaged by misuse or failure to follow the instruction provided with the product. Never try to repair the product by yourself. Please contact our after-sales team, we are free to help you solve the problems anytime.
Contact Us
For any inquiries concerning our products, please feel free to contact us via
US:kibiy01@outlook.com
UK:customerservices-uk01@outlook.com

Made in ChinaKIBIY MS 672 Cordless LED Bald Head Shaver - icon
2

Documents / Resources

| KIBIY MS-672 Cordless LED Bald Head Shaver [pdf] User Manual
MS-672, Cordless LED Bald Head Shaver, LED Bald Head Shaver, Cordless Head Shaver, Head Shaver, Shaver
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals