This product is only suitable for well insulated rooms or occasional use.
- The Palma 2.0 is not designed for use by persons (including children) who have limited physical, sensory or mental capabilities. It must not be used by persons with insufficient experience or knowledge of handling this type of product except where they are monitored or instructed by an experienced and knowledgeable person who is responsible for their safety.
- After unpacking and before initial operation, make sure the Palma 2.0 and all the relevant accessories are in good working order. If transport damage is discovered, STOP and contact the distributor or manufacturer immediately.
- Consult a specialist if you have any doubts or questions regarding the functioning, safety or connection of the Palma 2.0.
- This manual is an important part of the Palma 2.0 and must be kept in a safe place. If the Palma 2.0 is sold, loaned or otherwise passed on to a third party, then this manual must be passed along to ensure safe operation.
- Any incorrect or unauthorized repair will void the manufacturer’s warranty.
Introduction
This manual is intended for the Palma 2.0 RAW and Palma 2.0. The Palma 2.0 RAW
consists of an air circulation heater. The Palma 2.0 consists of the air
circulation heater and a wet room thermostat Thermol.The electric air
circulation heater Palma 2.0 and Palma 2.0 RAW serves to control the
temperature of greenhouses and conservatories.
Read and observe the directions in these instructions and the general safety
and hazard notes carefully before installation. Keep this leaflet in a safe
place for future reference. If you doubt the safety of this device please seek
advice from a specialist. If using the device in a greenhouse please ensure
that the electrical connections are installed by qualified staff.
Technical data
1.1 Scope of delivery
Palma 2.0-Digital:
- Air circulation heater Palma 2.0
- 1 Digital-Termostat ”Thermo 2”
Palma 2.0
Device type| Air circulation heater
Power supply| 230 V/50-60 Hz
Maximum performance| 2025 W
Maximum power consumption| 9,0 A
Control range| 0 bis 85 °C
Controller tolerance:| ± 5 °C
Input| < 1,5 W
Protection class| I
Protective system| IP X4
Abmessungen| 280 x 195 x 315 mm
Palma 2.0- Manuell:
- Air circulation heater Palma 2.0
Thermo 2
Device type| Digital-Thermostat
Power supply| 230 V/50-60 Hz
Max. breaking capacity| 3000 W
Max. switching current| 16 A
Control range:| -50 bis +99 °C
Distinction rate| ± 1 °C
Input| < 1,5 W
Protection class| II
Protective system| IP X4
Sensor length:| approx. 2,5 m
1.2 Main component parts
Palma 2.0-Digital (1)
”Thermo 2” (2) (optional)
Preventive measures and safety instructions
2.1 Warning! A warning indicates the risk of damage to the user or the
product if the user does not carry out the procedures with care.
Please note! A comment makes the user aware of possible problems.
Tip: A tip makes the user aware of convenient functions and additional
options.
2.2 Safety and hazard notes
Warning! This device is only approved for connection to 230 V ’” / 50-60
Hz AC Voltage. It must be protected from heavy soiling and moisture. Different
uses to those described above can lead to damage to the device, e.g. short
circuit, electric shock etc. Always follow the safety and installation
instructions.
Warning! The only permitted power source is a 230 V ”’, 50/60 Hz mains
network socket. Never try to operate the device using a different voltage.
Warning! Only use this device indoors.
Warning! The device must be disconnected from the mains supply when
opening the cover or removing parts.
Warning! Never insert or remove the power plug with wet hands.
Warning! Never pull the power cord itself; only remove the plug from the
socket holding the grips on the mains plug.
Warning! Do not store or use inflammable materials or spray near the
device.
Warning! Do not use the device in an easily inflammable atmosphere (e.g.
close to fuel gas or spray bottles).
Warning! Do not cover the heater.
Warning! Never install the device close to taps, wash basins or other
water sources. Also never connect your heater to a power source if the surface
of the heater is damp.
Warning! Do not insert any objects into the openings on the device as
this risks injury, electric shock or damage to the device.
Warning! The casing heats up during operation. Install the in such a way
that accidental contact is avoided. The device only cools slowly after it is
switched off. Only transport it using the carrying handle that is designed for
this purpose.
Warning! Never dry inflammable objects in front of the discharge
openings.
Warning! During assembly please ensure that the connecting cable is not
crushed or damaged by sharp edges. If open points have been created by this
kind of damage then the device may not be reconnected to the supply network
for any reason.
Warning! Always remove the plug from the socket before cleaning the
device. Only clean using a damp (not wet) cloth.
Warning! Always remove the plug from the mains if the device is taken out
of service for a longer period. Store the heater in a dry, protected place for
this period.
Warning! If it can be assumed that safe operation is no longer possible
then the device must be taken out of operation and secured against accidental
operation. This is the case:
- if the device or the mains cable display visible damage;
- if the device no longer works;
- after a long period of storage under unfavorable conditions;
- following severe transport stress
Warning! Keep the product out of reach of children.
Warning! The device is not suitable for use in cattle breeding areas.
Warning! These operating instructions form a constituent part of the
device and shou ld be kept in a safe place. If the device is passed on to a
third party then these instructions should be passed on with it.
Warning! Never submerge the device in water.
Warning! The guarantee is not valid if the repairs are not carried out
correctly.
Warning! In commercial premises the accident prevention regulations of
the employers liability insurance association for electrical equipment and
facilities must be observed.
Warning! Never pour liquids over the device. In the event that this
happens remove the plug from the socket and consult a specialist.
Please note! This device is not designed for use by persons (including
children) who have limited physical, sensory or mental capabilities and also
not by persons with insufficient experience or knowledge of handling this
product except where they are monitored or instructed by a person who is
responsible for their safety.
Please note! After unpacking the device and before initial operation
please ensure that the device and all the relevant accessories are in good
working order. If transport damage is ascertained then please contact the
corresponding distributor or manufacturer immediately.
Please note! Consult a specialist if you have any doubts regarding the
functioning, safety or connection of the device.
Installation
Warning! Do not leave the packaging materials (plastic bags, polystyrene,
nails etc.) within reach of children as they represent potential hazards.
Warning! Electrical devices may only be operated in wet rooms connected
to a residual current circuit breaker.
Warning! Before initial operation of the device please ensure that this
connection is provided at the planned connection location.
Warning! The installation location must be selected so that the devices
cannot be sprayed with water or fall into water in any event.
Please note! Lay the connection cables in such a way that nobody can trip
over them and they cannot be crushed or come into contact with hot objects.
Please note! Only use extension cables that are compatible with the
output and in accordance with the valid safety regulations for the device.
Please note! Make sure that the devices are disconnected from the mains
power before and during installation.
When using the Palma 2.0 heater you have the choice of operation with or
without the included wet room thermostat Thermo 2. However for exact
temperature regulation and energy-saving operation we urgently recommend using
the Thermo 2.
To install the Palma 2.0, go to section 3.1.
To install the Palma 2.0 RAW, go to section 3.2.
Keep the Palma 2.0 clean and protect it from heavy soiling and moisture.
As described in the chapter Introduction and Technical Data on page 3, the
Palma 2.0 can be operated stand-alone (=Palma 2.0 RAW) or with the included
wet room thermostat Thermo 2.
However, for precise temperature regulation and energy saving operation the
use of the Thermo 2 is strongly recommended.
General control elements of the Thermo 2
3.2 Installation of Palma 2.0 heater
Warning! The distance from the inflammable objects should be at least
20”/ 50 cm. Adjust the heater so that there is a distance of at least 16”/ 40
cm between the wall and the air intake opening.
Warning! A free space of 1.5 meters should be left in front of the output
opening if possible.
Place the heater in your greenhouse (4).
Now insert the mains plug into the socket of the Thermo 2(5) or, if operating
without the Thermo 2, directly into the mains socket (6).
Warning! Never insert or remove the power plug with wet hands. When using
a multiple socket or an extension cable please ensure that the maximum current
carrying capacity is not exceeded. Cable drums must always be completely
unrolled. Do not wrap the connection cable around the device and never operate
the device with wound cable.
To set the Palma 2.0 RAW to wintermode, see section 4.2.
To set the Palma 2.0 to wintermode, see section 4.3.
To set the summer mode, see section 4.4.
Warning! Never insert or remove the power plug with wet hands.
Palma 2.0 Controls
Use the Palma 2.0 and Palma 2.0 RAW
4.1 General operation
When the desired room temperature is reached, turn the thermostat slowly
counterclockwise until you hear a ”click” (10). Due to the bimetal
thermostat’s measuring tolerance of ± 5 °C, it may be necessary to check the
set temperature with a thermometer and readjust it if necessary. To do this,
turn the thermostat switch in the desired direction (1-10).
Mode of the Palma 2.0
Device not in operation
Air circulation without heating (circulation in constant operation)
2 kW heating output (heating controlled by thermostat, air circulation in
constant operation)
4.2 Use the Palma 2.0 RAW in winter mode
Select position as the mode on the selector switch and set the thermostat to
maximum. The operation lamp will light up when the Palma 2.0 RAW starts with
heating (8).
Check the room temperature using a thermometer (9) .
When the desired room temperature is reached then slowly turn the thermostat in an anticlockwise direction until the operation lamp switches off (10).
The heater will now maintain the set temperature by re-starting the heating function when the room temperature falls below this level. In the event of temperature discrepancies you may need to adjust this a little.
It is not possible to print a temperature scale around the thermostat knob because the heating behavior will differ based on the environment the Palma 2.0 RAW is used in. For example the size, insulation, filling level and location of the greenhouse where the Palma 2.0 RAW is operated in, can make a significant difference. This is why it is recommended to use use the Palma 2.0 together with the optional and included Thermo 2 thermostat as described in chapter 4.3.
Select position as the mode on the selector switch. And set the heater thermostat to the maximum setting (12).
The wet room thermostat Thermo 2 will now take over temperature regulation and the Palma 2.0 heater will be switched on if the room temperature falls below the set level. If the temperature is reached then the heater will switch off again.
4.4 Use the Palma 2.0 and Palma 2.0 RAW in summer mode
Please note! The Thermo 2 is not required for summer operation. Just plug the
Palma 2.0 heater directly into a mains socket. In the summer months use of the
air circulation mode can achieve substantial reduction of the greenhouse
temperature.
Select mode 2 on the selector switch of the Palma 2.0 heater and open the door
or the roof window on your greenhouse (13). The position of the thermostat
switch is irrelevant here.
The greenhouse air that is heated by the sun is constantly circulated by the air circulation mode and thus moved outside. At the same time this measure regulates the humidity in the greenhouse and promotes the pollination of your plants.
4.5 Safety feature
Temperature controlled circuit breaker: If the device overheats the
temperature-controlled circuit breaker will switch the device off temporarily.
To switch the device back on, turn the heater off for 5 to 10 minutes to cool
down (14).
Another reason for the shutdown would be blockage of the intake or outlet opening.
- In this case please remove the corresponding objects (14). It could also be an indication that the ventilator has failed.
- In this case switch the heater off, remove the plug and contact an authorized specialist to arrange repair.
Cleaning, maintenance, environment and disposal
5.1 Cleaning and maintenance
Warning! Switch the device off before each cleaning and leave it to cool
for approximately 30 minutes before beginning cleaning.
Warning! Do not use any abrasive, caustic or cleaning materials. Clean
the casing with a damp cloth (not wet), vacuum cleaner or feather duster.
5.2 Environment and disposal
Please note! Only dispose of devices at a corresponding collection
centre.
Please note! Only authorized specialists are permitted to carry out
repairs on the device.
Please contact the manufacturer or distributor in this regard.
Warning! Incorrectly executed repairs can represent a hazard for the user
and other persons.
The manufacturer does not accept responsibility for any damage caused by
frost, insufficient heating performance for the room dimensions or
insufficient heat insulation.
ErP Product fiche according to EU 1188/2015
Model identifier(s):
Item No.:
Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat input, for electric storage local space
heaters only (select one)
Nominal heat output| Pnom| 2,0| kW| Manual heat charge control, with
integrated thermostat| No
Minimum heat output (indicative)| Pmin| N/A| kW| Manual heat charge control
with room and/or outdoor temperature feedback| No
Maximum continuous heat output| Pmax, c| 2,0| kW| Electronic heat charge
control with room and/or outdoor temperature feedback| No
Auxiliary electricity consumption| | | | Fan assisted heat output| No
At nominal heat output| elmax| N/A| kW| Type of heat output/room
temperature control (select one)
At minimum heat output| elmin| N/A| kW| Single stage heat output and no room
temperature control| No
In standby mode| elSB| N/A| kW| Two or more manual stages, no room temperature
control| No
| | | | with mechanic thermostat room temperature control| Yes
| | | | with electronic room temperature control| No
| | | | electronic room temperature control plus day timer| No
| | | | electronic room temperature control plus week timer| No
| | | | Other control options (multiple selections possible)
| | | | room temperature control, with presence detection| No
| | | | room temperature control, with open window detection| No
| | | | with distance control option| No
| | | | with adaptive start control| No
| | | | with working time limitation| No
| | | | with black bulb sensor| No
Contact details|
Bio Green GmbH & Co. KG
Marburger Str. 1b
35649 Bischoffen-Oberweidbach
Germany/Allemagne
Tel +49 (0) 6444 9312-0
Fax +49 (0) 6444 6162
E-Mail [email protected]
www.biogreen.world
PALMA EU VER. 3 – 10112021-BG