Dooya Curtain motor DT82TV/F-1.2/14 Manual
- June 8, 2024
- Dooya
Table of Contents
- Dooya
- Curtain motor
- SKU: DT82TV/F-1.2/14
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Set the motor rotation direction
- Parameter 10: Delete the limit position
- Parameter 2: Set to start holding hands
- Parameter 3: Weak electric switch mode
- Parameter 4: Strong electric switch mode
- Parameter 5: Limit position status
- Parameter 6: Device type
- Parameter 7: Power supply type
- Parameter 8: Manually set / cancel open borders
- Parameter 9: Manually set / cancel close borders
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Dooya
Curtain motor
SKU: DT82TV/F-1.2/14
Quickstart
This is a
secure
Window Covering – Pos/End Aware
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Quick press the outside set button in 1.5 seconds to trigger product inclusion
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
DOOYA Z-Wave curtain motor is designed with exceeding commercial standards, with its exceptional quietness and user-friendly setup. Multiple control options enable the users to operate the curtain by remote, APP, or with hands. Pull to move function would be especially helpful and convenient to users who are not yet familiar with motorization. Durability in use guarantee a 10,000 times use. Additionally, the motor is more than what were mentioned above. 1. Quick set limits: the motor would set its limit positions automatically with a full ride opening and closing on the track. 2. Soft start & soft stop: A smooth running with a soft start and soft stop provide a premium visual effect. 3. Pull to move: Just do what you always did on a normal curtain, but you do not have to pull the fabric all the way to the end. Just one touch of pulling on the fabric, the motor will start running until it reaches its end. 4. If the power was gone, you can still operate the curtain as a normal curtain. When the power is back, all the settings are still there. 5. RF compatibility: Dooya Z-Wave curtain motor is also compatible with the whole range of Dooya RF remotes, various choices and a different combination would satisfy all kinds of different needs.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Long press the outside set button for 15 seconds. (Please use this procedure only when the network primary controller is missing or otherwise inoperable.)
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Quick press the outside set button in 1.5 seconds to trigger product inclusion
Exclusion
Quick press the outside set button in 1.5 seconds to trigger product exclusion
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| GROUP 1 is lifeline service that assigned to curtain motor position. It
enables the curtain motor to send reports to Z-Wave Controller or Z-Wave
Gateway whenever the motor is starting or stopping. The Group Support:
SWITCH_MULTILEVEL_REPORT_V3 DEVICE_RESET_LOCALLY_NOTIFICATION
---|---|---
2| 5| GROUP 2 allows for Send Multilevel Report to associated devices in this
group.This Group Support: SWITCH_MULTILEVEL_REPORT_V3
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Set the motor rotation direction
Set the direction: This parameter can be used to set the motor rotation
direction, the motor direction is forward (Configuration Value set to 0) or
the opposite direction(Configuration Value set to 1), The default value is 0.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | the motor direction is forward |
---|---|
1 | the motor direction is opposite |
Parameter 10: Delete the limit position
Delete the limit: This command can delete the limit that has been set for
the motor.
Size: 1 Byte, Default Value: 127
SettingDescription
127 | Delete the limit position |
---|
Parameter 2: Set to start holding hands
Set to start holding hands: This parameter can be used to set the motor open
hand start function(Configuration Value set to 0) or closed(Configuration
Value set to 1), The default value is 0.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | open hand start function |
---|---|
1 | close hand start function |
Parameter 3: Weak electric switch mode
Configure weak electric switch mode: This parameter can be used to set the
need for weak electric switch mode. Provide 4 kinds of weak electric switch
mode is optional,respectively:Double-button reboundable switch(Configuration
Value set to 1),Double-button not reboundable switch(Configuration Value set
to 2),DC246 switch(Configuration Value set to 3),Single-button cyclic switch
mode(Configuration Value set to 4),The default value is 1.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | Double-button reboundable switch |
---|---|
2 | Double-button not reboundable switch |
3 | DC246 switch |
4 | Single-button cyclic switch mode |
Parameter 4: Strong electric switch mode
Configure strong electric switch mode:This parameter can be used to set the
need of strong electric switch mode. Provide 3 kinds of weak electric switch
mode is optional,respectively:Double-button not reboundable(Configuration
Value set to 0) ,Hotel mode(Configuration Value set to 1),Double-button
reboundable mode(Configuration Value set to 2),The default value is 0.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Double-button not reboundable |
---|---|
1 | Hotel mode |
2 | Double-button reboundable mode |
Parameter 5: Limit position status
Read whether the total limit is set:This parameter can be used to read the
motor’s total limit is already set.Not set the limit(Read into the
Configuration Value is 0);Already set the limit(Read into the Configuration
Value is 1)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Limit position does not set |
---|---|
1 | Limit position has been set |
Parameter 6: Device type
Read the device type: This parameter can be used to read the type of the
motor.Motor types are divided into curtain motor(Read into the Configuration
Value is 0x01), shutter(Read into the Configuration Value is 0x11), Venetian
blinds (Read into the Configuration Value is 0x12)
Size: 1 Byte, Default Value: 1
SettingDescription
1 | curtain |
---|---|
17 | shutter |
18 | venetian |
Parameter 7: Power supply type
Read the motor power supply type:This parameter can be used to read the
motor power supply type.The power of motor is classified into:Mains power
supply(Read into the Configuration Value is 0),battery power(Read into the
Configuration Value is 1).
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Main power (AC power) |
---|---|
1 | Bettery |
Parameter 8: Manually set / cancel open borders
Manually set/cancel open borders: Manually set the open boundary of the
curtain(Configuration Value set to 1), cancel manually open the border of the
curtain(Configuration Value set to 0)
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Cancel manually open the border of the curtain |
---|---|
1 | Manually set the open boundary of the curtain |
Parameter 9: Manually set / cancel close borders
Manually set /cancel close borders: Manually set the closed boundary of the
curtain(Configuration Value set to 1), cancel manually close the border of the
curtain(Configuration Value set to 0).
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Cancel manually close the border of the curtain |
---|---|
1 | Manually set the closed boundary of the curtain |
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Window Covering – Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 144 FW: 1.14:01.04 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18056102 |
Z-Wave Product Id | 0x030A.0x0103.0x0090 |
Window Covering Control Features | Automatic Calibration |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Basic
- Configuration
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Multi Channel Association V3
- Powerlevel
- Security
- Security 2
- Supervision
- Switch Binary
- Switch Multilevel V3
- Transport Service V2
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.