Simon Switch IO 10002034-13x && 10000322-039 Manual
- June 8, 2024
- Simon
Table of Contents
- Simon
- Switch IO
- SKU: 10002034-13x && 10000322-039
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Simon
Switch IO
SKU: 10002034-13x && 10000322-039
Quickstart
This is a ****
On/Off Power Switch
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
When the pushbutton is released after a press of (2sec<T<20sec) the device
will send a NIF to include from Z-Wave network or perform an association with
other Z-Wave device.Main LED will Blink with 0,3 sec period to inform that NIF
can be send after release of pushbutton.This process does not perform a
default reset of configurations.Main LED will Blink with 0,3 sec period to
inform that NIF can be send after release of pushbutton.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
When the pushbutton is released after a press of (20sec<T) the device will perform a factory default values operation, excluding it from network and resetng the configuration parameters.Main LED will perform 1 Blink with 5 sec.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to include from Z-Wave network or perform an association with other Z-Wave device.Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.This process does not perform a default reset of configurations.Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
Exclusion
When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to exclude from Z-Wave network or perform an association with other Z-Wave device.Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.This process does not perform a default reset of configurations.Main LED will Blink with 0,3 sec period to inform that NIF can be send after release of pushbutton.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 3| Z-Wave Plus Lifeline;Commands send to Life LineStatus Change: Command
Class Basic – Basic ReportOutput Power change more than 10%:Command Class
Meter – Meter Report
---|---|---
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Association LED
Used during Association process by Simon Shortcut Switch IO to turn ON the
main LED of all devices already associated to this shortcut.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Turns the main LED OFF |
---|---|
255 | Turns the main LED ON |
Parameter 10: Delay ON
delay from activation request until load activation.Please note that
possible values are referenced in HEX format from 0x00 to 0xFF (unsigned 1
byte values).Please Refer to u0022Z-Wave Command Class Specification, A-Mu0022
– > u0022Multilevel Switch Set Commandu0022 –> u0022Duration Tableu0022
specification to lean more about these values meaning.
Size: 1 Byte, Default Value: 0
SettingDescription
128 – 254 | Delay in minutes From 1 to 127 |
---|---|
0 – 127 | Delay in seconds |
Parameter 11: Activation Time
Time that load performs activated after complete an activation
process.Please note that possible values are referenced in HEX format from
0x00 to 0xFF (unsigned 1 byte values).Please Refer to u0022Z-Wave Command
Class Specification, A-Mu0022 – > u0022Multilevel Switch Set Commandu0022 –>
u0022Duration Tableu0022 specification to lean more about these values
meaning.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127 | Delay in seconds |
---|---|
128 – 254 | Delay in minutes From 1 to 127 |
Parameter 12: Behavior of LED in Repose
Configuration of Main LED as identification at 20%.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | LED OFF |
---|---|
255 | LED ON at 20% of maximum level |
Parameter 13: Lock Input
Locks the pushbutton and wired input actions.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Unlock the direct control of load |
---|---|
255 | Lock the direct control of load |
Parameter 15: Reset Default
Parameters, Groups, and Z-Wave status are restored to default. (Only
writable)
Size: 2 Byte, Default Value: 0
SettingDescription
39015 | Device persorms a factoy default Reset |
---|
Parameter 16: Delay OFF
delay from deactivation request until load deactivation.Please note that
possible values are referenced in HEX format from 0x00 to 0xFF (unsigned 1
byte values)Please Refer to u0022Z-Wave Command Class Specification, A-Mu0022
– > u0022Multilevel Switch Set Commandu0022 –> u0022Duration Tableu0022
specification to lean more about these values meaning.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127 | Delay in seconds |
---|---|
128 – 254 | Delay in minutes From 1 to 127 |
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 4.18.72.15.65.15 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16115315 |
Z-Wave Product Id | 0x0x26.0x0001.0x0000 |
Firmware Updatable | Updatable by Consumer by RF |
Neutral Wire Required | ok |
Switch Type | Push Button with Indicator |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>