Thermo-Floor AS Multireg Z-Wave TF016 Manual
- June 8, 2024
- Thermo-Floor AS
Table of Contents
- Thermo-Floor AS
- Multireg Z-Wave
- SKU: TF016
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Technical Data
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Thermo-Floor AS
Multireg Z-Wave
SKU: TF016
Quickstart
This is a ****
HVAC-Thermostat
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Inclusion/exclusion modeTo include the thermostat to your home automation
gateway, press the Center (confirm) button for 10 seconds.The display will
show OFF. Press Right (down) button 4 times till you see Con in the display.
Now start adding device in your home automation software. Start inclusion mode
by pressing Center (confirm) button for approximately 2 seconds. The
inclusion/exclusion icon will appear in the display.Confirmation will show
Inc/EcL in the display. If inclusion fails, Err (error) will appear.
Please refer to the
Manufacturers
Manual for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Heatit Z-Wave is an electronic thermostat for mounting in a standard wall box. The thermostat has a built-in Z-Wave chip that can be connected to Home Automation systems like Fibaro, Sensio, Vera, Zipato and others.The display will show the actual room temperature.By pressing the buttons, the display will show the set value.Heatit Z-Wave is equipped with a single-pole switch. The thermostat can handle loads up to 16A/3600W at 230V.If the load is greater than this, the thermostat needs to be connected to a contactor. It can be used with two external temperature sensors.Functions: Room sensor Floor sensor Temperature limiter Power regulator Z-Wave chip 500 series Week program/setback temperature via gateway Setback mode 7-segment white LCD- screen Can be used in connection with different NTC-sensors Lock mode/child lock Backlight Calibration 8 scenariosCONNECTION CLAMPSUse 1,5 mm or 2,5 mm cables according to power need.TECHNICAL DATARated voltage: 230 V 50/60 HzMax. load: 3600WMax. current: 16APower consumption: 1,5WProtection class: IP21Min/Max installation temp: -20C to 40CMin/Max operating temp: 5C to 40CTemperature intervals: Floor sensor 5C to 40CRoom sensor 5C to 40CHysteresis: 0,5CSensor values: 0C 29,1 kOhm10C 18,6 kOhm15C 15,1 kOhm20C 12,2 kOhm25C 10,0 kOhmBreaker: Single-pole
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Factory reset – RES:By pressing buttons Left and Center(up and confirm) for 20 seconds, the thermostat will perform a complete factory reset.NB! Please use this procedure only when the primary controller is missing or otherwise inoperable.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Inclusion/exclusion modeTo include the thermostat to your home automation gateway, press the Center (confirm) button for 10 seconds.The display will show OFF. Press Right (down) button 4 times till you see Con in the display. Now start adding device in your home automation software. Start inclusion mode by pressing Center (confirm) button for approximately 2 seconds. The inclusion/exclusion icon will appear in the display.Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear.
Exclusion
Inclusion/exclusion modeTo include the thermostat to your home automation gateway, press the Center (confirm) button for 10 seconds.The display will show OFF. Press Right (down) button 4 times till you see Con in the display. Now start adding device in your home automation software. Start inclusion mode by pressing Center (confirm) button for approximately 2 seconds. The inclusion/exclusion icon will appear in the display.Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
If Er2 appears in the display, touch any button to restart the display.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 8 | Z-Wave Plus Lifeline |
---|
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Thermostat – HVAC |
Network Operation | Always On Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.00 |
Certification ID | ZC10-15010002 |
Z-Wave Product Id | 0x019B.0x0001.0x0001 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.