FISHER and PAYKEL 60cm Built Under Dishwasher
OVERVIEW
Designed to fit flush under the kitchen benchtop with a custom kickstrip. Available in stainless steel to match Fisher & Paykel’s Contemporary family of appliances.
MODELS
Built-under Dishwasher, 60cm, Sanitise, Stainless steel finish
DW60UC4X2
SERIES & STYLE
Series 7
Contemporary
FEATURES
- Can be installed under bench heights between 820–880mm, fitting flush with cabinetry for a seamless look
- 15 place setting capacity and easily accommodates plate sizes up to 320mm
- Seven wash programs including Auto, Eco and 60 Min cycles
- Dry+, Sanitise, Half Load and Intensive wash modifiers for added flexibility
- Fan-assisted drying with auto door opening at the end of the cycle to remove excess moisture
- Fully flexible racking including height-adjustable middle basket and cup racks, wine glass supports, full-width utensil tray and cutlery basket
- Front-of-door controls with status display and interior LED lighting
- Wi-Fi capability and SmartHQ™ app connectivity for remote control and notifications
- With 4.5 star energy and 5.5 star water rating*
- Quiet wash performance, running at a low decibel rating of 42dBA**
*Energy and water ratings subject to change. Final certification pending.
**Noise levels subject to change
PRODUCT SPECIFICATIONS
- Model No. DW60UC4X2
- Dimensions H 820-880mm W 597mm D 574mm
- Electrical
- Supply 230V, 50Hz
- Service 10A
- Receptacle 3-prong grounding-type
- Plumbing
- Supply 3/4 BSP (20mm) connector water inlet hose
- Pressure Min 34.5 kPa, max 1034 kPa
Cold water connection @ max 20°C
PRODUCT DIMENSIONS
- A Overall height* 820-880
- B Overall width** 597
- C Overall depth 574
- D Depth of open door 620
- E Height of custom toe kick panel 65-200
- F Minimum width of custom toe kick panel*** min. 595
- G Depth of toe kick recess**** 52 – 122
- H Height from floor to door panel base 103-163
PLUMBING AND ELECTRICAL **
**
Service outlet at rear extends both sides, hoses and cords can be routed to
either or both sides.
*Depending on adjustment of levelling feet.
CAVITY DIMENSIONS: STANDARD INSTALLATION
- **A Minimum overall height*** min. 820
- B Minimum overall width 600
- C Minimum overall depth min. 580
*Depending on adjustment of levelling feet
90002435 Date: 21.07.2022 | Product specifications may vary from those shown
in this Preliminary Specification Guide. This document is superseded and will
become obsolete upon launch of the product.
This Preliminary Specification Guide should not be used as installation
guidance for any product. Further information is required to safely and
correctly install the products featured here. Specific
installation guidance will be available with the product on delivery and on
our website fisherpaykel.com