Hisense DH5021KP1W 50 Pint (23.7L) Capacity, 2-Speed Dehumidifier User Manual

June 9, 2024
Hisense

Hisense - logo DH5021KP1W 50 Pint (23.7L) Capacity, 2-Speed Dehumidifier
User Manual

Product Overview

Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed Dehumidifier -
fig **** The figues in this manual are based on the external view of a standard model. They may differ from that of the dehumidifier you have selected.

DEHUMIDIFIER SAFETY

Your safety and safety of others are very important We have provided many important safety messages in this manual and on your appliance. Always read and follow all safety messages.
** This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol with the word “DANGER” or “WARNING” These words mean:
DANGER A hazard that If not avoided, will result In death or serious Injury.
WARNING** A hazard that If not avoided, could result In death or serious Injury. All safety messages will tell you what the potential hazards are, tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed.

IMPORTANT SAFETY INSTRUCTIONS

DANGER
To reduce the risk of explosion, fire, death, electric shock, scalding, or injury to
persons when using this appliance, follow basic precautions, including the following:
INSTALLATION

  •  Plug into a grounded 3 prong outlet. Do not remove ground prong.
  • Never attempt to operate this appliance if it is damaged, malfunctioning, partially disassembled, or has missing or broken parts, including a damaged cord or plug.
  • Do not use an electrical adapter or multiple-outlet adaptors with this dehumidifier.
  • Do not use an extension cord.
  • Unplug dehumidifier before servicing.
  • Do not drink water collected in the water bucket.
  • The appliance is not intended for use by young children or impaired people without supervision, young children should be supervised to ensure that they do not play with the appliance.
  • When installing or moving the appliance, be careful not to pinch, crush, or damage the power cord.
  • Keep packing materials out of the reach of children. Packaging material can be dangerous for children. There is a risk of suffocation.
  • Do not use the appliance in standing water or allow the product to be directly splashed by water during use.
  • Store and install the appliance where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.
  • Call an authorized service technician to repair or immediately replace all power cords that have become damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end.
  • Do not use the product if the outlet is damaged or loose.
  • In the event of a gas leak (propane gas, LP gas, etc.) do not operate this or any other appliance. Open a window or door to ventilate the area immediately.
  • Do not disassemble, repair or modify the product.
  • Do not store or use flammable gases or materials near the dehumidifier.

OPERATION

  • Read all instructions before using the appliance and save these instructions.
  • Do not tamper with controls.
  • Push the power plug all the way into the wall outlet so that it is not loose.
  • Do not grasp the power cord or touch the appliance controls with wet hands.
  • Do not modify or extend the power cord.
  • If the product makes a strange noise or emits a smell or smoke, pull the power plug out and contact Ilisense customer service.
  • Avoid placing the dehumidifier or other heavy objects on top of the power cord.
  • Do not use water to clean the dehumidifier.
  • Keep the air inlet and outlet free from obstructions.
  • Do not cover the power cord with a rug or carpeting. Placing heavy objects on top of the cord could damage it.
  • Keep the product away from fire and high heat.
  • Do not use the product in places where it could be splashed by water.
  • Do not insert fingers, sticks etc. into the air inlet or outlet. The fan is running at high speeds and could cause personal Injuries.
  • Do not repair or replace any part of the appliance. All repairs and servicing must be performed by qualified service personnel unless specifically recommended in this owner’s manual. Use only authorized factory parts.
  • Connect to a properly rated, protected, and sized power circuit to avoid electrical overload.

Warning To reduce the risk of injury to persons .maoneton. or amaoe to me product or property when using this appliance, follow basic safety precautions, including the following:
INSTALLATION

  • Use this appliance only for its intended purpose.
    This product is not designed for preserving precision instruments, tableware or art works.

  • Never unplug the appliance by pulling on the power cord. Always grip the plug firmly and pull straight out from the outlet.

  • Do not use the product in places where chemicals are used. Chemicals and solvents dissolved in the air could cause product deformation and leaking,

  • Turnoff the dehumidifier and pull out the power plug before cleaning. Wait for the fan to stop moving.

  • Do not operate the dehumidifier without a filter. Using the product without a filter could result in a reduced product lifespan, electric shock or injury.

OPERATION

  • Do not use the product for preserving animals/plants, precision instruments, art works etc.
  • Do not place any objects on top of the dehumidifier.
  • Turnoff the dehumidifier and empty the water bucket before moving the dehumidifier.
  • Pullout the power plug if you will not be using the product for an extended period.
  • Do not use the product in a very small space such as a closet. Poor ventilation could result in overheating.
  •  Do not use wax, thinner or a strong detergent when cleaning. Wipe the product using a soft cloth.
  • Do not use the product in direct sunlight or rain.
  • Do not touch the product with wet hands.
  • Position the product on a firm, stable surface.
  • Remove cable ties and extend power cord before use.
  • Do not spray foreign substances or water on the product.

STORAGE AND DISPOSING OF THE UNIT

  • Dispose of this appliance in accordance with Federal and Local regulations.
  • Refrigerants must be evacuated before disposal.
  • Please recycle or dispose of the packaging material of the product in an environment-friendly manner.
  • To avoid damage to the compressor, never store or ship the appliance upside down or sideways

INSTALLATION REQUIREMENTS

Electrical Requirements
WARNING
Electrical Shock Hazard
Always plug into a grounded three-prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock.
Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.
Power Supply Requirements

  • 115V (103.5 min. to 126.5 max.)
  • 15A time-delay fuse or circuit breaker

Recommended Grounding Method
This dehumidifier must be grounded. This dehumidifier is equipped with a power supply cord with a three-prong grounding plug. The cord must be plugged into a mating, grounded three-prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to have a properly grounded three-prong outlet installed by a qualified electrician.
It is the customer’s responsibility:

  • To contact a qualified electrical installer.
  • To assure that the electrical installation is  adequate and conforms to the Nation

Electrical Code, ANSI/NFPA 70-last edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
Nation Fire Protection Association

  1. Batterymarch Park Quincy, Ma 02169-7471 www.nfpa.org

Location Requirements
Warning To reduce the risk of injury to persons. aroneton. or amade to me rod«tor property when using this appliance, follow basic safety precautions, including the following:
NOTE: Your model may differ from the one shown.

  • Do not locate outdoors. This dehumidifier is intended for indoor, residential use only. This dehumidifier is not recommended for commercial use.
  • Allow at least 12″ to 18″ (30.5 cm to 45.7 cm) of space on the rear and sides of the dehumidifier for models with back louver and above the dehumidifier for models with top louvers.
  • You will need a surface strong enough to support the dehumidifier when its bucket is full of water.
  • You will need a surface level enough to keep the water from spilling when the bucket is full of water.
  • Do not block the louvers of the unit.
  • Never operate this dehumidifier in an area that is likely to accumulate standing water. If this condition develops, for your safety disconnect the power supply before stepping into the water.

DEHUMIDIFIER USE

Setting the Controls
Control Panel
Control Type 1Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed
Dehumidifier - fig 2Control Type 2 Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed Dehumidifier - fig
3NOTE:

  • Set point is Relative Humidity: lower is more dry, higher is less dry.
  • The control panel of your model may differ from the one shown above.

Starting Stopping the Dehumidifier
Warning The dehumidifier Should be upright for at least 2 hours before use.
NOTES:

  • Before turning on the dehumidifier, be sure that the bucket is empty and fits all the way into the dehumidifier.
  • Each time you unplug the dehumidifier or power is interrupted, the controls will return to the previous settings when power is restored.
  • Humidity displayed is between 30% Relative Humidity and 90% Relative Humidity.
  • Humidity can be set between 30% Relative Humidity and 80% Relative Humidity.
  • It’s important to set the desired humidity level to an achievable setting. To ensure energyfefficient operation, only use the dehumidifier in a closed space, with no open windows or other sources of moist air (to avoid continuous running).
  • Operating temperature is between 38°F to 90°F (3.2°C to 32.2°C). At temperatures of 38F(3.2°C) or less, water freezes inside the product. At temperatures over 90F(32.2°C), the internal temperature of the product trips a protective device which deactivates the product to avoid product damage.
  • The compressor has a 3­minute delay before restarting. If the product is stopped and immediately restarted, to protect the compressor there is a 3­minute delay until the compressor restarts.
  • When the dehumidifier is operating, the indoor temperature will rise.
    The dehumidifier does not have a cooling /heating function. Heat is generated during operation, so the room temperature may be increased by about 6°F(3°C) depending on the usage conditions (indoor temperature, size of the room).

WARNING
Electric Shock Hazard
Always plug into a grounded three-prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death. fire or electric shock.

  1. Plug into a grounded three-prong outlet.
  2. Press POWER to turn on the dehumidifier.
  3. Press FAN to choose the fan speed.
  4. Press MODE to choose the mode.
  5. Press the plus or minus button to set the level of humidity.
  6. Press POWER to turn off the dehumidifier.

NOTE:
In the event of a power failure, your dehumidifier will operate at the previous settings when the power is restored.
Empty Bucket Light
If this light is on, the fan and the compressor will stop running.This light indicates that you need to check:

  • If the bucket is full, empty and re-install bucket.
  • If the bucket is not in position, remove the bucket and re-install it. Make sure the bucket fits all the way into the dehumidifier and the bucket light is off, or dehumidifier
    will not run.

Fan Speed

  1. Press FAN to select fan speed.
  2. Choose LOW, HIGH or AUTO.
  • LOW-Reaches the desired humidity setting with lower sound level.
  • HIGH-Willmore quickly reach the desired humidity setting.
  • AUTO-Achieves set humidity at normal speed.0

NOTE:
Once the relative humidity of the room hit the desired setting, the compressor will stop and the fan will be off periodically.
The fan may periodically turn on, to read the humidity level, without the compressor running.
Desired Humidity-Mode

  1. Press MODE to select the desired humidity setting.
  2. Choose Auto Dry, Continuous or Manual Set.
    • AUTO DRY: The dehumidifier will operate in dry mode only. The fan speed is set automatically. The desired humidity is set to 50% automatically.
    •  CONTINUOUS: The dehumidifier will operated continuously. The fan speed can be adjusted. The desired humidity can not be adjusted.
    •  MANUAL SET: The dehumidifier will operate at the selected fan speed to the set humidity level. If the humidity level of the room is higher than the desired humidity setting, the compressor will turn on. If the humidity level of the room is lower than the desired humidity setting, the compressor will turn off, as well as the fan.

NOTE:
The de-icing function will turn off the compressor if a low temperature condition occurs. Pressing the MODE button or the plus or minus button will not increase or decrease the amount of moisture removed. When the de-icer senses then correct operating temperature, the compressor will cycle back on. Some freezing is normal will dehumidifiers are used at low temperatures.
Power
Press POWER to turn on or turn off the dehumidifier.

Humidity Level

  1. Press the Plus or Minus button to set the desired humidity level. Desired humidity in the digital display will flash for 5 seconds after operation.
  2. Actual room humidity will be displayed after 5 seconds of flashing the desired humidity.

NOTE:
Humidity can only be adjusted manually in Manual Set mode. In Continuous and Auto Dry mode, humidity level is set automatically.
Digital Display
Display shows relative humidity or time (depending on setting).

  1. When the dehumidifier operates in Manual Set mode, the display shows the relative humidity of the room.
  2. When the timer is selected, the display shows the time when the dehumidifier will turn on or turn off operates, depending on the setting.

NOTE:
The humidity displayed is only for reference. For accurate humidity, please check a hygrometer.
Timer
To set Timer for a 30-minute to 24-hour delay before the dehumidifier is turned off (the dehumidifier must be On):

  1. Press TIMER. Timer indicator light will come on, and the display will flash. The display will show remaining time before the dehumidifier will turn off.
  2. Press the Plus or Minus button to change the delay time, from 30 minutes to 24 hours.

To set Timer to turn on the dehumidifier, with previous setting:

  1. Turn off the dehumidifier.
  2. Press TIMER. Timer indicator light will flash. The display will show remaining time before the dehumiditier will turn on.
  3.  Press the Plus or Minus button to change the delay time, from 30 minutes to 24 hours. To clear the Timer delay program:

NOTE: Dehumiditier can be either on or off.

  1. Press TIMER once after it has been programmed. Display will show remaining time.
  2. While the display is showing the remaining time, press TIMER again. Timer indicator light will turn off.

To see the remaining time.
Press TIMER once after it has been programmed.
Display will show remaining time.
NOTE:
Empty the drain water bucket before setting the timer function. If the water bucket becomes full during the Timer function, the Empty
Bucket light goes on and dehumidification stops.
Clean Filter

  1. When the Clean Filter indicator light is on, remove, clean and replace the air filter. See “Cleaning the Air Filter”.
  2. Press the Clean Filter button to reset the filter monitor.

NOTE:
When the light is on, it will remain on for 180 hours or until you press Clean Filter button.
Pump (for Pump function model only)
This feature pumps water horizontally or vertically. Pump water to a drain, out a window or anywhere you think suitable.
IMPORTANT:
You must connect the drain hose to the unit before pressing the Pump button, or the pump will not operate. See “Pump drain” for connecting instructions

  1. Press PUMP to activate the pump system for active drainage.
  2. Once the pump button is pressed, the pump light will switch on.

Note

  • If the pump light flashes, it means that the pump is not functioning properly.
  • If the drain hose is not correctly connected to the unit or is bent, the pump light will flash and the pump system will not work. See “Trouble shooting” for direction.

Site for installing hose for pump function:Hisense DH5021KP1W 50 Pint
\(23.7L\) Capacity, 2-Speed Dehumidifier - fig 4

Draining the Dehumidifier
**
WARNING
Sickness Hazard Do not drink water collected in water bucket. Doing so can result in sickness.
Option 1 Bucket Draining
** If a floor drain is not available, or you do not plan  to run your dehumidifier continuously, you maywant to simply empty the bucket.

  1. Grasp the bucket sides to slide out bucket.
  2. Lift the bucket up by the handleHisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed Dehumidifier - fig 6
  3. Pour water into a sink or tub.
  4. Fold down the handle and reinstall the bucket

IMPORTANT:
If the Empty Bucket light comes on, the dehumidifier will not operate. The bucket may need to be emptied or re-installed.
Note

  • If the water bucket is removed immediately after turning off the dehumidifier, the water remaining in the heat exchanger may drip inside the water bucket storage area. Remove the water with a soft cloth
  • While cleaning, do not touch the water level float.
  • Clean the water bucket once a week during use.
  • If the ambient temperature is low, there is less moisture in the air for the product to remove.
  • Unplug the product before removing the water bucket. If the bucket is removed while the product is operating, the compressor will stop.

Option 2 Gravity Draining
If you plan to run your dehumidifier continuously, you can choose direct draining by attaching a garden hose to the unit.
NOTE:

  • The garden hose sold separately.
  • And the drain hose inner diameter should greater than 1/2”.
  • The connector is designed for North American garden hoses only

IMPORTANT:
In North America the garden hose connectors are 3/4” diameter straight (non- tapered) thread with a pitch of 11.5 threads per inch(male part has an outer diameter of 1 1/16 inches (26.99mm).
For models without pump:

  1. Turn off the dehumidifier and unplug the power supply cord.

  2. Uncover the connector cover on the side of the unit.Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed Dehumidifier - fig 9

  3. Remove bucket

  4. Attach a garden hose to the drain hose connector on the inside of the dehumidifier. Securely attach the hose to be sure there is no water leak A. Garden hose
    B. Drain hose connector

  5. Reinstall bucket.

For models with pump :

  1. Turn off the dehumidifier and unplug the power supply cord.
  2. Uncover the connector cover on the back of the unit.
  3. Attach a garden hose to the drain hose connector on the back of the dehumidifier. Securely attach the hose ensure there is no water leak.Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed Dehumidifier - fig 11A. Garden hose
    B. Drain hose connector
    C. Connector cover

WARNING
Take care not to injure hands while connecting the hose.
NOTE :
Place the other end of garden hose into a floor drain. Check to see that the hose lies flat and is in the drain. Make sure all the parts of the hose is on a lower level than the hose connector on the dehumidifier.Also ,the outlet of the hose should at lest 5.5″ lower than the hose connector . The hose should not be kinked or pinched. Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity,
2-Speed Dehumidifier - fig 12Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed
Dehumidifier - fig 13NOTE:

  1. To use the bucket without the garden hose, simply remove the garden hose, then reinstall bucket.
  2. For models with pump ,you may also cover the connector cover after remove the garden hose.
  3. The bucket must be installed and properly aligned for the dehumidifier to operate .

Option 3 PUMP-Drain (for models with pump only)
This feature can help to pump water horizontally or vertically with a 16 feet (487.68cm) hose included. You can also pump water to a floor drain, out a window or anywhere you think suitable.
NOTE:
You must connect the drain hose to drain hose connector before pressing Pump button. If the pump does not function properly, see “Trouble shooting” for direction.

  1. To connect the drain hose to the unit,uncover the connector cover on the side of the unit,and pass the hose through the side hole.
    Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed Dehumidifier - fig
14

  2. Insert the drain hose into the Drain hose connector and ensure the hose is plugged to the bottom of the connector.

To disconnect the drain hose
Method 1:push the “PUSH”button on the connector through the side hole (Do not release) , in the meantime pull the Drain hose out,and cover the connector cover Method 2:Slide out the bucket ,pinch the “PUSH” button by the finger(Do not release) as following picture shows, in the meantime pull the drain hose out,cover the connector cover and reinstall the bucket.
NOTE:

  • To make sure no leakage,it is recommended a 1″ short piece of the drain hose should be cut off after 3 times disconnection.

Water filter cleaning (For pump function model only)

  1. Unplug the unit before cleaning it.
    After every 3 months of usage, the water filter need to be cleaned for a smooth water pump running.

  2. Remove the bucket.

  3. Remove the plastic nut, sealing bolt and take the filter off.
    NOTE: Before remove the filter, please put a draining dish under the unit and make sure there is not water draining from the port. Warning Take care not to injure hands while disassemble and re-install the water filter parts.

  4. Clean the water filter with soft brush.
    • If the filter is very dirty, wash it in water and a neutral detergent.
    • Clean the water filter every 3 months.

  5. Re-install the filter, filter sealing bolt and lastic nut back to the unit, make sure the filter is installed to the right position.Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed Dehumidifier - fig 22

  6. Re-install the bucket to the unit.

IMPORTANT:
The Water Filter needs to be cleaned EVERY 3 Months on Models with internal Pump.
NOTE:
If the unit will not used for a certain period of time, please clean the water filter, drain the dehumidfier completely. And make sure re-install the water filter parts.
Service calls to clean the water filter are not covered under the product warranty.
Normal Sounds
When your dehumidifier is operating normally, you may hear sounds such as:

  • Compressor sounds, which may be loud.
  • Air movement from the fan.
  • Clicking sounds when the dehumidifier or compressor turns on and off, and when the Automatic shut-off Switch is working.

DEHUMIDIFIER CARE

Your new dehumidifier is designed to give you many years of dependable service. This section explains how to clean and care for your dehumidifier.
To avoid damage to the compressor, never store or ship the appliance upside down or sideways.
Cleaning the Air Filter
The air filter is removable for easy cleaning. A clean filter helps remove dust, lint, and other particles from the air and is important for best operating efficiency. Check the filter every two weeks to see whether it needs cleaning.

  1. Turn off the dehumidifier.
  2. Remove the air intake grill.
  3. Take out the air filter.
  4. Use a vacuum cleaner to clean the air filter if the air filter is dirty, wash it in warm water with a mild detergent.
  5. Reinstall the air filter and the air intake grill.
  6. Turn on the dehumidifier.

NOTE:
Do not wash air filter in the dishwasher or use any chemical cleaners. Air dry filter completely before reinstalling to ensure maximum operating efficiency. Hisense DH5021KP1W 50 Pint \(23.7L\) Capacity, 2-Speed Dehumidifier - fig
25Cleaning the Dehumidifier
Exterior

  1. Turn off the dehumidifier and unplug the power supply cord.
  2. Dust the surface of the unit with a soft cloth or the dusting attachment of your vaccum cleaner.

Water Bucke
Every few weeks, rinse the inside of the water bucket with a mild detergent to avoid growth of mold, mildew and bacteria.
Water level float
The dehumidifier has a EMPTY BUCKET light and a water float. The bucket must be properly aligned for the water level float and the EMPTY BUCKET light to work.
NOTE:
Be sure the float is snapped correctly in place.

TROUBLE SHOOTING

Before calling for service, try the suggestions below.
Dehumidifier will not run

  • Is the dehumidifier turned on? Turn on the dehumidifier.

WARNING
Electrical Shock Hazard
Plug into a grounded three-prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord. Failure to follow these instructions can result in death, fire or electric shock.

  • Is the power cord plugged into a grounded three-prong outlet? Plug into a grounded three-prong outlet. See “Electrical Requirements” on page 5.

  • Has a housed hold fuse blown or has a circuit breaker tripped?
    Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician. See “Electrical Requirements” on page 5.

  • Is the bucket installed properly? Reinstall the bucket so that it fits all the way into the dehumidifier.

  • Does the bucket need to be emptied? Empty the bucket.

  • Is the water level float in place? Remove the bucket. Make sure the float is snapped in place. Reinstall the bucket.

  • Did the dehumidifier suddenly stop operating, and won’t turn on? Confirm the power is connected, and the bucket is in place. If the unit still doesn’t operate, call Hisense for Warranty service.

Dehumidifier runs but does not dehumidify

  • All models have an automatic de-icing function that will shut off the compressor and allow the fan to run. When the de-icing function senses the correct operating temperature, the compressor will cycle back on.
  • The filter is dirty or obstructed debris. Clean the filter.

Air coming from the dehumidifier is warm

  • Dehumidifier will put out warm air under normal operating conditions.

Dehumidifier displays error codes

  • If the dehumidifier displays an error code, please contact Hi sense customer service.Hisense - logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals