iCON Nova PD3V101 Studio Condenser Microphone User Manual
- June 9, 2024
- Icon
Table of Contents
- iCON Nova PD3V101 Studio Condenser Microphone
- Important Safety Instructions
- Introduction
- What’s in the package
- Register your ICON ProAudio product to your personal account
- Features
- Operating the Nova
- Specifications
- Services
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
iCON Nova PD3V101 Studio Condenser Microphone
Important Safety Instructions
- Read this manual thoroughly before using this unit.
- Keep this manual for future reference.
- Take notice of and comply with all warnings included in the user’s manual or indicated on the appliance.
- Follow all instructions included in this manual.
- Do not expose this unit to rain or moisture. Avoid having water or other liquids spilled on this unit.
- Do not block any ventilation openings or interfere with the proper ventilation of this unit. Install in accordance with the manufacturer’s instructions.
- Do not use or store near any heat sources such as radiators, heat registers, stoves, or other heat- producing appliances.
- To avoid the risk of electrical shock, do not touch any exposed wiring while the unit is in operation.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this unit and all connected electrical equipment during lightning storms or when left unused a long period of time.
- Refer all servicing to qualified service personnel. Servicing is required when the appliance has been damaged in any way or fails to operate normally.
Introduction
Firstly, congratulations on your purchase of the ICON Pro Audio Nova Studio
condenser microphone! In these pages, you’ll find a detailed description of
the features of the Nova Studio condenser microphone and a full list of
specifications.
Please register the product on our website at the link below
www.iconproaudio.com/registration:
As with most electronic devices, we strongly recommend you retain the original
packaging. In the unlikely event that the product is returned for servicing,
the original packaging (or reasonable equivalent) is required. With proper
care and adequate air circulation, your Nova Studio condenser microphone will
operate flawlessly for many years to come.
We trust that this product will provide years of excellent service and in the
unlikely event that your product does not perform to the highest standard,
every effort will be made to address the issue.
What’s in the package
- Nova Studio condenser microphone
- Shock Mount
- Pop shield
- Aluminum Case
Register your ICON ProAudio product to your personal account
1. Check serial number of your device
Please go to http://iconproaudio.com/registration or scan the QR code below.
Input your device’s serial number and the other information on the screen.
Click “Submit”.
A message will pop up showing your device information such as model name and
its serial number – Click “Register this device to my account” or if you see
any other message, please contact our after-sales service team
Log in to your personal account page for existing user or sign up for new user
- Existing user: Please log into your personal user page by inputing your user name and password.
- New user: Please click “Sign Up” and fill in all the information.
Download all useful materials
All your registered devices under your account will show on the page. Each product will be listed along with all its available files such as drivers, firmware, user manual in different languages and bundled software etc. for download. Please make sure you have download the necessary files such as driver before you begin device installation.
Features
The Nova large diaphragm condenser microphone is perfect for vocal
performance, broadcast, acoustic instruments and amplifiers. It’s versatile
and affordable.
Using extremely high end components like Wima capacitors and Fairchild
resistors, the Nova combines a beautiful, slick appearance with top grade
performance.
- High degree of clarity for any voice or instrument applications
- Professional hand-build 34mm large-diaphragm capsule for full, open-sound and unsurpassed audio quality
- Ideal as a primary or support microphone for a variety of recording situations
- Cardioid pickup pattern for outstanding sound source separation and feedback rejection
- Pressure-gradient transducer with shock-mounted capsule
- Perfect for vocals and acoustic instruments
- Ultra-rugged construction with electro-plated finish
- Top-quality components including a Wima capacitor and Fairchild transistor
- Suspension shock mount and innovative zero-hassle “magnet-slip on” pop filter
- Aluminum storage case is included
- Magnetic, slip on pop filter
Operating the Nova
Powering the Nova (48V)
The Nova is a condenser microphone and therefore needs to be operated by
connecting a phantom power supply. Phantom power is standard on most quality
mixers, outboard mic pre-amps (MIC pres), and hard disk recorders. If
necessary an external phantom power supply can also be used. The Nova receives
the phantom power directly from a microphone cable when connected to a mixer
or other microphone input that includes a phantom supply. The power is
actually sent OUT of the microphone INPUT, riding silently along with the
audio signal. Most mixers have a switch to engage the phantom power so be sure
to check that the phantom power is on.
Setting up the signal level
When connecting the Nova to a mixer or recorder input, be sure that the input
is at a suitable level. Also, be sure that the 48V phantom power is engaged as
explained above. Most mixers and recorders of reasonable quality will offer a
microphone input with MIC trim (usually called Trim or Gain) control. The
purpose of the MIC trim control is to optimize the amount of good signal to
any noise associated with the mixers electronics. A good MIC pre with trim
also will have a Peak or Clip LED. To set a good level on the MIC, set the
Nova up in front of the desired sound source and slowly raise the MIC trim
control until you see the Peak LED light up. Then, turn the mix trim control
down until the LED does not light any more. On most mixers, the ideal setting
is that the trim control is turned up as much as possible without lighting the
Peak LED.
Microphone Placement
In order to maximize the sound quality, please pay careful attention to the
placement of your Nova and how it is positioned for the instrument or vocalist
that you are miking. All microphones, especially unidirectional or cardioids
microphones, exhibit a phenomenon know as the “proximity effect”. Very simply
put, proximity effect is a resulting change in the frequency response of a
microphone based on the position of the MIC capsule relative to the sound
source. Specifically, when you point a cardioid MIC directly at the sound
source (on-axis) you will get the best frequency response, however, when you
start pointing the microphone slightly away (off-axis) you will notice the low
frequency dropping off and the microphone will start to sound thinner.
For most vocal applications you’ll want to position the microphone directly in
front of the artist. The same may be true for miking instruments. However, you
can make some pretty amazing equalization adjustments by slightly changing the
angle of the capsule to the sound source. This can be a very useful technique
in capturing the optimum sound of drum set, acoustic guitar, piano or other
instruments in a live room or sound stage. Experimentation and experience are
the best teachers in getting good sounds, so plug in!
P-Poping
P-Poping is that annoying pop that you can get when the microphone diaphragm
gets a blast of air from a vocalist pronouncing words with the letter “P”
included.
(because it is a “plosive” syllable). The Nova has a built-in a pop filter
which sits inside the net basket (or cradle) to minimize the pop effect.
Simply drop it in – a magnet will secure it’s fixture.
Mounting the Nova
Mount your Nova into the provided suspension mount and secure using the screws
on the underside. Secure your pop-shield into the special magnetised connector
.
Specifications
- Transducer type ………………………………………………………………..electrostatic
- Operating principle ……………………………………………………………presure gradient
- The diaphragms active diameter …………………………………………34mm
- Frequency range ………………………………………………………………20 Hz to 20 kHz
- Polar pattern …………………………………………………………………….unidirectional,cardioid
- Sensitivity (dB re iV/Pa) ……………………………………………………..-35dBV+/-3dB
- Output impedance …………………………………………………………….50 Ω
- Rated load impedance ………………………………………………………1000 Ω
- Suggested load impedance ………………………………………………..>250 Ω
- Maximum SPL for 0,5% THD at 1000 Ω load ………………………..132 dB
- S/N Ratio DIN/IEC 651 A-weighten ………………………………………82 dB-A
- Equivalent noise level DIN/IEC A-weighten …………………………..10 dB-A
- Dynamic range of the microphone preamplifier ……………………..124 dB
- Phantom powering voltage on pin 2 &3 of XLR ………………….+48V (+/-4V)
- Current consumption ………………………………………………………≤4 mA
- Output connector ……………………………………………………………..3-pin XLR male
- Dimension ………………………………………………………………………60mmX60mmX154mm
- Weight ……………………………………………………………………………0.363kg
Services
If your Nova needs servicing, follow these instructions.
Check our online Help Center at http://support.iconproaudio.com, for
information, knowledge, and downloads such as:
- FAQ
- Download
- Product Registration
- Video Tutorials
Very often you will find solutions on these pages. If you don’t find a
solution, create a support ticket at our online Help Center at the link below,
and our technical support team will assist you as soon as we can.
Navigate to http://support.iconproaudio.com
and then sign in to submit a ticket. Once you have submitted an inquiry
ticket, our support team will assist you to resolve the problem with your ICON
ProAudio device as soon as possible.
To send defective products for service:
- Ensure the problem is not related to operation error or external system devices.
- Keep this owner’s manual. We don’t need it to repair the unit.
- Pack the unit in its original packaging including end card and box. This is very important. If you have lost the packaging, please make sure you have packed the unit properly. ICON is not responsible for any damage that occurs due to non-factory packing.
- Ship to the ICON tech support center or the local return authorization. See our service centers and distributor service points at the link below:
If you are located in US
Send the product to:
North America
Mixware, LLC – U.S. Distributor 3086 W. POST RD.
LAS VEGAS NV 89118
Tel.: (818) 578 4030
Contact: www.mixware.net/help
If you are located in Europe Send the product to: Sound Service GmbH
European Headquarter Moriz-Seeler-Straße3 D-12489 Berlin
Telephone: +49 (0)30 707 130-0
Fax: +49 (0)30 707 130-189
E-Mail: info@sound-service.eu
If you are located in Hong Kong Send the product to:
ASIA OFFICE:
Unit F, 15/F., Fu Cheung Centre, No. 5-7 Wong Chuk Yueng Street, Fotan,
Sha Tin, N.T., Hong Kong.
Tel: (852) 2398 2286
Fax: (852) 2789 3947
Email: info.asia@icon-global.com
5. For additional update information please visit our website at: www.iconproaudio.com
References
- Domain im Kundenauftrag registriert
- Icon Pro Audio (@iconproaudio) • Instagram photos and videos
- Help - Mixware
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>