FCC Notice

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC CAUTION

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.

The FCC ID for this radar is “2A8U2SWR-A001”.

NOTE

This equipment should be installed to a pole or other infrastructure at a height of more than 2.8 meters for keeping the radiator some distance from person’s body. It is recommended that the radar be installed at a height of 3.5m to 5m to ensure full performance.

Introduction

60GHz Radar SWR-A001 is installed on the roadside and detects pedestrians based on reflected radio waves. The radar communicates with the data acquisition equipment via Ethernet and outputs detection results every 100ms.

Installation Instruction
Figurer 1. System configuration

No ITEM DESCRIPTION
1 Detection Area Max. 60m x 30m
2 Installation Height 3.5 to 5m (typ)
3 Required Setbacks 3m
4 Max. Number of Detections 40 people
5 Output Data Classification*, position, velocity, direction
6 Data Output Cycle 100ms

Table1.Detection performance

Specification

No ITEM DESCRIPTION
1 Power Supply DC12V
2 Power Consumption Less than 10W
3 Temperature -40 to +75°C
4 Humidity 25 to 98%
5 Waterproofing IP67
6 Dimensions H:120mm x W:130mm x D:36mm
7 Weight Less than 2kg
8 Radar Frequency 61.0 to 61.5GHz
9 Interfaces Ethernet 100BASE-T

Table 2 shows general specifications.

Installation method

Installation requirement
To ensure the best performance of the radar, it should be installed at a height between 3.5m and 5m. Also, since it is difficult to detect the area directly below the radar, it should be installed 3m behind the pedestrian crossing.

Installation Instruction
Figure 2. Installation requirement

Horizontal adjustment

Adjust the horizontal angle so that the radar is facing the middle of the crosswalk on the other side.

Installation Instruction
Figure 3. Horizontal adjustment

Vertical adjustment

Attach the radar to horizontal arm using the mounting bracket. Adjust the elevation angle according to the detection area using an angle meter or similar device.

Adjust the angle according to the detection area. (Using an angle meter)
Installation Instruction
Figure 4.Vertical adjustment

Equipment Connection

The Radar has a RJ-45(jack) connector and supports passive PoE. Use CAT 5e cables. The Radar starts up when the power supply is connected.

Pin No. FUNCTION
1 Ethernet TX+
2 Ethernet TX-
3 Ethernet RX+
4 DC+12V
5 DC+12V
6 Ethernet RX-
7 0V
8 0V

Table 3. RJ-45 connector pin assignments

Tool Operation Procedure

  1. Start the detection result drawing tool “AreaConfigCreator.exe”.

  2. Once the tool is activated, click “Receive Start” at the lower left of the screen.
    Tool Operation Procedure
    Figure 5. Detection result drawing tool

  3. When data is received, the detection result is displayed on the screen.
    Tool Operation Procedure
    Figure 6. The results of detection

Documents / Resources

| SUMITOMO ELECTRIC SWR-A001 Pedestrian Sensor [pdf] User Manual
SWR-A001, SWRA001, 2A8U2SWR-A001, 2A8U2SWRA001, SWR-A001 Pedestrian Sensor, SWR-A001, Pedestrian Sensor, Sensor
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals