MEDIFYAIR MA-18 Portable Air Purifier User Manual
- June 2, 2024
- MEDIFYAIR
Table of Contents
MA-18
AIRPURIFIER
READ AND SAVE THESE INSTRUCTIONS
INSTRUCTION MANUAL AND WARRANTY INFORMATION
Lifetime warranty if replacing filters on time
User Manual
IMPORTANT SAFETY INSTRUCTIONS:
IN ORDER TO AVOID ANY DAMAGE TO YOU, OTHERS OR PROPERTY, FOLLOW THE FOLLOWING
SAFETY PRECAUTIONS:
IF THE POWER CORD OR UNIT DOES NOT WORK, CONTACT MEDIFY CUSTOMER SERVICE
IMMEDIATELY.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRICAL SHOCK, OR INJURY
TO PERSONS:
- Do not touch power plug with wet hands. Wet hands can cause an electrical shock. Never touch with wet hands.
- Do not take apart or modify unit without authorization. Taking apart or modifying without authorization may cause personal injury or unit malfunction.
- Do not damage power line and socket. Do not bind wires when you use the unit. It may cause an electrical shock, a short circuit, or a fire to happen if you use broken wires. Forbidden to cut, scratch, refit, distort, twist or pull power lines. Do not put any heavy products on top of wires or sockets.
- Prohibited use beyond power. Can only use a 220v unit with a 220v power supply. Can only use a 110v unit with a 110v power supply. You can break or ruin the circuit boards if you plug into a 220v power supply.
- Turn off the power before cleaning machine. Unplug before cleaning to avoid electrical shock or unit turning on accidentally.
- Do not put bars or metal products nearby air outlet or openings. If metal bars touch inside of machine it can cause electrical shock.
- Regularly clean power plug. Do not allow dust to accumulate on power plug. This can damage insulation and cause a fire accident to occur. Pull out the power plug and clean with dry cloth (do not use wet cloth). If not planning to use the machine for any extended period of time, unplug it for safety reasons.
- Please insert the plug completely into the power socket before starting the air purifier. If not, this may cause an electrical shock and overheating, even a fire accident. Do not use damaged plug or loose socket.
- Keep machine dry. Or else it may cause electrical shock or a fire accident to happen.
- Do not use air purifier in a greasy area. This machine should not be used as ventilating or air evacuating equipment.
- Do not use the air purifier in the room with fumigation type pesticides. Chemical residue could be accumulated inside the machine and then released, causing harm. The room should keep ventilated thoroughly after you use an insecticide and then start to use air purifier.
- Do not use solvents like benzene, diluent, etc. to clean the air purifier. This can cause the air purifier to break, to become damaged, or short circuit, which can lead to an electrical shock or even a fire accident happening.
- Keep machine away from volatile substances or flammable items. Otherwise, that could cause a fire to occur.
- Do not use air purifier in high temperature or humid conditions. These situations may cause current damage, an electrical shock, or a fire accident to happen.
- If you use the air purifier in a room with an electric heater, ensure proper ventilation. Otherwise, there could be a buildup of carbon monoxide, which can cause serious harm or death. The air purifier will NOT remove carbon monoxide from the air.
- Be careful when removing the plug from the power socket. Do not pull wires which may cause a short circuit or damage to wires, to avoid a possible fire accident or an electrical shock.
- BEFORE USING THIS PRODUCT, PLEASE MAKE SURE TO REMOVE THE PLASTIC COVERING FROM ALL THE FILTERS.
- Please turn off the power immediately in case of any of the following situations:
– Malfunction of any switch
– Circuit failure
– Abnormal heating of wires or plugs
– Any burnt smell, abnormal sound, or shock
– Any other malfunction
SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE.
UNIQUE FEATURES & SPECIFICATIONS
GENUINE MEDIFY TRUE HEPA H13 FILTRATION SYSTEM
-
TRUE HEPA H13 FILTRATION
Removes up to 99.9% of airborne particles as small as 0.1 microns, such as allergens, pollen, dust, germs, pet dander, odors, mold spores, and smoke from air that passes through the filter. -
CARBON ODOR FILTRATION
Reduces household odors and VOCs (volatile organic compounds)/gases as shown by independent laboratory testing. -
PRE-FILTER
Captures large particles.
3 SPEEDS
Low, medium, and high speeds.
REPLACE FILTER INDICATOR
Illuminates when it is time to replace the filter.
FILTER PURIFICATION
-
PRE FILTER
Removes hair, fibers, and large particles like dander. -
TRUE HEPA H13 FILTER
The high-efficiency H13 TRUE HEPA filter is tested to removed 99.9% of particles down to 0.1 microns.
This higher grade of HEPA filter easily catches pollen, dust mites, and other tiny airborne particles you can’t see. -
ACTIVATED CARBON FILTER
Substantial carbon filter with carbon pellets remove toxic odors, smoke, and formaldehyde.
TECHNICAL DATA
- Voltage: 110-120 V AC 60 Hz
- Rated power: 35 W
- Noise level: <59 dB(a)
- Room size: up to 140 sq. ft.
- Unit dimensions: 11.2″H x 8.4″W x 8.4″D
- Unit weight: 5.3 lbs.
CONTROL PANEL
| FILTER REPLACEMENT INDICATOR
---|---
NEGATIVE ION SWITCH
HIGH SPEED INDICATOR
MEDIUM SPEED INDICATOR
LOW SPEED INDICATOR
POWER ON/OFF
HOW TO USE
POWER ON/OFF
In standby mode, tap the “Power ON/OFF” button and the unit will turn on. To
resume standby mode, hold down this button for 3 seconds.
FAN SPEED ADJUSTMENT
Once unit is turned on, the fan speed will default to low. To control fan
speed, press “Power ON/OFF” button again. Each time this button Is tapped, the
fan speed will cycle through the following: low speed, medium speed, high
speed, low speed, etc.
NEGATIVE ION SWITCH
Press to turn on the negative ion function. Press again to turn off this
function.
FILTER INSTALLATION
INSTALLING FILTER SET
All filters must be used together. Do not disassemble filter set.
1. Remove filter cover at the bottom of the air inlet. Press firmly and turn
left in the direction indicated by the arrow to remove the bottom cover.| 2.
Remove the filter, which is enclosed in the plastic bag.
---|---
|
3. Remove the plastic bag.| 4. Re-insert the filter. Re-attach the filter
cover and turn right to lock it in place.
|
FILTER REPLACEMENT
FILTER REPLACEMENT INDICATOR
This monitors the filter and notifies you when the filter must be replaced.
When this light turns on, please turn off the unit and replace the filter.
After replacement is complete, press and hold the Reset button for 3 seconds.
The unit will beep, the filter replacement sensor will reset, and the reminder
light will turn off.
- Take the filter out from the air purifier, as shown in Figure A.
- Remove the packing bag of the new filter, as shown in Figure B.
- Put the new filter inside the air purifier and reconnect the bottom cover, as shown in Figure C.
- Plug in the power cord and turn on the air purifier.
- Press and hold the Filter Replacement Indicator button for 3 seconds. The filter reset indicator light will turn off. This means the unit is successfully reset. The unit will begin counting down from 2,000 hours.
ATTENTION
Please remove all packaging on the filters before use.
Do not use the air purifier without filters.
When replacing the filter, you must reset the filter replacement indicator.
CLEANING AND MAINTENANCE
Please make sure to pull out the power plug before cleaning the unit. Do not
immerse machine in water or any other liquid. Do not use abrasive, corrosive
or flammable products to clean any parts of the unit.
The unit uses composite filters, so filters cannot be washed.
CLEANING THE AIR PURIFIER
Clean the air purifier regularly to prevent the dust accumulation.
- Use soft and dry cloth to remove the dust from the air purifier.
- Use soft and dry cloth to clean the outlet and inlet of the air purifier.
TROUBLESHOOTING
PROBLEM | POSSIBLE CAUSE | POSSIBLE SOLUTION |
---|---|---|
Unit will not operate | Filter cover not installed correctly | Remove bottom |
cover and re-install
Bottom cover not locked in place| Check that the bottom cover is turned into
locked position
Power supply for plug| Pull out the plug and plug it back into unit
Incorrect power plug or wire| Contact customer service
Fan does not work| Machine doesn’t turn on| Plug it in and turn it on
Motor is not working| Contact customer service
Machine on uneven ground| Move it to even and flat ground
Loose or foreign particles inside| Contact customer service
Filter packaging is not removed| Remove plastic covering from filters
Motor is loose| Contact customer service
Performance issues| The filter needs to be replaced| Replace the filter with
genuine Medify Air replacement filters for best performance
Air intake or outlet is blocked| Contact customer service
Filter packaging not removed| Remove the packaging from filters
Not enough space surrounding the unit| Ensure 10-inches distance between sides
of air intake and that distance to air outlet is not less than 8 in.
Lack of filter or filter is not properly installed| Make sure all filters are
placedin the order in accordance with instructions
Coverage area questions| Check whether room area surpasses coverage area
estimates
WARRANTY INFORMATION
If you have any additional questions, please contact customer service. All
names and trademarks are property of Medify Air. Our company reserves the
right to change the product at any time, without prior notice, and the company
has no obligation to adjust any products supplied earlier. Please refer to the
detailed warranty terms below. To register for the lifetime warranty, please
fill out the attached form and mail it to:
Medify Air
1325 SW 30th, Avenue
Deerfield Beach, FL 33442
Or complete the lifetime warranty registration available on our website
(preferred method): www.medifyair.com
LIFETIME WARRANTY
Medify guarantees your Medify Air Purifier to be free of defects in material
or workmanship for a lifetime period, provided you have completed and returned
your warranty registration to Medify Air within the first 30 days of purchase,
and that the filters are replaced with original and genuine Medify Air
replacement filters at least once every three to four (3-4) months or after
2,500 hours of use. Within the first 30 days, Medify Air will replace the
defective unit at no charge to you and reimburse you for any shipping charges.
After 30 days, Medify Air’s obligation and liability under this Lifetime
Warranty is dependent on your use of our genuine filters, purchased on our
website or from our authorized resellers, which can be found on our website.
Prohibited use beyond power. Can only use a 220v unit with a 220v power
supply. Can only use a 110v unit with a 110v power supply.
You can break or ruin the circuit boards if you plug a 110v plug into a 220v
power supply.
Our Lifetime Warranty remains in effect as long as:
- You submit your warranty registration to Medify Air within 30 days of purchase.
- You change filters with genuine and original Medify Air replacement filters at least once every three to four (3-4) months or after 2,500 hours of use (whichever comes first).
- You use a proper power supply based on voltage: 110-120 V (North America & Japan) or 220-240 V (all other regions).
- There is no evidence of tampering, mishandling, neglect, accidental damage, modification, and/or repair done to the Medify Air purifier by anyone other than authorized Medify Air service personnel.
- Your air purifier is operated in accordance with the provided instructions.
This Lifetime Warranty is provided by:
Medify Air
1325 SW 30th, Avenue
Deerfield Beach, FL 33442
www.medifyair.com
info@medifyair.com
888-258-1008
Please visit our website for details on efficacy test data:
medifyair.com/pages/reports
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>