WARELIGHT WL-SIUFO-100W-50K-DMV UFO High Bay Instruction Manual

June 3, 2024
WARELIGHT

WARELIGHT WL-SIUFO-100W-50K-DMV UFO High Bay Instruction Manual

WARNING

  • This UFO High bay within the input voltage range:100 277VAC,50/60Hz.
  • If input voltage exceeds this range, it may cause light failure. Please be sure to operate under correct input voltage.
  • Ensure ambient operating temperature of -40°F(-40°C) through 113°F(45°C).
  • Using this UFO High bay in temperatures outside of this range will reduce the UFO High bay lifespan.
  • Make sure to turn off power before starting the installation process.

INSTALLATION INSTRUCTION

HOOK TYPE

HOOK TYPE

PRODUCT DIMENSION

Wiring Connection

Turn off the power,connect AC wire. black wire to L,white wire to N,and green wire to E.

Twist in sensor installation manual

installation

WIRING CONNECTION

WIRING CONNECTION

  • Emergency unit cannot be used in combination with the motion sensor
  • imming leads must be connected between Emergency unit output and fixture dimming input leads whether a dimmer is being used or not

HOOK TYPE

  1. Hang the emergency driver to hook, lock the safety rope to somewhere be able to hold the emergency driver. If no suitable place, please lock it to the hook.

  2. Hang the UFO high bay to the emergency driver bottom hook.

  3. Connect the emergency driver output wire to the Driver input wire through waterproof connector.

  4. Tighten the Screw to lock UFO high bay with emergency driver

  5. Connect the emergency driver input wire to line voltage for the end.”

Product description

  • Suit for 30W to 300W lamp with 0-1 0V dimming industrial lights.
  • Used with LiFePO4 battery.
  • 150-200VDC output.
  • LED emergency converter that can transfer standard LED fitting into emergency LED fitting.
  • Accessary test switch and charge indicator.

Product description

Applications
UL Listed for wet locations.

  • For use on a wide range of LED fittings to convert them from standard to emergency fitting.
  • Output DC150-200V.
  • Additional Relay that can control standard LED driver.
  • Deep discharge protection.
  • Ambient range ta 10 …. 60°C.
  • IP65 protection.
  • Not intended for use in luminaries for high-risk task area lighting

Dimensions
L20SxW20SxH110 mm L8.1’x W8.1’x H4.3′

Dimensions

Technical dataItem •. .
Rated input voltage
100-277VAC, 50-60Hz
Input current
150mA
Input power
8.5W max
Power factor
0.6 @100VAC
Output wire L-out N-out (LED load input)
AC 6A Max
Output voltage range
DC150-200V
Max output voltage
250V
Battery pack voltage/capacity
LiFePO4 12.8V 6600mAh, 84.48Wh
Recharge current
0-S00mA
Recharge time
24hours
Discharge time
90 minutes
Max. casing temperature
tc 6

Protections

  • Input over current protection.
  • Output over voltage protection.
  • Output under current protection.
  • Output short circuit protection (Emergency mode)

Remote control
REMOTE CONTROL

  • If you press TEST button once, the system will go into discharging mode for 5 seconds , then it goes back to charging mode.
  • If you press H-T (Hold test button), the system goes into discharging mode and keeps discharging ; then you press it again , the system will stop duscharging and go back to working mode.
  • The Max remote control distance is 15 M.

Test switch
TEST SWITCH

  • Emergency conversion Kit will go into emergency mode if test switch is pressed when main supply is on, while it will go into charging mode if test switch is not pressed.
  • In emergency mode, press the test switch for 3 seconds to turn off the current emergency state. LED indicator
  • Red stable:charging mode or charging full.
  • Red off:main power off or discharging mode.
  • Red flash:0.5 second fast flash-represents failure. 2 second slow flash-represents low battery voltage and needs recharging.

Self-test mode

  • After connecting the AC wires and turn on the main power, the emergency driver will be in self-test mode for 3 seconds.
    When it is in the processing of self-test :
  1. The indicator in red will flash every 2 seconds;
  2. It goes into charging mode , If suddenly the main power is cut off, the emergency driver may stop working.
  • If the self-test is not passed, then it goes into failure mode.
    The indicator in red will flash in every half second, The main reasons are as below:
  1. The battery pack is not wired of connection or it is broken.
  2. The load is not connected or in short. Or the dimming signal wires are not connected properly.
  • If the emergency driver pass the self test and it will go into working mode: The indicator keeps red. It is in the charging mode and it passed the self-test , and all functions are working well.
  • Remark: If the battery voltage is lower than 30% rated voltage, the indicator will flash in every 2 seconds. Once the battery capacity or voltage goes above the 30% of the rate capacity, and it will goes into self-mode again.

Installation instruction: – It is only used for 1-1 OV dimmable <300W lighting fixtures. – Please check and confirm all the data and usage surrounding before installation. – Damp or wet location installation is OK. – Please keep it away from the flammable materials with a place of good heat dissipation. – Please charge the battery consistently for >24 hours for the first time usage so as to activate the whole battery cells of discharging/charging duration.

Installation instruction:

Maintenance:

  • Please turn off the main power every 3 months, so as to let the battery  operate a charging/discharging circle. This will help make battery sustain a longer lifetime.
  • Please check the emergency function with the push test button.
  • Battery capacity is >60% when factory deliver goods, so it could be consistently stocked for Max 12 months.
    Notes:
    Users are not suggested replacing the batteries by themselves. If needed, please use the nominated batteries pack by the manufacturer and contact with us for the instructions of maintenance

Warranty

  1. Warranty 5 years.
  2. Except for the following circumstances:
  3. Improper installation or operation.
  4. Misuse.
  5. Abuse.
  6. Unauthorized or improper repair alteration.
  7. Accident or negligence in use, storage, transportation.
  8. Any natural acts.