Linshang LS176 portable spectrophotometer User Guide
- June 3, 2024
- Linshang
Table of Contents
Linshang LS176 portable spectrophotometer
Please read this manual carefully before using and reserve it for reference.
Product Introduction
The instrument is a smart multifunctional colorimeter. It has a 3.5-inch IPS color display and capacity touch panel, which has an excellent operating experience. The instrument integrates multiple color charts and can quickly match the measured color to the closest color code. It also has color difference comparison function, color difference threshold can be set and a variety of color difference formulas can be selected to achieve rapid QC testing. The instrument meets the requirements about grade 1 colorimeter in the Chinese JJG 595-2002 Verification Regulation of Colorimeters and Color Difference Meters in all directions employing full-spectrum LED light source and advanced spectral sensor..
Parameters
Illumination geometry | D/8, specular component include (SCI) |
---|---|
Illumination light source | Full spectrum LED light source |
Spectral Range | 400-700nm |
Spectral Interval | 10nm |
Measuring aperture | 8mm |
Measurement conditions | Light source D65, field of view 10° |
Measuring time | About 1s |
Color space
| CIE Lab, Luv, LCh, Yxy, CMYK, RGB, Hex, WI-98, WI-Gauz,
WI-Hunter, YI-98, Reflectance
Color difference formula| ΔEab, ΔEuv, ΔE94, ΔEcmc(2:1), ΔEcmc(1:1), ΔE00
Repeatability
| Standard deviation ΔEab is within 0.03 (Measurement condition: the average
value of 30 measurements on the whiteboard at an interval of 3s after
calibration)
Inter-Instrument Agreement| △Eab<=0.4, based on avg. of 12 BCRA series II
tiles
Dimension| 179mm 64.5mm 93mm
Weight| About 325g
Power supply
| Rechargeable lithium battery 3.7V@4000mAh, can measure 10,000 times
continuously under full charge
Display| 480 * 320 dot matrix IPS color screen
Language| Simplified Chinese, English
Charging port| USB (Type-C)
---|---
Operating temperature range| 0~45℃, 0~85%RH (no condensation)
Storage temperature range| -25~55℃, 0~85%RH (no condensation)
Features
- The instrument is fashioned with a full-spectrum LED light source and spectral sensor, and it meets the requirements of the national metrology grade 1 machine.
- Adopt a 3.5-inch capacity touch panel with human-machine interaction interface for convenient operation.
- Contains multiple electronic color charts, which can quickly match the closest color code with a color chart matching accuracy rate higher than 90%.
- QC testing function: the color difference threshold can be set and a variety of color difference formulas are optional.
- A variety of color spaces are available, suitable for various needs of color measurement.
- Can store 1000 colors and 1000 color comparison records with large storage space.
- The instrument has a built-in compensation optical path with stable values, allowing long-period calibration.
- With built-in rechargeable lithium battery, the instrument can measure continuously for 10,000 times under full charge.
Operation
Power on/off
- Power on: Short press the power button to turn on the colorimeter.
- Power off : Long press the power button to turn off the colorimeter or press “Power off” in the menu bar,
If automatic power off is set, the instrument will automatically power off as no operation time exceeds the set value, when the time of no operation is longer than the set automatic power off time.
Calibration
After entering “calibration” interface, you can perform calibration operation
as the calibration animation, or skip the calibration. It is recommended to
calibrate after a long time of no usage.
You can also set the language in calibration interface. If displayed in
Chinese, press “English” for English; if displayed in English, press “中文” for
Chinese.
For failed calibration, the possible reasons are as below:
- The bottom cap is not closed properly;
- The standard tile on the bottom cap needs to clean;
- The attenuation of the light source leads to failure of normal use and it needs to be returned to the factory for inspection and repair.
Measurement
To enter the main measurement interface, there are two modes: “Color Scan” and “Color Compare”. You can press the button at the bottom of screen to switch and the selected mode will turn blue.
Color Compare
In the “Color Compare” interface, press the “Scan Standard” button to set current value as standard. Press the “Scan Sample” button to use current value as sample. Short press the button to scan, and this value will replace the last record.
When the standard is measured or added and sample is measured, color difference between the two colors will be calculated with the following results:
-
LabCh difference Δ
LabCh difference Δ: sample color data minus standard color data. The color cast direction between the two is judged by ΔL, Δa and Δb. -
ΔE value
The value of ΔE is calculated according to the selected color difference formula. -
QC test
Suitable for color difference inspection in production process. If ΔE is higher than the set threshold, it will read “unqualified” and shown in red; if ΔE is less than or equal to the set threshold, it will read “qualified” and displayed in green.
The following steps can be performed after completing the color difference comparison:
-
Save
To save the comparison result, press “Save” on the upper right corner. You can choose default or name the record manually. -
History
If users need to view the saved comparison results, click “History” to view the color difference comparison record, and enter the history interface to view the next record by sliding left and right. -
Lab/LCh/
Click this button, you can switch back and forth between the 3 interfaces of Lab, LCh and reflectance spectrogram. -
ΔE Setup
Set ΔE calculation formula and QC test threshold. -
Save standard
The standard color can be saved in “My Colors” for further use. -
Input standard
The user can manually input the Lab value or LCh value as standard. -
Add standard
You can choose any color in “My Color” as standard. Press the “Add Standard” button, select any color you want in “Add Standard” interface, the selected color will be used as the standard color and get back to Color Scan interface.
Color Scan
In the “Color Scan” interface, short press the button or press “Scan” button on LCD screen to trigger the color scan.
The interface will be as below:
- Sample Data: After scan, the scan button area will display the color data. The user can set the data type in Setting.
- Color Matches: According to the color chart selected by the user, the closest three color codes are matched and displayed
The following steps can be performed after completing the color scan:
-
Save
Press “Save” on the upper right corner to save scanned color in “My Colors”. The record can be saved with a default name or named manually. -
History
If users need to view the saved comparison results, click “History” to view the color difference
comparison record, and enter the history interface to view the next record by sliding left and right. -
Lab/
Click this button, you can switch back and forth between the 2 interfaces of the data value interface and the reflectance spectrogram. -
Color Chart
Select one set of color charts for matching, then samples will be only compared within this chart. Three closest color codes will be matched. -
Setting
Select parameters for the scanned color
Menu bar
In the measurement interface, click the ” ” icon on the upper left corner to pop up the menu bar, with the following options: Settings, My colors, Compare History, Device info, Calibration and Power Off
Settings
Items in “Parameter Setting” include: ΔE setting, color chart selection, parameter setting, shutdown time setting, language and restoring default settings.
-
ΔE Setup
ΔE setup includes ΔE threshold setting and color difference formula selection. There are six color difference formulas: ΔEab, ΔEuv, ΔE94, ΔEcmc(2:1), ΔEcmc(1:1), ΔE00 and ΔE*00. The ΔE threshold is used for QC testing the range of 0.1-50. -
Select Color Chart
To select a set of color charts for color matching in the “Color Scan” interface. -
Color Format
There are 11 color spaces including Lab, Luv, LCh, Yxy, CMYK, RGB, Hex, YI-98, WI-98, WI-Gauz, and WI-Hunter. -
Auto Off setting
Choose whether to set the auto off and auto off time with a range is 1-30 minutes. -
Language
Support Simplified Chinese and English. -
Restore to defaults
To restore parameters to the factory settings.
-
My Colors
Colors scanned by the user are stored in “My colors”, up to 1000 records. You can swipe the screen to turn pages, delete, modify names, search, and view color data.
Compare History
Color compares are stored in “Compare History”, up to 1000 records. You can slide the screen to turn pages, delete, modify the name, search and view the comparison records.
Device Info
“Device Info” displays the basic information of the instrument, including: Device Model, Serial number, Production date, Calibration date, Battery level, Firmware Version, and Device Status. -
Calibration
The instrument can be calibrated in Calibration interface at any time. -
Power Off
Press “Power off” to power off the instrument.
Precaution
- When the colorimeter has not been used for a long time, it is recommended to perform calibration before using.
- Please ensure that the sample is evenly colored with a flat and clean surface, otherwise it will affect the measurement accuracy.
- After the base is removed from the host, it should be stored in a clean place to avoid contamination of the standard tile.
- Do not insert any object inside the colorimeter to clean it, as this will damage it and affect measurement accuracy and operational safety.
- Charge the colorimeter in time when the battery is out of power.
- If not in use over 6 months, charge it regularly to prevent the battery from over-discharge and damage.
- It’s recommended to calibrate the instrument once each year. And we offer calibration service.
- Due to different mobile phone displays, there may be a slight color difference between the actual color and the color displayed on the mobile phone App.
Locating Plate
In order to meet the requirements for precise alignment of some measurement areas, the colorimeter is equipped with a locating plate
Packing List
No. | Description | Quantity | Unit |
---|---|---|---|
1 | Colorimeter | 1 | Set |
2 | USB cable | 1 | pcs |
3 | Cleaning cloth | 1 | pcs |
--- | --- | --- | --- |
4 | Locating plate | 1 | pcs |
5 | User manual | 1 | pcs |
6 | Certificate / Warranty card | 1 | pcs |
Service
- The colorimeter has one-year warranty. If the meter works abnormally, please send the whole instrument to our company for maintenance.
- Provide users with spare parts and lifelong maintenance services.
- Provide the users with the gauge calibration service.
- Free technical support for long term.
Manufacturer: Shenzhen Linshang Technology Co., Ltd.
Website: www.linshangtech.com
Service hotline: +86-755-86263411
Email : sales21@linshangtech.com
4-8-2021
References
Read User Manual Online (PDF format)