MediCrystal Infrared Heating Amethyst Mat – Full Size 72″x24″ – Natural Crystals User Guide

June 3, 2024
MediCrystal

MediCrystal Infrared Heating Amethyst Mat – Full Size 72″x24″ – Natural

Crystals

MEDICRYSTAL® FULL SIZE MAT SET INCLUDES:

  • SIZE: 72″x24″ (180×60 cm)
  • HEATING AREA: 60″x23″ (150×56 cm)
  • FIR HEAT ADJUSTABLE FROM 86°F TO 158°F
  • 2 BIMETAL SENSORS
  • 3 THERMOSTAT SENSORS
  • 14 lbs OF CRUSHED AMETHYST CRYSTALS
  • HEATING POWER: 240W
  • VOLTAGE: 110V, 60Hz
  • TOTAL WEIGHT: 27 lbs
  • GROSS WEIGHT: 30 lbs

INSTRUCTIONS

MediCrystal Infrared Heating Amethyst Mat 2

  1. Layer 1 – High-quality heat-resistant reddish-brown eco-suede, elegant, soft, comfortable, durable, and easy to clean, featured with MediCrystal® Logo on the top.
  2. Layer 2 – Transparent film with triangle shape, which acts as a window to view Amethyst crystals.
  3. Layer 3 – High grade «A-AB» crushed to 2-10 mm and tumbled natural, not chemically treated Purple Amethyst. Hot crystals release heating Far InfraRed (FIR) rays and Negative Ions.*
  4. Layer 4 – Bamboo carbon fiber cotton with high mineral content accumulating heat for even thermal distribution.
  5. Layer 5 – Non-woven functional fabric layer for increased release of Negative Ions.
  6. Layer 6 – Oxford waterproof fabric layer to protect inner mat sensors and heating systems from moisture and sweat.
  7. Layer 7 – Electronic-wave proof copper fiber fabric EMI (Electro-Magnetic Interceptor) layer for primary shielding user from any remaining electromagnetic fields (EMF).
  8. Layer 8 – Aluminum foil EMI layer blocking EMFs and uniformly distributing the heat to the upper layer with gemstones.
  9. Layer 9 – Durable 0.2 mm non-woven glass fiber fabric layer for heating wire fixing and protection.
  10. Layer 10 – Unique silicon heating wires in extra silicon or Teflon insulation twice shielded with copper and foil to eliminate EMFs.
  11. Layer 11 – Thermostat sensors measure temperature in the different multilayer structure points and report to the controller. It’s the current mat’s temperature that you can see on the controller display. The temperature sensors help to maintain a consistent heat level throughout the mat as set by the user. They are also a part of the overheat protection controller system.
  12. Layer 12 – Bimetal switches for emergency overheat protection with automatic power shut-off feature if the controller overheats protection system fails, and the mat heats up to 80°C or 176°F.
  13. Layer 13 – Cotton fabric laminated with yellow mud or red clay accumulating heat, discharging Negative Ions, naturally releasing Far InfraRed rays.
  14. Layer 14 – Charcoal fabric layer releasing Far InfraRed (FIR) Rays and Negative Ions, decomposing and deodorizing smell.
  15. Layer 15 – Pure aluminum foil FIR reflection blocks heat from being conducted downwards and assists other layers in distributing and continually releasing the heat evenly.
  16. Layer 16 – Non-woven fabric layer for heat absorption and preservation.
  17. Layer 17 – Compressed non-woven cotton padding for thermal protection and increased comfort.
  18. Layer 18 – Waterproof eco-leather or polyester peach skin fabric for durability, tension resistance, and protection from moisture, dirt, and wear.

QUICKSTART GUIDE

  1. Consult your health professional to make sure that you can use hot stones or FIR sauna. Take extra care if you do not tolerate heat well.
  2. Read the USER GUIDE, safety instructions, «use with caution», and contraindication sections to be sure that the mat is OK for you, especially if you will use it on high heat settings or sleep on it.
  3. Drink a lot of water, juices, herbal teas before, during, and after sessions, and replenish minerals such as calcium, potassium, sodium, magnesium, and others that may be lost with sweat or urine.
  4. Create a relaxing surrounding atmosphere.
  5. Put the mat on your bed or the floor with crystals facing up.
  6. If you have a regular connector, please connect the controller to the mat to fit snugly. If your device comes with an in-line connector, connect it so that the male plugs go inside the female pins. Then screw the connector so that it’s tight.
  7. Turn the controller ON and set the timer, only then set the max temperature to test the mat for an hour. Do not put the protector on the mat or lay on it during this time.
  8. Cover the mat ENTIRELY with a blanket to pre-heat the stones for 30-60 minutes to set level. If the mat is covered only PARTIALLY, it may cause different temperatures in different parts of the mat, sensors disruption, and controller malfunction.
  9. Do not move a lot on the mat, do not stand on it, do not bend it, and do not put your head on hot stones. While heating, NEVER put on the mat foam, rubber, yoga, camp pads, mats, other non-permeable covers, or too thick (more than one inch) plies of towels or heavy blankets. NEVER put any solid objects such as pillows, laptops, books, bags, controllers, etc., on the heating surface to avoid overheat, malfunction, and fire risks.
  10. If the mat is too hard for you, put some of the included pads or covers on the mat to cushion it and eliminate the crystals’ pressure. You may add more towels if necessary.
  11. Start with the mat on the lowest heat settings, 35–40°C or 96–112°F, and short sessions only for 15-20 minutes (do not forget to pre-heat the mat, it will be slightly warm); watch how your body reacts.
  12. If you enjoy shorter sessions and your body reacts well, move up to longer or more intensive and frequent sessions.
  13. Gradually increase the temperature by several degrees and session time by 5 minutes each other day, and only if you feel comfortable and want a more intensive experience.
  14. You should choose the length, intensity, and frequency of the sessions so that you feel comfortable and refreshed.
  15. You should also have some rest between the sessions and never start with more than three a week before you are better informed about how they influence you.
  16. You should not feel any discomfort — but if there is any, rest several days and restart with the temperature, length, and frequency set to the lowest possible.
  17. Unplug your controller from the wall socket always when not in use. But do not disconnect the controller from the mat more frequently than necessary to avoid the connection becoming loose.

CONTROLLER H-60N for Classic mats, pads, and belt

MediCrystal Infrared Heating Amethyst Mat 3

  1. Power ON/OFF Toggle Button – Push it to turn the mat ON/OFF. If the H-40N controller is used, when you turn it ON, the display
    will show 0H – it is the default heating mode with 12 hours auto shut-off, or it can show blinking lines — if so, please, activate the Timer and set session time. If static lines — are displayed, please press the power button again with some effort so that lines
    — start to blink on display , showing that the controller is ON and ready to choose the session time and temperature. If the H-60N controller is used, the power ON indicator  lights up when the Power button is pressed and the power is ON. The display may also show ON. You can set the session time and temperature.

  2. Timer Control Toggle Button – Select one of the 5 options shown on the Temperature/Timer display : 1H, 4H, 8H, or 0H for 1, 4, 8, or 12 hours heating session with auto shut-off when the time expires or -H for generating ions without any heating.

  3. Temperature and Timer Display – Switches into Temperature Mode when the Temperature Dial  is rotated. The display shows the current temperature in Celsius (30-70°C), flashes to the set temperature, then back again. When the temperature is set above 122°F (50°C) for longer than 3.5 hours, the auto-protection feature decreases it to a safe 113°F (45°C) level. When the auto safety feature is active, the display shows [ ]. When the heating program is over, the temperature display will show — indicating that Power is ON.
    In Timer mode, the display shows one of the 4 time settings 1H, 4H, 8H, or 0H chosen by the Timer Control Button . It may show OF or — when the time setting is over or if the connection between the controller and the mat is lost. Reconnect or add time to resume heating or push the Power Button to turn off the controller.
    It is not recommended to turn the automatic control heat safety system OFF. Still, if you need to use the mat at a higher temperature than 122°F (50°C) for longer than 3.5 hours, you can manually inactivate this system. Press and hold the timer button  for 5 seconds until the display  shows S-. Press and hold the timer button  for 5 seconds until the display shows SA to reactivate the auto-protection feature.

  4. Power ON Indicator – Lights up when the power ON.

  5. HEATING Operation Indicator – It is ON when the mat is heating, OFF when the set temperature is reached.

  6. Adjust Temperature Dial – Use to increase or decrease heat 30–70°C (86–158°F). The dial range is marked, indicating the desired temperature in °F.

The temperatures on display reflect the condition of the inner heating elements, not the mat’s surface, which can be 10-20°F lower (or even lower than this) if the mat is not covered with a thick blanket. Usually, if the ambient temperature is around 70°F, it takes half an hour to an hour for the mat to reach the maximum level (158°F, or 70°C) if covered with a thick blanket.

If the controller shows errors, the easiest way to solve the problem is to reset it.
Disconnect the plug from the socket first and then from the mat connection terminal. When you disconnect the plug from the mat, please always do it carefully with two hands, holding the connector with one hand while the other hand pulls the plug. Pull the plug out of the connector on the mat carefully as well. Do not pull it by the cable, or the connection between the mat terminal and the controller plug may become loose. After this, always first reconnect the controller to the mat tightly and then plug it into an electrical outlet again. Be sure that the socket has electrical power; this can be tested by using any other electrical device.

*MediCrystal® stone mattresses, mats, pads, belts, wraps, pillows can help you create a relaxing, soothing, and re-energizing environment to maintain your wellness, balance, sound sleeping, physical strength, and fitness and awaken the restfulness, comfort, and invigoration powers and energies. Together with exercises and a healthy diet, MediCrystal® products may supplement your daily activity and become an essential part of your healthy lifestyle, improving your ability to do everyday things and enhance your life experience. MediCrystal® products are not intended to diagnose, cure, treat, mitigate, or prevent any disease, illness, or medical condition or substitute medical treatment of any kind or affect the body’s structure or function. Information here is never to be construed as medical advice. It does not reflect or represent a product claim. FDA has not approved or evaluated MediCrystal® products or this information. All products, specifications, and data are subject to change without notice to improve the products’ reliability, function, or design.

WARNING : If your mat is rated for the North American 110-120V voltage and your controller is with the U.S. standard NEMA 5-15P (two-pole with ground pin) plug, use it only with the step-down 220-250V to 110V voltage converter in the 220-250V 50Hz countries. The maximum wattage of such converter should be at least 2-3 times higher than the mat’s power consumption. Do not connect the 110-120V mat into the 220-250V outlet through an adapter. If you plug in a device that isn’t rated for the outlet’s voltage, it may be severely damaged and cause fire risks!

All products, controllers, specifications and data, and a set of items packaged in a box are subject to change without notice to improve the devices’ reliability, function, or design.
Please, check for the details of the most updated products at the www.MediCrystal.com website.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals