PROCORE® PLUS HERRINGBONE INSTALLATION INSTRUCTIONS
Quick Reference:
-
Concrete moisture requirement
- For all on and below grade concrete, use a 6-mil (0.006-in.) Polyethylene (PE) sheet or
equivalent
- For all on and below grade concrete, use a 6-mil (0.006-in.) Polyethylene (PE) sheet or
-
Flatness tolerance
- < 1/8-in. over 6-ft. and 1/16-in. over 1-ft. in all directions
-
Installation temperature
- Between 60°F to 80°F (16°C to 27°C)
-
Optimal service temperature
- Between 40°F to 90°F (4°C to 32°C)
-
Additional acoustic underlayment
- Not required or recommended
-
Expansion gap (entire perimeter)
- 1/4-in. ≤ 50-ft., and 1/2-in. between 50 – 85-ft. lengths or widths
-
Expansion joints (large areas)
- Only required if > 85-ft. in length or width
-
3-IN-1 doorway transition
- Not usually required
-
3-Season rooms
- Acceptable (but see “Expansion Gap”)
-
Pet stain warranty
- Yes, but immediately clean up when discovered
General Information & Limitations:
Please watch the installation videos available at Lowes.com. This flooring has
a high-density core (HDC), designed to be installed in indoors only, as a
“floating floor” for residential applications. The optimal operating
temperature is between 40°F to 90°F (4°C to 32°C). Avoid prolonged exposure to
direct sunlight or other heat sources where temperatures will exceed 90°F
(32°C), as damage may occur. This product is not suitable for heavy rolling
loads. Rolling chairs with soft or W-type casters and a maximum rolling weight
of 250 lbs. are acceptable, provided that a polycarbonate chair mat is used to
protect the flooring in rolling chair areas. Do not secure flooring or
furniture to the substrate with mechanical fasteners or adhesives. Do not
install cabinets, kitchen islands, or other non-movable furniture on top of
this floor covering. Contact the technical department at
1-888-509-3438 or techsupport@novalis-
intl.com for assistance. Copies of ASTM documents are available for purchase
at www.astm.org.
Recommended Tool List:
Appropriate Personal Protective Equipment (PPE) including safety glasses,
gloves and suitable dust mask. Appropriate tools to prepare the substrate,
HEPA filtered vacuum, 6-ft. and 1-ft. straight edge or level, two quarters
(U.S. coins), tape measure, pencil, speed square, utility knife with blades,
1-lb. (∼ 16-oz.) rubber or soft faced dead blow hammer (preferred) or rubber
mallet, chalk-line, pull-bar, Oscillating Multi-Tool or hand saw (door jambs),
wedge spacers or similar, jigsaw with carbide blades, knee pads. If required,
use a super-glue liquid adhesive for any small pieces.
Warning:
All local, state, and federal regulations must be followed; this includes
the removal of in-place asbestos (floor covering and adhesive) and any lead-
containing material. The Occupational Safety and Health Administration (OSHA)
has exposure limits for people exposed to respirable crystalline silica; this
requirement must be followed. Do not use solvent or citrus-based adhesive
removers. When appropriate, follow the Resilient Floor Covering Institute’s
(RFCI) Recommended Work Practice for Removal of Existing Floor Covering and
Adhesive. Always wear safety glasses and use respiratory protection or other
safeguards to avoid inhaling any dust. The label, installation, and
maintenance instructions along with the technical data sheet, limited warranty
and any appropriate Safety Data Sheet (SDS) of all products must be read,
understood, and followed before installation commences. If the substrate or
subfloor fails for any reason, then the floor covering limited warranty is
void.
Do not leave spills unattended – wipe up promptly, and allow the floor
covering to dry before trafficking. Use bathmats and install safety handrails
where this floor covering is used next to wet or barefoot areas, like showers
and baths.
Documentation:
Record and file the measured and observed site conditions and test results,
including all photographs and corrective measures. Maintaining this
documentation, along with the original invoice and any labor receipts
throughout the warranty period, is recommended, as this will be required in
the unlikely event of a claim.
Site Conditions:
The prepared installation area must be fully enclosed and weather tight.
During the installation, any direct sunlight should be blocked using blinds,
drapes or other protection. The ambient temperature during installation must
be > 60°F (16°C), with a recommended maximum of 80°F (27°C) (see figure 1).
Note:
When installed at temperatures > 80°F (27°C), the size of an expansion gap
will increase when the floor covering is cooled.
Flatness:
Check all substrates for flatness prior to installation. The maximum
acceptable tolerance is < 1/8-in. gap (2 x US quarters) over 6-ft. and ≤
1/16-in. gap (1 x US quarter) over 1-ft. (see figure 2). Make any necessary
adjustments to the substrate before installation. Dormant cracks saw cut
joints and grout lines < 1/8-in. wide or deep are acceptable – all others must
be cleaned of all dirt and debris, then filled using a suitable commercial-
grade patching or repair compound, following the product instructions.
Concrete Substrates:
All concrete must be free of contaminates and structurally sound. If required,
smooth the surface using a suitable, moisture-resistant commercial-grade
leveling or patching compound, following the product instructions. Do not
install if hydrostatic pressure is visible, present, or suspected. If a
chemical adhesive remover has been used, contact the technical department. For
all on and below-grade concrete slabs, test the surface to confirm it is
absorbent (porous), following the ASTM F3191 Standard Practice for Field
Determination of Substrate Water Absorption (Porosity) for Substrates to
Receive Resilient Flooring. The water droplets placed on the substrate must be
absorbed for it to be considered absorbent. If required, the concrete can be
made porous by mechanical methods, such as diamond grinding, a DiamaBrush
buffer attachment, shot-blasting or similar.
Concrete Moisture:
For all on and below-grade concrete slabs, use a ≥ 6-mil thick polyethylene
(PE) sheet, available at Lowe’s (see figure 3). Sheeting must be installed
over the entire area and extend at least 2-in. up the walls. All seams must be
overlapped and taped according to the product instructions. The liability and
warranty for any product’s performance remain with its manufacturer.
Wood Substrates:
All wooden substrates and substrates must be dry and in compliance with the
moisture content percent (MC-%) for your region. Regional values are freely
available by searching “moisture map of wood” images. Test using a non-
destructive electronic moisture meter, following the product instructions.
The substrate must comply with local building codes, have at least 18-in. of
well-ventilated air space below and have a suitable vapor retarder to isolate
the substrate from ground cover and outdoor conditions. Wood substrates must
have a total thickness of at least 1-in. Sleepers must not make direct contact
with concrete or earth. If necessary, install an underlayment grade plywood
with a minimum thickness of 1/4-in. on the surface. The underlayment must be
installed in the opposite direction to the substrate, following ASTM F1482
Standard Practice for Installation and Preparation of Panel Type Underlayments
to Receive Resilient Flooring.
Note:
plywood is a water-sensitive substrate that may become damaged or deformed by
topical liquids. To protect wood substrates from topical water exposure,
follow the Wet Area Guidelines below.
Additional Acoustic Underlayments:
Additional acoustic underlayments are not recommended or required. However,
should one be used, ensure a polycarbonate chair mat is used in all rolling
chair areas. Do not use additional acoustic underlayments in any commercial
areas.
Unsuitable Substrates:
These include but are not limited to: any floating or loose floor coverings,
hardwood, carpet, cushion vinyl, rubber, cork, foam, asphalt tile, any
additional acoustic underlayment, any substrate with visible mold, mildew, or
fungi and any substrate in wet areas, such as inside showers and saunas. Do
not install directly over any adhesive or adhesive residue of any kind. Do not
install directly over a radiant heated substrate or in recreation vehicles,
campers or boats.
Note:
Existing hardwood floor coverings will swell when exposed to moisture: vinyl
floor covering may restrict the movement of moisture in hardwood, which may
result in flooring failure, especially when installed on or below grade. Some
hardwood floor coverings may also discolor vinyl floor covering, which is
excluded from warranty coverage. Electing to install over any existing floor
covering releases the manufacturer from any responsibility regarding the
suitability and continued performance of that product, including any resulting
effect on the new floor covering, such as indentations and damaged locking
mechanisms.
Other Subfloors/Substrates:
These may be acceptable. However, they must be and remain dry, without
contaminants and be structurally sound.
Wet Area Requirements:
Some substrates, such as plywood, may be sensitive to and damaged or deformed
by topical liquids, such as water, pet urine, and spills. While ProCore Plus
Herringbone is a waterproof product, water-sensitive substrates may require
additional protection to prevent water exposure. When installing floor
covering in wet areas, ensure that bathmats or similar are used where
appropriate to decrease the amount of water that can collect on the surface.
Any and all spills should be cleaned up immediately after discovering them and
within 8 hours. Substrate flatness is critical to preventing water migration
through seams that may flex or peak due to foot traffic and substrate
deflection – be sure to check the flatness and make all necessary adjustments
prior to installing. The water-sensitive substrate must have a ≥ 6-mil thick
polyethylene (PE) sheet (available at Lowe’s) installed over the entire area
and extend at least 2-in. up the walls. All seams must be overlapped and taped
according to the product instructions. In addition, the area must be separated
from all other rooms using suitable water-resistant t-molding. Following
flooring installation, the plastic sheet must be trimmed flush with the
surface of the substrate. Prior to installing the wall base or molding, the
required perimeter expansion gap must be filled with a 100% silicone caulk,
including the wet area side of all t-moldings. Additionally, all door jambs,
plumbing, and vertical surfaces that won’t have wall base or molding installed
must be sealed with 100% silicone caulk. Once the entire perimeter has been
filled or sealed, a water-resistant wall base, moldings, or other accessories
may be installed. Apply a bead of silicone caulk to the parts of the wall base
or moldings that will make contact with the surface of the flooring. Ensure
all wall bases and moldings are attached to the substrate, wall, or wall base
without compression, to allow movement and cleanup of any remaining silicone
immediately. Do not anchor wall base or moldings into or through the floor
covering.
Expansion Gap:
If the length or width of the installation area is ≤ 50 ft., an expansion gap
of at least 1/4 in. must be created around the entire perimeter. If the
overall length or width is between 50 – 85 ft., then the gap must be increased
to 1/2 in. around the entire perimeter. A maximum of 85 ft. in length or width
must not be exceeded (see figure 4). If required, use a suitable trim molding
covering the edges by 1/8-in. and allowing a 1/2-in. expansion gap. For three-
season rooms, a gap of at least 1/2 in. around the entire perimeter is
required. In addition, the area must be separated from all other rooms using
suitable trim molding. The maximum of 30 ft. in length or width must not be
exceeded.
Note:
Areas with very heavy furniture ≥ 800-lb. (363-kg) must be isolated from the
rest of the installation with a compatible t-molding and have ≥ 1/2-in.
expansion gap.
General Preparation:
It is recommended to remove all wall-base before flooring installation.
Alternately, a quarter-round molding (fixed to the wall or wall base only)
covers both the required expansion gap and at least 1/8 in. of the floor
covering may be installed. Undercut all wooden door jambs and the first in. of
any remaining wall base (later covered with molding) with an Oscillating
Multi-Tool or hand saw – the height must be the thickness of the floor
covering plus 1/64-in., which allows the floor covering to expand and contract
freely, out of sight, with temperature fluctuations (see figure 5). Steel door
jambs should be pattern-scribed, leaving the required expansion gap. Use a
color-coordinated 100% silicone to fill the void. Clean the entire area to be
installed using a HEPA-filtered vacuum. Before beginning, check and make sure
the lot numbers on the packaging match and mix the floor covering from several
boxes to ensure a random appearance. During the installation, inspect for
visible defects, including any damage, gloss, color or shade variations, dirt,
and debris in the locking mechanism (remove using a soft brush), as installing
it assumes full responsibility. If you have any concerns, do not install it
and immediately contact the technical department.
Layout:
Follow the design or drawings provided or agreed upon by the designer,
architect, or end-user. Rigid Core Herringbone can be installed in a standard
herringbone (see figure 6) or square herringbone pattern (see figure 7) – be
sure to follow the appropriate Starting Line instructions, depending on which
pattern is specified or desired.
Starting Line – Standard Herringbone:
Determine the required direction of the layout – along the length of the area
is recommended. Measure, calculate and mark (pencil) the substrate at each end
of the room. Use a chalk-line to mark the center line of the installation –
this will serve as the starting line.
Starting Line – Square Herringbone:
Determine the required direction of the layout – along the length of the area
is recommended. Measure, calculate and mark (pencil) the substrate at each end
of the room. Use a chalk line to mark the center line of the area. Measure,
calculate and mark the center of the center line. Use a chalk line and speed
square to create a 45-degree line from the intersection of the center lines
and the wall, extend your chalk line to mark the substrate across the entire
width of the area – this will serve as the starting line.
First Rows:
Using the starting line as a reference, determine which direction the “arrow”
pattern of the herringbone will face. Once determined, install the first two
rows, using full planks only. Select a starting piece and place it on the
substrate so that it is at a 45-degree angle to the left of the starting line
against the wall. The top left corner of the piece should align with the
starting line and the bottom left corner should be about 1 ft away from the
wall. Using a second piece of material, insert the side without an extended
locking mechanism (tongue) into the top of the starting piece at a ~25° angle.
Make sure the piece is properly seated, then lay the second piece flat and
engage the locking mechanism. Complete the full pieces of the first two rows
using this method, alternating sides, to create an arrow. Check the length of
the “cut piece” at the end and adjust the rows to balance the installation
(avoid small cuts if possible). These rows may move during this process, so
check and make sure they are straight and correctly on your starting line.
Place several unopened cartons of material along the starting rows, to prevent
excessive movement during the installation of subsequent rows.
Subsequent Rows:
Continue the installation of the field one row at a time on either side of the
starting rows. Ensure each row is installed in an “arrow” pattern and not a
“V” pattern.
Cutting:
To cut the floor covering, measure and mark the surface with a pencil, then
carefully score the surface a few times on the mark using a sharp utility
knife along the side of a speed square (see figure 8). Snap the plank
downwards and complete by cutting the backing from underneath (see figure 9).
For complicated cuts, such as door jambs, it is recommended to use a jigsaw
with a carbide blade following the product safety instructions.
Backfilling:
To backfill the end cuts, start with the next piece (the largest) in the
installation pattern based on the adjacent pieces. Measure and cut the piece
to fit, accounting for the proper expansion gap. Insert into the previous row
at a ~25° angle and make sure it is properly seated. Use a pull bar and dead
blow hammer or rubber mallet to tap the backfill piece into the adjacent place
and engage the locking mechanism. Ensure all locking mechanisms of the
backfilled piece are fully engaged before installing subsequent backfill
pieces.
Pro-Tips:
Do not hit the locking mechanism directly with any hammer, tapping block or
pull bar (except for cut pieces) – doing so will damage the locking mechanism
and may result in peaking, gapping or broken joints. If required, use a ∼
6-in. piece of scrap floor covering, seated in the locking mechanism, to
lightly tap and close any joints. If you need to install small cuts of floor
covering that are < 3-in. in length or width, place a thin bead of liquid
superglue on the previously installed locking mechanism just before
installing. This will ensure the pieces remain locked together during use. Do
not get the adhesive on the surface – coverage will be ∼ 30 ft. per oz.
Completion:
If used, plastic sheeting must be trimmed flush with the surface of the floor
covering. If installed in a wet area, plastic sheeting must be trimmed flush
with the substrate. When installing in wet areas, ensure the expansion gap and
all vertical surfaces are filled or sealed with a 100% silicone caulk, and
ensure all wall-base and moldings are water-resistant, following the Wet Area
Guidelines. Install all necessary wall bases and/or moldings and ensure they
are anchored to the substrate, wall, or wall base without compression, to
allow movement. Do not anchor wall base or moldings into or through the floor
covering.
Protection:
If required, protect the clean floor covering from other trades or heavy loads
using ½-in. plywood or similar and tape all seams. For light traffic, use a
Ram board or similar and tape all seams. For furniture, use only polyurethane,
silicon or felt glides (replaced > 3 times a year), keeping them clean and
grit-free – all glides should be ≥ 1-in.2, especially on heavy furniture. Use
protective polycarbonate chair mats designed for resilient flooring underneath
rolling chairs or soft “W-type” wheels. Use non-rubber-backed entrance matting
at all outdoor entrances, as this will improve air quality and reduce
maintenance. Do not drag heavy or sharp objects directly across the surface –
use hard surface “sliders” (available at Lowe’s). For areas that may be
subjected to standing water on the surface, such as bathrooms with a bath or
shower, the perimeter of the installation must be properly sealed using 100%
silicon caulk to prevent water from getting beneath the flooring. To avoid
excessive fading or discoloration from direct sunlight exposure, use
appropriate window treatments, an effective UV/IR film or Low-E glass windows.
Take photographs and have any required documentation signed and filed
following completion.
PROCORE® 3-IN-1 TRIM MOLDING
General Information:
If the overall length of the area is over 85 ft. in either direction, if
temperatures are expected to exceed 90°F (32°C), like in 3-season rooms, or if
a transition is desired, a 3-In-1 trim molding should be installed. 3-in-1
trim moldings are color-coordinated and available at Lowe’s.
Note:
Colors and patterns that have a high color variance won’t match perfectly.
INSTALLATION INSTRUCTION FIGURES
Manufactured by Novalis Intl.
P: 888-509-3438
E: techsupport@novalis-intl.com
procorefloors.com
Revised on: 11.22.21