LF010 Sound Level Limiter
“`html
Specifications
-
Model: LF010
-
Functionality: Sound level limiter, Spectrum analyser, Register
by 1/3 octave band -
Access: Webserver
-
Language: English
Product Usage Instructions
DIRECT MODE ACTIVATION
To access the webserver, follow these steps:
- Activate Direct mode on the LF010 touch screen.
- Go to the main menu to begin communication.
- Exit Direct Mode by pressing or after 60 minutes of
inactivity.
WEBSERVER LOGIN
Follow these steps to log in to the webserver:
-
Choose User, Installer, or Inspector access.
-
Use ‘admin’ as the initial password for User and Installer
access (password can be changed later). -
No password is required for Inspector access.
OTHER WAYS TO ACCESS THE WEBSERVER
If connected to a local network (Ethernet or WIFI), follow these
steps:
-
Access the webserver without activating Direct mode.
-
Configure the limiter’s connection to the local network as per
the manual. -
Ethernet communication with a Windows PC is possible without
Direct mode.
Note: Remember to check the IP address settings
on both the PC and the LF010 limiter.
LF010 LIMITER MANUAL
Once in the webserver, you can download the LF010 limiter manual
from the SUPPORT option.
FAQ
Q: How can I change the password for User and Installer
access?
A: You can modify the password later in the SUPPORT option of
the webserver.
Q: What should I do if I encounter communication issues while
in Direct Mode?
A: Ensure that there is no inactivity for more than 60 minutes
to maintain communication.
Q: Can I access the webserver without using an external
device?
A: No, access to the webserver requires an external device with
a web browser.
“`
LF010
QUICK GUIDE TO THE WEBSERVER OF THE LF010 LIMITER
G_LF010_v0005_20231102_EN
Sound level limiter Spectrum analyser and register by 1/3 octave band
DIRECT MODE ACTIVATION
Access to the webserver is done with an external device that has a web browser: desktop or laptop computer, tablet, smartphone, etc.
The first access to the webserver must be done by activating the “Direct mode” of the limiter, to do this:
· Access the “Main Menu”
on the LF010 touch screen.
· Press the “Direct Mode” icon
in the main menu.
· The LF010 activates the direct mode of communication by generating a WIFI wireless communication.
Communication ends when you exit the “Direct Mode” by pressing or after 60
minutes of inactivity.
To communicate the desired device (PC, tablet, smartphone …) with the LF010
limiter follow the next steps:
· Search for WIFI networks with the device you want to connect to the LF010
limiter.
· Select the WIFI network that generates the LF010 limiter; The name of the
WIFI network is displayed on the LF010 “Direct mode” screen.
· Connect the device to the WIFI network (no password required). If the
operating system reports that this network does not allow access to the
Internet, indicate that you want to maintain the connection.
· Finally open an Internet browser and write in the address bar the IP address
(WIFI) shown on the LF010 “Direct mode” screen or enter “lf010.info”.
WEBSERVER LOGIN
The webserver login screen will appear where you must choose whether you
access as “User”, as “Installer” or as “Inspector”.
The initial password for “User” and “Installer accesses is “admin”. This can
be modified later (consult the manual in the SUPPORT option of the webserver).
For “Inspector” access, no password is required.
EN
Maracaibo, 6
T. (34) 934 335 240 info@cesva.com
08030 Barcelona (Spain) F. (34) 933.479.310 www.cesva.com
LF010
QUICK GUIDE TO THE WEBSERVER OF THE LF010 LIMITER
EN
Sound level limiter Spectrum analyser and register by 1/3 octave band
OTHER WAYS TO ACCESS THE WEBSERVER
If the LF010 limiter is connected to a local network (Ethernet or WIFI), the
webserver can also be accessed through it without activating the direct mode’. To configure the connection of the limiter to the local network consult the manual (you will find in the SUPPORT option of the webserver). It is also possible to make an Ethernet communication between the limiter and a Windows PC without activating the
direct mode’, to do this:
· Connect the Ethernet cable between the LAN (RJ45) connectors of the LF010
and the Windows PC.
· Select the “LF010 Status” icon on the limiter touch screen and check the IP
address that appears under the “Ethernet” option.
· Finally open an internet browser and enter the IP address consulted in the
previous step.
NOTE**: The PC must have the “Obtain IP address automatically” option selected in its Ethernet properties. The LF010 limiter must have the auto IP option programmed.
NOTE: This method allows you to access to the LF010 webserver and
simultaneously navigate through the different options of the LF010 without
losing communication.
LF010 LIMITER MANUAL Once you have entered the webserver, you can download the
LF010 limiter manual in the SUPPORT option of the webserver.
Maracaibo, 6
T. (34) 934 335 240 info@cesva.com
08030 Barcelona (Spain) F. (34) 933.479.310 www.cesva.com
References