Shenler RFT Industrial Control Relay Interface Relay Owner’s Manual
- September 16, 2024
- Shenler
Table of Contents
Shenler RFT Industrial Control Relay Interface Relay
Product Specifications
- Series Name: RFT Interface Relay
- Contact Form: 1 pole 12A; 2 pole 8A
- LED: Non-polarity integrated in relay (AC red, DC green)
- Test Button: Lockable with color identification for coils (AC red/DC blue)
- Bus Jumper: Extends the circuit
- Coil Material: Top copper coil for reliability and endurance
- Contact Material: Silver alloy for increased current carrying capacity
- RoHS Directive Compliant
Product Usage Instructions
Installation
Follow these steps to install the industrial control relay:
- Ensure power is switched off before installation.
- Select the appropriate socket configuration based on your requirements.
- Connect the relay module to the socket.
- Verify proper terminal arrangement for plug-in.
Testing
Use the test button for on-site testing:
- Press the test button to check the functionality of the relay.
- Observe the LED indicators for working status (AC red, DC green).
Maintenance
Regular maintenance can ensure optimal performance:
- Clean the inspection window for clear visibility.
- Check for any loose connections or signs of wear on contacts.
- Inspect the bus jumper for proper extension of the circuit.
Frequently Asked Questions (FAQ)
-
Q: What are the different options available for the industrial control relay?
A: The options include standard type, LED, diode, cover with flange, gold plated contact, and various combinations of these features. -
Q: What is the electrical durability of the relay?
A: The relay has high electrical durability with up to 20 x 10^4 cycles at high temperature and frequency 1s on, 5s off. -
Q: How can I identify the coil voltage code?
A: Refer to the provided table for voltage codes corresponding to different AC and DC voltages.
Selection manual of industrial control relay
RFT
Interface Relay
- Slim and compact size
- 1 pole 12A; 2 pole 8A
- With non-polarity LED integrated in relay
- With lockable test button and inspection window
- Identification of coils through test button color (AC red/DC blue)
- Conformity with RoHS Directive
Characteristics
Configuration| 1C| 2C
| Load Resistance| 12A/250VAC, 30VDC| 8A/250VAC, 30VDC
Contact
| Motor load| 1/3HP, 240VAC| 1/6HP, 240VAC
Max. switching capacity (resistive)| 3000VA, 360W| 2000VA, 240W
Min. switching capacity| 170mW(17V/10mA)
Initial contact resistance| ≤50mΩ
Material| Ag alloy
Electrical durability (high temp., frequency
1s on, 1s off)
| ≥20 x 104Cycles (1800 Ops/h)
Electrical durability (normal temp., frequency
1s on, 5s off)
| ≥30 x 104Cycles(600 Ops/h)
Mechanical durability| ≥2000 x 104Cycles (18000 Ops/h)
Pick-up voltage (23℃) (Rated voltage)| DC:≤75% ,AC:≤80% 50/60Hz
Drop-out voltage (23℃) (Rated voltage)| DC:≥10% ,AC:≥30% 50/60Hz
Maximum voltage (23℃)(Rated voltage)| 110%
Insulation resistance| ≥1000MΩ (500VDC)
Coil operating power| DC(W)| approx. 0.53
AC(VA)| approx. 1.0(60Hz)
Operate time (at nominal voltage)| ≤20ms
Release time (at nominal voltage)| ≤10ms
Initial breakdown voltage| Between open contacts| 1000VAC/1min (leakage
current 1mA)
Between poles| 3000VAC/1min (leakage current 1mA)
**** Between contacts and coil| 5000VAC/1min (leakage current 1mA)
Insulation characteristics
IEC 60664 UL840
| Rated voltage| 250VAC
Pollution level| 3
Overvoltage level| III
Impulse withstand voltage (waveform: 1.2/50μs)| 4000V(Altitude 2000m)
Coil resistance: under coil voltage 110V are measured with tolerance of ±10%Ω, above 110V with tolerance of ±15%Ω.
Contact Specification
Dimensions (mm)
Wiring Diagrams
Documents / Resources
|
Shenler RFT Industrial Control Relay Interface
Relay
[pdf] Owner's Manual
RFT Industrial Control Relay Interface Relay, RFT, Industrial Control Relay
Interface Relay, Control Relay Interface Relay, Relay Interface Relay,
Interface Relay, Relay
---|---