Honeywell Resideo VNT5150H1000 HRV/ERV Filter Replacement Kit Instructions
- September 11, 2024
- Honeywell Resideo
Table of Contents
Honeywell Resideo VNT5150H1000 HRV/ERV Filter Replacement Kit
Cleaning or Replacing Instructions
Filter Replacement Kit HRV/ERV
- VNT5150H1000 / VNT5150E1000 Part N° 50055113-009
- VNT5200H1000 / VNT5200E1000 Part N° 50055113-010
- VNT5070H1000 / VNT5070E1000 Part N° 50055113-026
READ AND SAVE THESE INSTRUCTIONS
Read all instructions and WARNINGS carefully before beginning.
WARNING: Risk of electrical shocks. Before servicing or cleaning the HRV/ERV system, always disconnect the unit from its power source.
-
Four times a year or as needed, vacuum the filters.
-
Replace the filters once a year.
Note: The model VNT5070 has all ports on top of the ventilator. -
STEP 1 : Disconnect the power supply.
-
STEP 2 : Unlatch the door panel.
-
STEP 3 : Remove the door panel by sliding it off the hinges.
-
STEP 4 : Remove the filters and vacuum. (Figures 1 and 2) (Skip this step if you are replacing the filters.)
-
STEP 5:
- HRV MODEL: Once a year or as needed, slide out the heat recovery core. Vacuum the four surfaces, let soak in warm water for 15 minutes, then spray rinse and let dry. (Figure 3)
- ERV MODEL : Once a year or as needed, slide out the energy recovery core. Vacuum the ERV core or rinse with cold water. Do not use soap, a dishwasher, or a pressure washer. (Figure 3)
-
STEP 6 : Once a year or as needed, clean the interior of the unit (walls and drain pan) with a mild non-abrasive soap. It is recommended to use environmentally friendly products. (Figure 4)
-
STEP 7 : Replace Core.
-
STEP 8 : Replace and dispose of the old filters under your municipal guidelines.
-
STEP 9 : Reinstall and latch door panel.
-
STEP 10 : Connect the power supply.
-
Note: The model VNT5070 has all ports on top of ventilator.